ページ1に含まれる内容の要旨
P RO W ALL V ENTILATION H OODS
INSTALLATION INSTRUCTIONS
ページ2に含まれる内容の要旨
CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip- ment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if pr
ページ3に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS INSTALLATION REQUIREMENTS IMPORTANT NOTE: This installation must be LIST OF MATERIALS completed by a qualified installer or Wolf The following is a list of materials shipped authorized service center technician. with the Wolf Pro wall ventilation hood. Installer: Please read the entire Installation Low-Profile Wall Hood Instructions prior to installation. Save these Stainless steel wall hood instructions for the local inspector’s refer- ence, then leave them with
ページ4に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS INSTALLATION CONSIDERATIONS Wolf Pro wall ventilation hoods are IMPORTANT NOTE: Wolf recommends that recommended for use with all Wolf cooking the Pro wall ventilation hood be installed appliances. 30" (762) to 36" (914) above the countertop. IMPORTANT NOTE: For optimal performance, Rail option (R) wall hoods come with a classic a Pro 27" (686) deep wall hood is recom- stainless steel decorative rail and stand-offs. ACCESSORIES mended for use with ranges and range
ページ5に含まれる内容の要旨
INSTALLATION INSTRUCTIONS OVERALL DIMENSIONS LOW-PROFILE WALL HOODS 12" (305) 3 /4" (19) Overall Widths 30" (762), 36" (914), DIAMETER OF RAIL 42" (1067) and 48" (1219) 10" (254) OVERALL HEIGHT 4" (102) Overall Height 10" (254) Overall Depth (excluding rail) 22" (559) OVERALL WIDTH 22" (559) 2" OVERALL DEPTH (51) Shipping Weight (shell only) 39–55 lbs (18–25 kg) Low Profile Wall Hood shown with (R) rail option 1 Dimensions may vary to ± /8" (3). 12" (305) 24 " (610) DEEP WALL HOODS 3 /4" (
ページ6に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS INSTALLATION SPECIFICATIONS Low-Profile and 24" (610) Deep 6" LOCATION OF ELECTRICAL E Wall Hoods (152) 5" (127) 10" (254) 18" (457) HEIGHT OF HOOD WIDTH OF HOOD 30" TO 36" 30" TO 36" 22" (559) (762–914) (762–914) 24" (610) TO COUNTERTOP TO COUNTERTOP DEPTH OF HOOD NOTE: Low-profile and 24" (610) deep wall hoods have a vertical or horizontal discharge; discharge direction varies with blower model. 27" (686) Deep Wall Hoods 6" LOCATION OF ELECTRICAL E (152) 5" (12
ページ7に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INSTALLATION SPECIFICATIONS Low-Profile Wall Hoods The following chart provides dimensions specific to each wall hood model. These Model (A) (B) (C) (D) dimensions are critical for proper installation. 1 11 W302210I 30" (762) 7 /2" (191) 15" (381) 4 /16" (119) Also refer to the illustration below. 1 11 W362210I 36" (914) 7 /2" (191) 18" (457) 4 /16" (119) 1 11 W362210 36" (914) 7 /2" (191) 18" (457) 4 /16" (119) 1 11 W422210 42" (1067) 7 /2" (191) 21" (533) 4 /16" (119)
ページ8に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS LOW-PROFILE AND 24" (610) HOODS STEP 1: INSTALL DUCTWORK DUCTWORK INSTALLATION THROUGH ROOF To reduce the risk of fire, use only metal ductwork. ROOF CAP OR REMOTE BLOWER – TRANSITION FROM 8" (203) TO 10" (254) DUCT REQUIRED FOR REMOTE BLOWER 8" ROUND DUCT IMPORTANT NOTE: Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop. SOFFIT OR CABINET TRANSITION 3 1 OR DUCT COVER 17 /4"W x 4 /4"D TO 8" ROU
ページ9に含まれる内容の要旨
INSTALLATION INSTRUCTIONS LOW-PROFILE AND 24" (610) HOODS Always install a roof or wall cap if you are not installing a remote blower. Connect 8" (203) DUCTWORK INSTALLATION round metal ductwork for low-profile hoods or THROUGH ROOF 10" (254) round metal ductwork for 24" (610) deep hoods to the cap and work back towards ROOF CAP OR REMOTE BLOWER the hood. Use duct sealing tape on joints between ductwork sections. 10" ROUND DUCT IMPORTANT NOTE: Do not use ducting TRANSITION 1 22 /4"W x 9"
ページ10に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS LOW-PROFILE AND 24" (610) HOODS STEP 2: WALL PREPARATION Refer to the illustrations below for the location of mounting holes for the low-profile and 24" (610) deep wall hoods. Framing must be tied together and to IMPORTANT NOTE: Wolf recommends ceiling joists to provide enough structural installing the internal blower to the rough-in ACCESSORIES strength to support the weight of the plate prior to mounting the hood. hood and internal blower, if applicable. If you
ページ11に含まれる内容の要旨
INSTALLATION INSTRUCTIONS LOW-PROFILE AND 24" (610) HOODS Separate the transition from the rough-in Horizontal discharge requires a wall cut-out. plate by removing the four shipping screws. Refer to the illustrations below. The location Do not discard the screws; they will be of the cut-out is determined by the installa- needed to reinstall the transition to the tion height of the hood. rough-in plate. If you are installing an in-line or remote 7 Determine the direction of discharge for blower,
ページ12に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS LOW-PROFILE AND 24" (610) HOODS STEP 5: INSTALL THE HOOD COMPLETE THE INSTALLATION IMPORTANT NOTE: If a backsplash is to be To complete the installation for the low-profile used, it should be installed before the wall and 24" (610) deep wall hoods, follow Step 6: hood is mounted. Install Wiring and refer to information on pages 17–19 for internal, in-line and remote Align the hood assembly with the marked blowers. location. Follow instructions to install the filte
ページ13に含まれる内容の要旨
INSTALLATION INSTRUCTIONS 27" (686) DEEP WALL HOODS STEP 1: INSTALL DUCTWORK DUCTWORK INSTALLATION THROUGH ROOF To reduce the risk of fire, use only metal ductwork. ROOF CAP OR REMOTE BLOWER 10" ROUND DUCT IMPORTANT NOTE: Wolf recommends that the Pro wall ventilation hood be installed TRANSITION 1 30" (762) to 36" (914) above the countertop. 22 /4"W x 9"D TO 10" ROUND SOFFIT OR CABINET 10"H (INCLUDING FLANGES) OR DUCT COVER VERTICAL DISCHARGE IMPORTANT NOTE: Consult a qualified HVA
ページ14に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS 27" (686) DEEP WALL HOODS STEP 2: WALL PREPARATION The hood assembly is shipped with the rough-in plate/transition attached. The transition is shipped upside down in the top of the hood. It must be removed and rein- Framing must be tied together and to stalled in the proper position. ceiling joists to provide enough structural ACCESSORIES strength to support the weight of the Remove the filters by pushing each filter up hood and internal blower, if applicable. at
ページ15に含まれる内容の要旨
INSTALLATION INSTRUCTIONS 27" (686) DEEP WALL HOODS If you are installing WBLOWER-90INT or STEP 5: INSTALL THE HOOD WBLOWER-120INT, refer to the internal IMPORTANT NOTE: If a backsplash is to be blower information on page 17 and follow used, it should be installed before the wall installation instructions provided with the hood is mounted. blower. Align both ends of the hood assembly with If you are installing an in-line or remote the ends of the rough-in plate. Refer to the 7 blower, drill a /8
ページ16に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS PRO WALL VENTILATION HOODS STEP 6: INSTALL WIRING Remove the electrical box cover from the rough-in plate. Connect black wire to power supply black wire, white wire to power supply white wire and green wire to green This ventilation hood must be properly wire or bare wire. grounded. This unit should be installed by IMPORTANT a qualified electrician in accordance with Place all wiring connections inside the elec- NOTE all applicable national and local electrical tr
ページ17に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INTERNAL BLOWERS IMPORTANT NOTE: Refer to the specific Verify that the blower discharge aligns with installation instructions provided with each the discharge cut-out in the back panel of internal blower for additional mounting and the hood. wiring instructions. Install the hood rough-in plate with blower IMPORTANT NOTE: Use wire connectors or assembly to the wall. Secure the power wire nuts approved by UL or C/UL. cord(s) without damaging or pinching while installing t
ページ18に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS IN-LINE AND REMOTE BLOWERS BLOWER INSTALLATION Be sure that there is enough space for any transitions that may be needed between the IMPORTANT NOTE: Refer to the specific blower and the connecting ductwork. For best installation instructions provided with each performance, locate transitions nearest the blower for additional mounting instructions. blower. ACCESSORIES Locate the blower so that the length of the Refer to the illustrations below and on the duct run a
ページ19に含まれる内容の要旨
INSTALLATION INSTRUCTIONS IN-LINE AND REMOTE BLOWERS BLOWER WIRING Plug the cord assembly into the receptacle located near the center of the hood shell. IMPORTANT NOTE: Refer to the specific Use the clips on the interior of the hood to installation instructions provided with each keep excess power cord away from moving blower for additional wiring instructions. parts. Follow wiring instructions at the blower as Reinstall the electrical box cover and outlined in the specific installation instruc-
ページ20に含まれる内容の要旨
WOLF PRO WALL VENTILATION HOODS BLOWER ASSEMBLIES Wolf Pro wall ventilation hoods are shipped REMOTE BLOWERS without the blower assembly. Wolf internal, BLOWER-60REM (801640) – 600 CFM in-line and remote blower assemblies are remote blower for low-profile wall hoods available as sales accessories through your (except Models W302210I and W362210I), Wolf dealer. and Models W302418 and W302718. IMPORTANT NOTE: Blower options vary with BLOWER-90REM (801641) – 900 CFM the cooking surface. Use only a