RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION The manufacturer will not be held liable for any damages resulting from in- correct or improper installation. The minimum safety distance between the cooker top and the extractor hood is 650 mm. Check that the mains voltage corresponds to that indicated on the
ページ3に含まれる内容の要旨
CHARACTERISTICS Dimensions
Components Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 9 1 Reducer Flange ø 150-120 mm 10 1 Damper 14.1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4,2
ページ4に含まれる内容の要旨
INSTALLATION Wall drilling and bracket fixing Wall marking: Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. Draw a horizontal line at 650 mm above the hob. Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. Mark the wall at the centres of the hole
ページ5に含まれる内容の要旨
Mounting the hood body Before attaching the hood body, tighten the two screws Vr lo- cated on the hood body mounting points. Hook the hood body onto the screws 12a. Fully tighten support screws 12a. Adjust screws Vr to level the hood body. Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120mm, the choice of which is left to the installer. To
ページ6に含まれる内容の要旨
ELECTRICAL CONNECTION Connect the hood to the mains through a two-pole switch hav- ing a contact gap of at least 3 mm. Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. Chimney assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7.2.1, making sure that they are well seated.
ページ7に含まれる内容の要旨
USE Control board Key Function Display A Switches the motor on and off at the latest Indicates the selected speed selected speed B Decreases the suction speed. - C Increases the suction speed. - D By pressing this key it is possible to start the HI and the remaining time appear alternately. intensive speed from any previously selected The spot down at the right side flashes once a speed. This speed has been timed at 10 min- second. utes. After that time the system
ページ8に含まれる内容の要旨
MAINTENANCE Metal grease filters Filters can be washed in the dish machine. They need to be washed when FF-sign appears on the display or in any case every 2 months, or even more frequently in case of particularly inten- sive use of the hood. Alarm reset Press the G-key for at least 2 seconds. Cleaning Remove the filters one at a time holding them up with one hand and pulling the handle downwards with the other hand at the same time. Wash the filters. Pay attention not to bend
ページ9に含まれる内容の要旨
Charcoal filter (recycling version) This filter cannot be washed or regenerated. It has to be replaced when the EF appears on the display or at least once every 4 months. Activation of the alarm signal In the recycling version hoods the filter saturation alarm has to be activated during the in- stallation or later. Switch off the hood and the lights. Press the E-key for about 5 seconds until the LED on the display start to move. Press the B-key within 5 seconds until a confirmati