ページ1に含まれる内容の要旨
EN
KCVR9NE specific Instruction Manual
KCVR9NE
ページ2に含まれる内容の要旨
EN Installation instructions: KCVR9NE
ページ3に含まれる内容の要旨
EN Grease filter extraction instructions. Top removable glass Bottom removable glass 1)Top glass extraction phases: NB: Extract the bottom glass in the same manner. KCVR9NE
ページ4に含まれる内容の要旨
EN 2) Grease filter extraction: To remove the metal grease filter, follow the instructions carried in the General Instruction Booklet. KCVR9NE
ページ5に含まれる内容の要旨
EN Electronic control system instructions for use: Technical Features: • Power supply from mains: 230 VAC – 50/60 Hz • Power consumption in standby: 20 mA • Max. load applicable to LIGHTS connection: 150 W • Max. load applicable to MOTOR connection: 400 W (capacitor motors only) • Microprocessor-controlled electronic control system. • Loads managed by solid-state components, opto-isolated from the mains. • Hardware and software EMC filtering. • Connection to electronic control boar
ページ6に含まれる内容の要旨
EN Operating Features Keypad with 10 touch buttons + 2 digit display + IR-RX Buttons from left to right: • MOTOR ON/OFF Starts and stops the blower motor. The display shows the current speed setting. • SPEED – Reduces motor speed: V4 → V3 → V2 → V1 • SPEED + Increases motor speed: V1 → V2 → V3 → V4 • BOOST-SPEED MODE Enables BOOST-SPEED mode from any motor speed or when motor is off. To disable BOOST-SPEED, press the button again and stop the motor. BOOST-SPEED mode is s
ページ7に含まれる内容の要旨
EN • RESET FILTRI: Resets the filter saturation alarm if pressed for 2s when all the loads (motor+lights) are off. • If there is a metal Filter sat. alarm, FF appears on the display, after 100 h of operation. • If there is a CA filter alarm, EF appears on the display after 200h of operation. • REDUCE LIGHT INTENSITY • LIGHTS ON/OFF Turns the hood lights on and off at maximum intensity. The increase/reduce buttons adjust the lights’ intensity by 4 steps, excluding max. intensity.
ページ8に含まれる内容の要旨
EN FILTER SATURATION ALARM; RESETTING THE HOOD WORKING HOURS COUNTER • After the hood has been running for 100 hours the display shows FF, meaning that the GREASE FILTERS should be cleaned; • After 200 hours of running, the display shows EF, meaning that the GREASE FILTERS should be cleaned and the A.C. filter cartridges replaced (the latter warning appears only if the A.C. FILTER alarm function has been enabled). NOTE: The warnings appear on the display only when the blower motor i