ページ1に含まれる内容の要旨
ENGLISH ESPAÑOL
LG
Window-Type Air Conditioner
LG
OWNER'S MANUAL
MODELS: L8004R, L1004R, CL8000ER
IMPORTANT
Please read through this manual. It contains valuable
information about your air conditioner. This manual may help
save time and money by explaining proper air conditioner
maintenance and preventing improper use.
PRECAUTIONS
Pay close attention to precautions in order to prevent
potential hazards and damage from misuse or improper
installation. LG is not responsible for any damages caused
ページ2に含まれる内容の要旨
Window-Type Air Conditioner Owner’s Manual TABLE OF CONTENTS Safety Precautions..........................3 FOR YOUR RECORDS Write the model and serial numbers here: Before Operation.............................7 Model # Serial # You can find the numbers on a label on the side of the Introduction ....................................8 product. Symbols Used in this Manual ........8 Dealer's Name Features ........................................8 Date Purchased Staple your receipt to this page in
ページ3に含まれる内容の要旨
ENGLISH Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications. Because of the weight of the product, it is recommended that you have a helper to assist in the installation. This symbol indicates the possibility of death or serious injury. WARNING This symbol indi
ページ4に含まれる内容の要旨
Safety Precautions Operation Plug in the power plug Do not operate or stop the Do not damage or use an properly. unit by inserting or pulling unspecified power cord. out the power plug. • Otherwise, it will cause • It will cause electric shock or • It will cause electric shock or electric shock or fire. fire. fire. ON ON Do not modify power cord Use the air conditioner on a Always plug into a length. single outlet circuit. (See page 7.) grounded outlet. Do not share the outlet with other ap
ページ5に含まれる内容の要旨
ENGLISH Safety Precautions Close all doors, windows and other outside Ventilate before operating air conditioner openings to the room. when gas goes out. • The air conditioner must be operated in a • It may cause explosion, fire, and burn. enclosed area to be most effective. If water enters the product, turn off the the Do not clean the air conditioner with water. power switch of the main body of appliance. Contact service center after taking the power- plug out from the socket. • It will caus
ページ6に含まれる内容の要旨
Safety Precautions Operation Be cautious not to touch the Hold the plug by the head Unplug the air conditioner if sharp edges when when taking it out. it will not be used for a long installing. period. • It may cause injury. • It may cause electric shock • It will waste power and damage. consumption in vain and it Sharp may cause accident. edges Unplug the air conditioner Do not put a pet or house Do not use this appliance before cleaning it. plant where it will be for special purpos
ページ7に含まれる内容の要旨
ENGLISH Before Operation Before Operation Preparing for Operation 1. Plug in the power cord properly. 2. Use a dedicated circuit. Overloading the line could create a fire hazard. 3. Do not use an extension cord. See page 10 for more details. 4. Do not start/stop operation by plugging/unplugging the power cord. 5. If the power cord is damaged and requires replacement, have an Authorized Servicer install an exact replacement part. Usage 1. Being exposed to direct airflow for an extended period of
ページ8に含まれる内容の要旨
Introduction Introduction Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. Tip! This symbol indicates special notes. Features WARNING: This appliance should be installed in accordance with the National Electric Code. Upper Guide Horizontal Air Deflector (Horizontal Louver) Vertical Air Deflector (Vertical Louver) Cabinet Air Discharge Front Grille Air Intake Air Filter (Inlet Grill
ページ9に含まれる内容の要旨
ENGLISH Electrical Safety Electrical Safety WARNING: This appliance must be properly grounded. The power cord of this appliance is equipped with a three-prong grounding plug. To minimize the risk of electric shock, use the plug with a standard three-slot grounding wall power outlet. If the power outlet does not include a grounding slot, have a qualified electrician replace the outlet before you use the room air conditioner. WARNING: Changing the outlet without making the appropriate wiring cha
ページ10に含まれる内容の要旨
Electrical Safety Temporary Use of an Adapter We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection. To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cor
ページ11に含まれる内容の要旨
ENGLISH Installation Installation Type A: 11 EA Type B: 5 EA Type C: 1 EA Type D: 3 EA (Short Screw) (Wood Screw) (Drain Joint Pipe) (L Bracket) Type E: 1 EA Type F: 1 EA Type G: 2 EA Type H: 1 EA (Seal Strip) (Sash Seal) (Guide Panel) (Support Bracket) (Not adhesive backed) (Adhesive backed) Have the following tools available for installation: * Screwdriver (Slotted and Phillips) * Ruler * Knife * Hammer * Pencil * Level Window Requirements Size This room air conditioner is designed for insta
ページ12に含まれる内容の要旨
Installation Clearance Proper clearance enhances the cooling efficiency of the unit and prevents heat radiation of the condenser. 1. If a storm window presents interference, fasten a 2" wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. 3 2. See Figure. B. The top of the wood strip should be approximately /4"
ページ13に含まれる内容の要旨
ENGLISH Center Line Room Side Installation Preparation of Chassis 1. Insert the guide panels into the guides of the air conditioner. Fasten the Type A curtains to the unit with screws (Type A). Tip! : Use a long screwdriver and installing the screws will be easier. Type A 2. Cut the adhesive-backed seal strip (Type E) to the window width. Seal Strip Remove the backing from the seal (Type E) strip and attach the seal strip to the underside of the bottom window. 3. Locating unit in window Open
ページ14に含まれる内容の要旨
Installation Unit Installation Caution: During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from window. 1. Install the air conditioner in the window 1-1. Carefully lift the air conditioner and slide it into the open window. Make C ool F E nergy F F F 1 2 3 M H L O IE G W D H S aver F an Dry T imer T E MP sure the bottom guide of the air conditioner drops into the notc
ページ15に含まれる内容の要旨
ENGLISH Installation 3-4. Fasten the support bracket (Type H) using a screw removed from the air conditioner cabinet. Attach the Type B support bracket (Type H) to the inner window sill with a screw (Type B). Support Bracket (Type H) 4. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. Owner’s Manual 15
ページ16に含まれる内容の要旨
Operating Instructions Remote Control Operations The controls look like this: Controls Cool F F1 LOW F2 MED Energy F3 HIGH 6 Saver Fan TEMP 5 Dry Timer 4 3 2 1 1 POWER Operation starts when this button is pressed and stops when you press the button again. 2 FAN SPEED SELECTOR For increased power while cooling, select a higher fan speed. 3 steps: High Low Med 3 ON/OFF TIMER The timer can be set to start and stop the unit in hourly increments (up to 12 hours). 4 OPERATION MODE SELECTOR Selec
ページ17に含まれる内容の要旨
ENGLISH Operating Instructions Remote Controller CAUTION: The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Controller and the air conditioner. Power Operation starts when this button is pressed and stops when you press the button again. Temperature Control Power The thermostat monitors room temperature to maintain the desired temperature. The thermostat can be set between 60 F~86
ページ18に含まれる内容の要旨
Operating Instructions Additional Features Air Direction Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the cooling efficiency of the air conditioner. Adjusting Horizontal Air Flow Direction Adjusting the vertical louvers left and right will change horizontal airflow. Adjusting horizontal air flow Adjusting Vertical Air Flow Direction Adjusting the horizontal vane up and down will change vertical airflow. The vane can be adjust
ページ19に含まれる内容の要旨
ENGLISH Operating Instructions Additional Features Drain Pipe In humid weather, excess water may cause the Base Pan to overflow. To drain the water, remove the Drain Cap and secure the Drain Pipe to the rear hole of the Base Pan. Drain Pipe Drain Cap Press the drain pipe into the hole by pushing down and away from the fins to avoid injury. This air conditioner is equipped with a slinger fan. (See drawing, below.) The fan has an outer ring that runs in the water that collects in the base p
ページ20に含まれる内容の要旨
Maintenance and Service Maintenance and Service Air Filter Check the air filter at least twice a month to see if cleaning is necessary. Trapped particles in the filter can build up and block the airflow, reducing cooling capacity and causing an accumulation of frost on the evaporator. To clean the air filter: Do not force open or open to far. 1. Pull the inlet grille forward. 2. Remove the air filter from the front grille by pulling the air filter up slightly. 3. Wash the filter using lukewar