ページ1に含まれる内容の要旨
PST - 7700 Series
User’s Manual
Rev. Original
FCC Notes:
This equipment generates, uses, and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions manual, may cause interference to radio communications. It has been tested
and found to comply with limits for a Class A digital device pursuant to subpart J of
Part 15 of FCC Rules, which are designed to provide reasonable protec
ページ2に含まれる内容の要旨
ALERT TO OUR HONORABLE CUSTOMERS: l Please always read thoroughly all the instructions and documents delivered with the product before you do anything about it. Don’t take any premature action before you have a full understanding of the consequences. l This product contains inside a Lithium battery and maybe also a sealed type Lead acid battery if the UPS battery option is ordered. Please always follow local environmental protection laws / regulations for disposal of used batteries and
ページ3に含まれる内容の要旨
BRIEF INTRODUCTION THE USER’S MANUAL The purpose of this manual is to guide the user in the initial installation and general use of the Posiflex PST7700 series of POS terminals. It does not explain any application software that may be supplied with it. We intend to provide our customers with all technology advantages available by evolving the product design to incorporate appropriate changes and improvements. So some detail differences may exist between this manual and the equipment su
ページ4に含まれる内容の要旨
THE STANDARD FEATURES CPU: C3 1.0 GHz; HDD: 20 GB or above; RAM: 128 MB Ethernet Networking: The standard network port works with both 10 Base T and 100 Base T. Programmable Keyboard: In either 112 key matrix or 136 key QWERTY layout with 8 KB memory. Numerical Keypad: The matrix layout keyboard contains a numerical keypad. 6 Position Key Switch: Every PST7700 system is equipped with a 6 position key switch for several purposes. This key switch supports security lock off and multi-pag
ページ5に含まれる内容の要旨
1). PP-2000 series: Friction type paper feed, 2 stations 9 pin dot matrix impact printer. 2). PP-5600 series: Friction type paper feed, 9 pin dot matrix impact printer 3). PP-5700 series: Sprocket type paper feed, 9 pin dot matrix impact printer 4). PP-7000II series: Friction type auto- paper feed, High-speed thermal sensitive line dot printer 5). PP-7000IIUSB series: Friction type auto- paper feed, High-speed thermal sensitive line dot printer with USB interface 6). PP-7700 series:
ページ6に含まれる内容の要旨
Cashier Display Carton When the order is PST7700 or PST7730, the purchased 9” VGA mono CRT monitor will be shipped in a separate box from the main system unit. When the order is PST7705 or PST7735, the package for the 12.1” color TFT LCD is inserted in a side within the system box. Customer Display Carton This is a separate carton within the main carton and contains the customer display (also called a pole display) when an option of customer display is purchased with the PST system. P
ページ7に含まれる内容の要旨
INSTALLATION GUIDES IMPORTANT Please do not connect the power cord or turn on the main unit until you have fully read the installation guides and followed the instructions!!! TECHNICAL ENHANCEMENTS Applicable technical enhancements in PST7700 series include RTC battery replacement, COM port power supply settings, VGA port power supply settings, DRAM upgrades, CD-ROM drive upgrade and adding a half length PCI adapter card. All these technical enhancement operations require purchase of
ページ8に含まれる内容の要旨
The next step is to Monitor Mounting pass the monitor cable through Hook Lugs a square hole at the back edge Mounting of main unit. Open the back Holes door by sliding two back door latches at the bottom of back Bowl door toward the center. The back door is easily removable. Remove the cable cover by pulling the latch on the underside of the cable cover (ref. drawing below). Connect the VGA cable to the VGA connector through this opening then put the cable cover back VGA
ページ9に含まれる内容の要旨
platform of the main unit till it clicks. Screw the pivot back to secure the base of the cashier display on the display platform of the main unit as in drawing below. Remove the cable cover on the display platform (same way as the instructions for CRT model) and connect the VGA connector of the 12.1” TFT LCD through the cable cover opening into the rear room. Reserve some sag in the cable so that the LCD cashier display will be allowed to turn and reinstall the cable cover. CUSTOMER DIS
ページ10に含まれる内容の要旨
without the transparent key caps (these are in the accessories box). Also supplied with the keyboard are 4 die cut self-adhesive A4 label sheets that may be printed by most conventional means with whatever legends are required by the application. Each type of key top (with transparent key cap) listed in the table at end of BRIEF INTRODUCTION can be separately purchased in certain quantities and applied for variety in keyboard layout presentation. The user may use the Key clip key cl
ページ11に含まれる内容の要旨
preferred for a permanent device like a bar code scanner in POS business. To access the internal connection you must remove the keyboard. To do this first unlock the front door lock and then remove the two mounting screws from the underneath of the chassis located just behind the front edge of the terminal. Once these screws have been removed it is possible to lift the front edge of the keyboard housing and then rotate the keyboard “up and back”. This then exposes the keyboard controller
ページ12に含まれる内容の要旨
CASH DRAWER The PST7700 installed with power management kit option is able to control most of the common cash drawers available on the market. However, it is recommended that the Posiflex CR-3100 or CR-3200 or CR-4000 or CR- 4100 or CR-4210 be used since the terminal has been designed to compliment these cash drawers both mechanically and electrically. The PST7700 will directly control the cash drawer using the cash drawer port (CR) both to operate the opening mechanism and to monitor th
ページ13に含まれる内容の要旨
USING THE PST SYSTEM BEFORE POWER ON – A Check List It is very important that you check the following operational points: Ventilation This terminal must NOT be operated in an environment with restricted ventilation. There must be at least 25 mm air clearance around any top or side ventilation holes with a free flow of air around the unit at ALL times for the installation. Operating Environment The equipment must not be operated or stored in extremes of both temperature and humidity/m
ページ14に含まれる内容の要旨
room also provides very good protection as long as the ambient temperature remains below 30°C and the ventilation of the PST system is free. However, should any accident happen and the sulfuric acid from the battery spills on skin or clothing, wash immediately with water. If the acid comes in contact with eyes, rinse eyes with large amount of clean water and see a doctor immediately. A larger external battery may be connected to give an extended operation. Please check your dealer about
ページ15に含まれる内容の要旨
AC power is available when the system is powered off. (b) With a UPS battery fitted together with the power management kit: 1. The standby LED lights steadily to indicate the presence of AC power at system powered off. The system cannot be turned on if the AC power fails. The power LED goes ON and the standby LED goes OFF when the system is powered up. 2. During power failure period at system turned on, the power LED flashes to indicate that the system is running on battery power. 3. T
ページ16に含まれる内容の要旨
choose for “PM Wake Up Events” in “Power Management Setup” and make the “Ring Power Up Control” enabled for Modem Ring Up or select the “Power Up by Alarm” for Alarm Clock Wake Up. Save the configuration and exit the CMOS setup program. The Preset Power On Control will then be ready. For LAN wakeup, an operating caller system connected through LAN to the system is required. It also requires a qualified networking technician to check the LAN chip ID of the system for the caller system to
ページ17に含まれる内容の要旨
LCD MONITOR (for PST7705/PST7735) Mechanical Adjustments The 12.1” LCD color display is integrated on display platform to give the operator the clearest view. The display may be lifted from the horizontal to the upright position and rotated through a total of 90° (left 45° max., right 45° max.). Please do not to attempt to exceed these limits. Display Controls There are some push buttons on side of the LCD panel including power ON/OFF switch and the OSD knob. Please use OSD knob and fi
ページ18に含まれる内容の要旨
There are 4 keys supplied with each keyboard and the lock is so designed that each key may turn the 6 position key switch to correspondent position range. The keys are named: PRG, REG, Z, GT. The available positions for each key type are listed in the table below: ü= accessible û= not accessible PRG REG Z GT ü û û û LP ü ü ü ü LCK L1 ü ü ü ü ü ü ü ü L2 ü û ü ü L3 L4 û û û ü Therefore, if each page is programmed for different level of authority, each key can be distributed fo
ページ19に含まれる内容の要旨
of the slot, or sliding the card upward from the lower side of the slot till it reaches the top end as long as the card is a standard one. A non-standard card recorded without complete degaussing prior to recovery may accept only one direction in card reading. The MSR indicator will light up in green when the MSR is ready to read, blink during reading, and then give a green light if the reading is successful. The MSR indicator will turn to be red if the reading fails due to improper sli
ページ20に含まれる内容の要旨
PRINTER One of the major design features of the PST terminals is the ability to accommodate a very large range of printers. The terminal provides a printer platform where the printer can be mounted (use the Velcro strips in the accessories kit for fixation aid), and also provides a regulated 24 volts DC power line to power the printer. The terminal can accommodate both parallel and serial interfaces. Please consult the printer user manual before assembling and connecting any printers t