ページ1に含まれる内容の要旨
SE-S10
Electronic Cash Register
(SE-S10 small drawer model)
User's Manual
START-UP is QUICK and EASY!
Simple to use!
20 departments and 500 PLUs
Automatic Tax Calculations
Calculator function
CASIO COMPUTER CO., LTD.
EU
6-2, Hon-machi 1-chome
DI
Shibuya-ku, Tokyo 151-8543, Japan
UK
ページ2に含まれる内容の要旨
INTRODUCTION Thank you very much for purchasing this CASIO electronic cash regis- ter. START-UP is QUICK and EASY! Part-1 of this User's Manual can help you make a quick start. Once you have mastered the QUICK START operations, you will un- doubtedly want to expand your use of this machine by studying other sections of Part-2. Original Carton/Package Power Supply If for any reason, this product is to be returned Your cash register is designed to operate to the store where purchased, it must be
ページ3に含まれる内容の要旨
INTRODUCTION Safety precautions • To use this product safely and correctly, read this manual thoroughly and operate as instructed. After reading this guide, keep it close at hand for easy reference. Please keep all informations for future reference. • Always observe the warnings and cautions indicated on the product. About the icons In this guide various icons are used to highlight safe operation of this product and to prevent injury to the operator and other personnel and also to prevent dam
ページ4に含まれる内容の要旨
INTRODUCTION Warning! Use a dry cloth to periodically wipe off any dust built up on the prongs of the plug. Humidity can cause poor insulation and create the danger of electric shock and fi re if dust stays on the prongs. Do not allow the power cord or plug to become damaged, and never try to modify them in any way. Continued use of a damaged power cord can cause deterioration of the insulation, exposure of internal wiring, and short circuit, which creates the danger of electric shock and fi r
ページ5に含まれる内容の要旨
Contents Getting to know your cash register .................................................................... 6 Daily Job Flow ................................................................................................... 8 Part-1 QUICK START OPERATION ........................................................... 9 1. Loading Memory Protection Battery ........................................................... 9 2. Loading Paper Roll ........................................................
ページ6に含まれる内容の要旨
Getting to know your cash register Getting to know your cash register Mode Switch The position of the Mode Switch controls the type of operations you can perform on the cash register. The PROGRAM key (marked PGM) CAL X Z REG can be select any Mode Switch setting, while OPERATOR key (marked OP) can be used to select OFF, REG or CAL only. OFF RF PGM RF OFF REG CAL X Z PGM OP key ● ● ● PGM key ● ● ● ● ● ● ● OFF In this position, the power of the cash register is off. OP PGM REG (Regis
ページ7に含まれる内容の要旨
Getting to know your cash register Keyboard • Department 6 through 20 are specifi ed by pressing the key respectively as follows: j PAPER POST TAX PGM HELP SAVING RECEIPT ~ → j j Department 6 ~ 10 — % # ~ → jj jj Department 11 ~ 15 DATE ERR. DEPT FEED PLU C AC CLK# CORR TIME SHIFT ~ → jjj jjj Department 16 ~ 20 4 5 PAPER RC G Paper saving key PD SAVING 7 8 9 MR 9/14/19 10/15/20 Paper saving key is the key to save printing 3 CHK paper (Journal compressed printing/ No
ページ8に含まれる内容の要旨
Daily Job Flow Daily Job Flow Before Opening The Store 1. Plugged in? 2. Enough Roll Paper? Page-11 3. Date and Time is correct? Page-40 4. Enough small change in the drawer? Page-41 While The Store Is Open 1. Registrations. Page-14 ~ 2. Issuing latest daily sales total if need- ed. (Generating report by Mode Switch to X position.) Page-18 After Closing The Store 1. Issuing Daily Sales Total. (Resetting report by Mode Switch to Z position.) Page-19 2. Picking up money in the drawer. Pag
ページ9に含まれる内容の要旨
Part-1 Part-1 QUICK START OPERATION QUICK START OPERATION Part-1 1. Loading Memory Protection Battery Important You must initialize the Cash register. 1. Remove the printer cover. 2. Open the battery compartment cover. 3. Load 2 new UM-3, or R6P (SUM-3) type batteries into the compartment. Be sure that the plus (+) and minus (–) ends of each battery are facing in the directions indicated by the il- lustrations inside the battery compartment (Figure 1). 4. Replace the memory protection batter
ページ10に含まれる内容の要旨
Part-1 QUICK START OPERATION 3. Setting the Cash Register ! Plug the power cord of the cash register into AC outlet. @ Please choose your language followed by printed message. # When the display shows blinking "0", such as 00-00-00 Enter current date in Day, Month, Year. $ When the display shows blinking "0", such as 00-00 Enter current time in Hour, Minute. % Set the mode switch to REG. ^ Tear off any excess paper. & Replace the printer cover slowly. *Default printer defi nition is receipt pri
ページ11に含まれる内容の要旨
Part-1 Part-1 QUICK START OPERATION 5. To remove receipt paper ! Open the platen arm. Remove the core of the paper. @ 6. To remove journal paper ! Remove the printer cover by $ Remove the take-up reel & Remove the core of the pa- lifting up the back. from the printer and take off per. the left plate of the reel. % Remove the journal paper from the take-up reel. @ l Press the key until ap- * Load new paper following the proximately 20cm of the pa- instructions "1. To load jour- per is fe
ページ12に含まれる内容の要旨
Part-1 QUICK START OPERATION Mode Switch 8. Basic Programming for QUICK START CAL X Z REG OFF RF PGM Procedure Purpose 1. To select the date format and monetary mode (if necessary) You can select the date format and monetary mode after initialization depending on the requirements in your area. Default date format is Day/ Month/ Year and default monetary mode is add 2. C Date Format Selections P3 appears in mode display Select date format Year/ Month/ Day ? and Day/ Month/ Year Z ?ZXX
ページ13に含まれる内容の要旨
Part-1 Part-1 QUICK START OPERATION Procedure Purpose 3. In case of accepting two (the Euro and the local) currencies. 3-1. Press the following keys to defi ne the main currency/print out currency of the subtotal. C P3 appears in mode display XVXX Euro status Z p (1) Main currency = Local, Print out subtotal = Local: ? Euro Status (2) Main currency = Euro, Print out subtotal = Euro : Z (3) Main currency = Local, Print out subtotal = Both: X (4) Main currency = Euro,
ページ14に含まれる内容の要旨
Part-1 QUICK START OPERATION Mode Switch 9. Basic Operation after Basic Programming CAL X Z REG Note: OFF Whenever an error is generated, the input fi gures reset to 0. All printout samples are journal images and the header (date, time and consecutive RF no.) are eliminated from the samples. PGM Printout Operation 08-01-2010 08:55 m 9-1 Open the drawer REG 0001 without a sale — No Sale Symbol NS •••••••••• 08-01-2010 09:00 9-2 Basic operation Z?? REG 0002 Example Unit Price Department
ページ15に含まれる内容の要旨
Part-1 Part-1 QUICK START OPERATION 9-5 Split cash/ Printout Operation charge sales 08-01-2010 09:25 X?? REG 0005 Example C?? Unit Price $2.00 $3.00 $4.00 DEPT01 •2.00 V?? Quantity 1 1 1 DEPT02 •3.00 Dept. 1 2 1 DEPT01 •4.00 Cash B?? p TOTAL •9.00 Amount $5.00 CASH •5.00— Cash Amount Tendered u tendered CHARGE •4.00— Charge Sales Corrections can be made while you are registering the item (before 9-6 Corrections you press a department key), or after it has already been regis- tered
ページ16に含まれる内容の要旨
Part-1 QUICK START OPERATION Mode Switch CAL X Z REG OFF RF PGM Printout Operation 9-6-2 After you pressed a g key cancels the last registered item. department key Example BB? DEPT01 •5.50 1. Entered unit price 550 by Wrong entry ERR CORR -5.50 mistake instead of 505 and DEPT01 •5.05 g pressed a department key. Cancels the last item registered. B?B Correct entry Registered Department 1 2. Entered unit price 220 by C h mistake instead of 230 3 x @2.20 and pressed a depa
ページ17に含まれる内容の要旨
Part-1 Part-1 QUICK START OPERATION Mode Switch 9-7 Registering with CAL X currency exchange Z REG OFF RF PGM Display Operation Example Unit Price £2.00 C h Quantity 3 X?? Dept. 1 1 ; Cash Amount 10.00 Euro tendered '50e Rate 1Euro = £ 0.8 Pressing ] before subtotal converts the Main currency Local (£) subtotal amount into the Euro. Printout of ST Both currencies Z?' ; 1~00e Pressing ; after amount tendered converts the amount into the Euro. *1 p "00 Press p to fi
ページ18に含まれる内容の要旨
Part-1 QUICK START OPERATION 10. Daily Management Report This section tells you the procedures to use to produce reports of the transaction data stored in the cash register's memory. Important Remember that when you issue a reset (Z) report, the data that is reported is cleared from the applicable totalizers. To view data without clearing totalizers, issue a read (X) report. Printout Operation 10-1 Financial Report 08-01-2010 19:10 X 0070 h Mode Switch FLASH X — Read Symbol X CAL Z RE
ページ19に含まれる内容の要旨
Part-1 Part-1 QUICK START OPERATION Printout Operation 10-2-2 Daily Read/Reset Z (Reset) report Report 08-01-2010 19:25— Date/Time Z 0073— Consecutive No. Mode Switch to (Read) p Non-resettable No. of X 0000 DAILY Z 0012— *1 *1 Resets /RESET Symbol DEPT01 QT 48— Dept. Name/ No. of Items •50.10— Amount DEPT02 QT 28 •76.40 DEPT03 QT 17 p Mode Switch to (Reset) Z •85.80 DEPT20 QT 4 •3.00 Mode Switch ------------------------ CAL X GROSS TOTAL QT
ページ20に含まれる内容の要旨
Part-2 CONVENIENT OPERATION Part 2 CONVENIENT OPERATION Mode Switch CAL X Z REG 1. Various Programming OFF 1-1 Unit price for Departments RF PGM Z Example Unit Price $1.00 $2.20 $11.00 P appears in mode display Dept. 1 2 3 Z?? (For Dept. 1) XX? (For Dept. 2) ZZ?? (For Dept .3) • Unit prices within the range of 0.01~9999.99. 1-2 Rate for percent key Example Z Discount Rate 2.5% P appears in mode display X"B : (To end the setting) • The rate within the range of 0.01 to 99.99%. Tax st