ページ1に含まれる内容の要旨
2-659-026-13 (1)
LCD Monitor
Instructions for Use
LMD-1420MD
© 2005 Sony Corporation
ページ2に含まれる内容の要旨
For the customers in Canada Owner’s Record This unit has been certified according to Standard CSA The model and serial numbers are located at the rear. C22.2 NO.601.1. Record these numbers in the spaces provided below. Refer to these numbers whenever you call upon your FOR THE CUSTOMERS IN THE USA Sony dealer regarding this product. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Model No. ____________________ Part 15 of the FCC Ru
ページ3に含まれる内容の要旨
Important safeguards/notices for use in the WARNING on power connection for medical environments medical use Please use the following power supply cord. 1. All the equipment connected to this unit shall be With connectors (plug or female) and cord types other certified according to Standard IEC60601-1, than those indicated in this table, use the power supply IEC60950-1, IEC60065 or other IEC/ISO Standards cord that is approved for use in your area. applicable to the equipment. 2. When thi
ページ4に含まれる内容の要旨
Table of Contents Precaution ..............................................................5 On Safety ............................................................ 5 On Installation .................................................... 5 Handling the LCD Screen .................................. 5 About the Fluorescent Tube ............................... 5 On Cleaning ....................................................... 5 On Repacking ..................................................... 6 On
ページ5に含まれる内容の要旨
� If a still picture is displayed for a long time, a residual image may appear. The residual image will eventually Precaution disappear. � The screen and the cabinet become warm during operation. This is not a malfunction. On Safety � Operate the unit only with a power source as specified About the Fluorescent Tube in the “Specifications” section. � A nameplate indicating operating voltage, power A specially designed fluorescent tube is installed as the consumption, etc., is located on t
ページ6に含まれる内容の要旨
On Repacking Features Do not throw away the carton and packing materials. They make an ideal container which to transport the The LMD-1420MD is a 14-type LCD monitor that unit. conforms to medical safety standards. This unit is suitable for endoscopy or use as a sub-monitor. On Mounting on a Rack Compliance with medical safety standards in America, Canada and Europe Leave 1U space empty above and below the monitor to UL60601-1 for America, CSA C22.2 No.601.1 for ensure adequate air circ
ページ7に含まれる内容の要旨
External sync input When the EXT SYNC button is in the on position, the unit can be operated on the sync signal supplied from an external sync generator. Automatic termination (connector with mark only) The input connector is terminated internally at 75 ohms when nothing has been connected to the output connector. If a cable is connected to the output connector, the internal terminal is automatically released and the signals input to the input connector are output to the output connect
ページ8に含まれる内容の要旨
Location and Function of Parts and Controls Front Panel 1 MENU VOLUME POWER RGB/ EXT BLUE LINE A LINE B COMPONENT SDI SYNC ONLY SCAN ASPECT RESET ENTER qdqsqa09876 5 4 3 2 MENU VOLUME POWER RGB/ EXT BLUE LINE A LINE B COMPONENT SDI SYNC ONLY SCAN ASPECT RESET ENTER qf a Tally lamp RESET button The lamp lights in green when this unit is controlled Resets the value of an item back to the previous from the PARALELL REMOTE terminal on the rear value. This button functions when the menu item is pa
ページ9に含まれる内容の要旨
j SDI button m LINE A button Press to monitor the signal from the OPTION IN Press to monitor the signal through the IN (input) connector. connector of the LINE A connectors. k RGB/COMPONENT button n Speakers Press to monitor the signal through the IN (input) The audio signal which is selected by the input select connector of the RGB/COMPONENT connectors. button on the front panel is output. l LINE B button Press to monitor the signal through the IN (input) connector of the LINE B connectors.
ページ10に含まれる内容の要旨
Rear Panel 9 8 7 6 5 4 321 LINE A PARALLEL REMOTE RGB/COMPONENT OPTION IN OUT IN OUT AUDIO IN G/Y OPTION IN LINE B IN OUT IN OUT IN OUT IN EXT OUT VIDEO VIDEO B/PB SYNC LINE A PARALLEL REMOTE RGB/COMPONENT OPTION IN OUT IN OUT AUDIO IN G/Y OPTION IN AC IN IN OUT IN LINE B OUT IN OUT IN EXT OUT VIDEO VIDEO B/PB SYNC IN OUT IN OUT IN OUT IN OUT AC IN AUDIO AUDIO AUDIO R/PR IN OUT IN OUT IN OUT IN OUT AUDIO AUDIO R/PR AUDIO a OPTION IN connector (D-sub 9-pin, female) d RGB/COMPONENT connectors When
ページ11に含まれる内容の要旨
MENU VOLUME POWER RGB/ EXT BLUE LINE A LINE B COMPONENT SDI SYNC ONLY SCAN ASPECT RESET ENTER VIDEO IN/OUT (BNC) These are the input/output connectors for a Installing to the Rack composite video signal. Connect them to the composite video input/output connectors on 1 Remove the screws (4) to remove the stand. equipment such as a VCR, video camera, or another monitor. AUDIO IN/OUT (RCA pin) These are the input/output jacks for an audio signal. Connect them to the audio input/output jacks on
ページ12に含まれる内容の要旨
LINE A IN OUT IN OUT VIDEO AC IN INOUT AUDIO LINE A IN OUT IN OUT VIDEO AC IN IN OUT AUDIO Connecting the AC Attaching the Input Power Cord Adaptor Connect the supplied AC power cord as illustrated. Before attaching the input adaptor, disconnect the power cord. 1 Plug the AC power cord into the AC IN socket on the rear panel. Then, attach the AC plug holder (supplied) to the AC power cord. AC IN socket AC plug holder (Supplied) AC power cord Note Do not install the equipment other than BKM
ページ13に含まれる内容の要旨
Selecting the Default Settings When you turn on the unit for the first time after purchasing it, select the area where you intend to use this unit from among the options. The default setting values for each area MENU VOLUME POWER RGB/ EXT BLUE LINE A LINE B COMPONENT SDI SYNC ONLY SCAN ASPECT RESET ENTER 3 MENU VOLUME POWER RESET ENTER 1 5 2~3 1 4 2 3 3 1 Press the POWER switch. The power is turned on and the SELECT SETTING screen appears. COLOR COMP NTSC 1North America TEMP LEVEL SETUP S E
ページ14に含まれる内容の要旨
4 If ASIA EXCEPT JAPAN is selected: Customers who will use this unit in the shaded Selecting the Menu areas shown in the map below should select NTSC AREA. Language Other customers should select PAL AREA. You can select one of seven languages (English, French, German, Spanish, Italian, Japanese, Chinese) for displaying the menu and other on-screen displays. The current settings are displayed in place of the x marks on the illustrations of the menu screen. MENU VOLUME POWER RGB/ EXT BLUE L
ページ15に含まれる内容の要旨
3 Press the M or m button to select the USER CONFIG 1/2 (User Configuration 1/2) menu, then Using the Menu press the , or ENTER button. The setting items (icons) in the selected menu are The unit is equipped with an on-screen menu for making displayed in yellow. various adjustments and settings such as picture control, input setting, set setting change, etc. You can also USER CONFIG (1/2) Rr change the menu language displayed in the on-screen · RGB/COMP SEL xxxx menu. · COMP LEVEL x
ページ16に含まれる内容の要旨
3 Press the M or m button to select the item, then press the , or ENTER button. Adjustment Using the The item to be changed is displayed in yellow. Menus Note If the menu consists of multiple pages, press M or m to go to the desired menu page. Items The screen menu of this monitor consists of the 4 Make the setting or adjustment on an item. following items. When changing the adjustment level: To increase the number, press the M button. STATUS (the items indicate the To decrease the number,
ページ17に含まれる内容の要旨
KEY INHIBIT Submenu Setting KEY INHIBIT COLOR TEMP Select the color temperature from among HIGH, LOW, LOW2 and USER setting. � HIGH (D93 or equivalent) Adjusting and Changing the � LOW (D65 or equivalent) Settings � LOW2 (D56 or equivalent) �USER MANUAL ADJ If you set the COLOR TEMP to STATUS menu USER setting, the item displayed is The STATUS menu is used to display the current status changed from blue to white, which means you can adjust the color of the unit. The following items are d
ページ18に含まれる内容の要旨
USER CONFIG menu Submenu Setting You can select a language, etc. SCAN Enlarge a 4:3 aspect ratio picture to Items that cannot be adjusted depending on the input a 16:9 aspect ratio picture. Select from “OFF” and “ZOOM” signal are displayed in blue. mode. PIC DELAY MIN Selects to set the delay by the USER CONFIG (1/2) Rr x RGB/COMP SEL xxxx picture processing to the minimum · COMP LEVEL xxxxx level when the signal is input. · NTSC SETUP x � OFF: Mode for giving · GAMMA x · FORMAT
ページ19に含まれる内容の要旨
REMOTE PARALLEL menu Select the PARALLEL REMOTE connector pins for Troubleshooting which you want to change the function. You can assign various functions to 1 to 4 pins and 6 to This section may help you isolate the cause of a problem 8 pins. The following lists the functions you can assign and as a result, eliminate the need to contact technical to the pins. support. � The display is colored in green or purple t By pressing RGB/COMPONENT button, select the REMOTE PARALLEL correct input w
ページ20に含まれる内容の要旨
Output LINE A output connectors Specifications Y/C output 4-pin mini-DIN (1), Loop-through, with 75 ohms automatic terminal function Picture performance VIDEO output LCD panel a-Si TFT Active Matrix BNC type (1), Loop-through, with 75 Picture size 14 type ohms automatic terminal function 283 × 212 × 354 mm (W/H/ 1 3 AUDIO output Diagonal) (11 /4 × 8 /8 ×14 inches) RCA pin (1), Loop-through Resolution 640 × 480 dots (VGA) LINE B output connectors Viewing angle 85°/85°/85°/85° (typical) VIDE