ページ1に含まれる内容の要旨
more than 10cm
more than 10cm
more than 10cm
more than 15cm
Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Necessary Tools for Installation
1.Driver 5.Torque wrench(17mm,22mm,26mm) 9.Nipper 12.Reamer
2.Hacksaw 6.Pipe cutter 10.Gas leakage detector or
3.Hole core drill 7.Flaring tool soap-and-water solution
4.Spanner(17,19 and 26mm) 8.Knife 11.Measuring tape
Drawing for the install
ページ2に含まれる内容の要旨
Floor fixing dimensions of the outdoor unit (Unit:mm) HSU-09H03/K(F) HSU-12H03/K(F) HSU-12C03/K(F) Selection of pipe To this unit, both liquid and gas pipes shall be insulated For 09k For 12k as they become Iow temperature in operation. Liquid pipe ( ) 6.35mm(1/4") 6.35mm(1/4") Use optional parts for piping set or pipes covered with Gas pipe ( ) 9.52mm(3/8") 12.7mm(1/2") equivalent insulation material. Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the m
ページ3に含まれる内容の要旨
Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor
ページ4に含まれる内容の要旨
Outdoor unit Outdoor unit 1.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Fastening torque Pipe Diameter ( ) Spanner Liquid side 6.35mm(1/4") 18N.m Torque wrench Gas side 9.52mm(3/8") 40