ページ1に含まれる内容の要旨
CEILING CONCEALED TYPE AIR CONDITIONER INDOOR UNIT
Household MRV
Ceiling Concealed Type Room Air Conditioner
AE092FCAJA AE182FCBJA
AE182FCAJA AE182FCBJA
5
8
Health and power failure compensation function
14
15-16
Fault occurs 17
18
Installation precautions 19-20
21-33
34
0010572352
ページ2に含まれる内容の要旨
1
ページ3に含まれる内容の要旨
AE092FCAJA,AE182FCAJA 21*/18* AE092FCBJA,AE182FCBJA 21*/15.5* 2
ページ4に含まれる内容の要旨
* R407C:AE092FCBJA AE182FCBJA R22: AE092FCAJA AE182FCAJA Buttons of the remote controller. Operation Buttons of the wire controller. 5 6 4 TIMP 4 ON 7 2 OFF SWING FAN SPEED 8 10 MODE SLEEP 9 1 9 HEALTH NEW FAN 10 11 3 CLOCK SET 12 7 5 TIMER 1.MODE 6.TIMER 6 Used to select AUTO Used to select RUN, COOL, DRY, TIMER ON, 8 ** HEAT and FAN TIMER OFF, 13 12 operation. TIMER ON/OFF. 7.SET 2.FAN SPEED Used to confirm Timer Used to select fan and Clock settings. speed: LO, MED, HI, AUTO 8.TIME Used
ページ5に含まれる内容の要旨
* * Operation Display of the wire controller and remote controller. 4 1 5 2 6 6 3 12 7 4 13 5 8 10 13 TIMP 9 ON 7 OFF SWING FAN SPEED 8 MODE SLEEP 11 9 HEALTH NEW FAN 12 10 CLOCK SET TIMER 8.TIMER ON 1.AUTO 9.TIMER OFF 2.COOL ** 10.CLOCK 3.DRY 11.OPERATING LAMP 4.HEAT 12.TEMP. 5.FAN OPERATION 13.LOCK. 6.SLEEP 7.FNA SPEED Note:The above information is the explanation of the displayed information therefore varies with those displayed in actual operation. Clock set When unit is started for the firs
ページ6に含まれる内容の要旨
* Make sure that the remote controller is used within 7 meters from receiver window of the wire controller and there are no obstructions in between. * The remote controller or wire controller should be handled with care. * When operating the remote controller in an area where electronically controlled lights are installed or wireless handsets are used, move closer to the indoor unit as the function of the remote controller might be affected by signals from this equipment. Battery loading Batter
ページ7に含まれる内容の要旨
Warning for installation Important Points of Safety The following four important points of safety and suggestions should be paid great attention: ! Warning: Misuse may cause fatal result such as death or serious injury etc. ! Attention: Misuse may cause human injury or damage of machine, in some case fatal results. : Content marked with this ìforbiddenî sign should be absolutely forbid- den, otherwise may cause damage of machine and human
ページ8に含まれる内容の要旨
Warning for use Warning for move and repair Attention points for installation Important Points of Safety ! Warning l Avoid your body being blown l If something abnormal (e.g.: burnt directly by cold wind for long smell etc.) occurs, stop running the period, otherwise your health machine, shut down the manual may be affected. power switch and contact after service. Continuous operation in l Donít extend your fingers or disorder may cause fire hazar
ページ9に含まれる内容の要旨
Attention points for use Important Points of Safety Attention ! * Ensure ventilation of the room* DONíT lay any burning facilities if the machine is used with in place where winds produced by burning facilities. Deficient the machine can reach. Incomplete ventilation can cause oxygen combustion of burning facility may shortage. be caused otherwise. * Check whether installation bench of the machine is * DONíT clean the machine with
ページ10に含まれる内容の要旨
* Operating instructions The air conditioner has the function of POWER FAILURE RESUME. MODE FAN TEMP HEALTH3 2 (3) Fan CLOCK SET TIMP ON TIMER SLEEP Press wire controller FAN button. For OFF SWING FAN ROOM each press,fan speed changes as FILTER RESET RESET MODE SLEEP AM follows: 4 ON/OFF 1 LOW MID HIGH ** Fan operation Press remote controller FAN button. For each press,fan speed changes as Enjoy yourself by just a follows: gentle press. (1) Unit start Press ON/OFF button, unit starts. LOW MID
ページ11に含まれる内容の要旨
* Operating instructions AUTO RUN, COOL,HEAT and DRY operation Recommendations Use COOL in summer. Use HEAT in winter. Use DRY in spring,autumn and in damp climate. TIMP ON MODE FAN OFF SWING 5 TEMP HEALTH 2 4 MODE SLEEP CLOCK SET 3 SET TIMER SLEEP FILTER RESET RESET AM 5 ** ON/OFF 1 (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display (Not Timer setting). Power indicator lights up. Press FAN button. For each press, fan speed changes as follows: AUTO Wir
ページ12に含まれる内容の要旨
* Operating instructions MODE FAN TEMP HEALTH CLOCK SET TIMP 2 SET TIMER SLEEP ON 4 OFF SWING 1 FILTER RESET 3RESET AM AM MODE SLEEP ON/OFF 1 2 4 3 ** TIMER operation Set Clock correctly before starting Timer operation. You can let unit start or stop automatically at following time: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (3)Timer setting (1)After unit start, select your desired operation mode. Press TIME butto
ページ13に含まれる内容の要旨
* Operating instructions MODE FAN TEMP HEALTH 3 CLOCK SET TIMP 2 SET TIMER SLEEP ON 6 OFF SWING 1 FILTER RESET RESET 5 4 MODE SLEEP AM PM 3 ON/OFF 2 1 6 4 5 ** TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator lights up. (2) Press TIMER button to change TIMER (4) Time confirming for TIMER ON mode After time setting, press TIMER button to confirm. Every time the button is pressed, display changes as follows: "ON" stops bl
ページ14に含まれる内容の要旨
* Operating instructions Comfortable Sleep At night, before going to bed you MODE FAN can press down the SLEEP button TEMP HEALTH on the controller and the air- CLOCK SET SET conditioner will run by the TIMER SLEEP comfortable sleeping mode to FILTER RESET RESET AM AM make you sleep more comfortable. ON/OFF In cooling, dehumidifying mode One hour after sleeping operation start, the temp. is 1* higher than the setting one. After another hour the temp. rises 1* and then run continuously for anothe
ページ15に含まれる内容の要旨
* Operating instructions 1.How to use the health function (only for units with this function) After set the right function mode, press health button, MODE FAN remote controller or wire controller displays ì î, oxygen pump or negative ion generator starts up to apply TEMP HEALTH oxygen or negative ion to indoor unit. Press the button CLOCK SET again,the sign ì î disappeared and negative ion generator SET TIMER SLEEP stops working. After all health function of the indoor unit
ページ16に含まれる内容の要旨
Troubleshooting The following cases are not troubles. Water flow sound is heard. During operation, the air conditioner may sometimes exhibit a sound of "clatter" or "Hua-Hua" "rumble". This is the common sound of refrigerant flow but not a trouble. This is caused by the thermal expansion A sound of "Pi-Pa" is generated. or cold shrinkage of plastics. Sometimes there are smells in the air flow Smells are given off. from the indoor unit. This is caused by the smell of cigarettes or paint coatings
ページ17に含まれる内容の要旨
Troubleshooting During DRY operation, there is no air sent out or fan speed cant be changed. In HEAT mode, the outdoor unit This occurs during removal of the frost generates water or steam. (in defrosting operation) on the radiator of outdoor unit. Defrost operation In HEAT mode, the indoor fan still After the unit stops, the indoor fan will keeps running even the unit operation continue to run for a while to eliminate stops. residual heat. Before asking for after-service to an authorized servic
ページ18に含まれる内容の要旨
When fault occurs Poor cooling or heating Is the operation controller Is there any door or window Are there any obstructs adjusted as required? left open? before the air inlet or outlet? Poor cooling Is there any other heat Is there any direct sunlight Are there too many people source in the room? into the room? in the room? When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed, stop the operation of the a
ページ19に含まれる内容の要旨
Notice to users Notice to users l To ensure proper operation of the system, the user shall follow this instruction manual to install the unit. l When handling the air conditioner, please be care not to scratch the case surface. l This instruction manual describes the installation method aided with the installation tools specified by manufacturer . l The maximum length of connection pipe is 50 m, and the maximum difference between levels of indoor unit and outdoor unit shall be
ページ20に含まれる内容の要旨
Installation precautions Before installing, do read this "Safety precautions" carefully to guarantee the proper installation. ! ! The below attentive matters are divided into" " and " two parts. When the Warning Note" wrong installation occur, it is very possible death and severe injury and other serious accidents will ! ! happen. For those items are listed in part. But even the items listed in " Note" " Warning" part can also cause serious accidents. Above all, both the two parts