Notices and Trademarks Copyright 2008 by Honeywell Revision 5 January 2009 WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties
ページ3に含まれる内容の要旨
About This Document Abstract This document provides descriptions and procedures for the Installation, Configuration, Operation, and Troubleshooting of your UDA2182 Universal Dual Analyzer. Contacts World Wide Web The following lists Honeywell’s World Wide Web sites that will be of interest to our customers. Honeywell Organization WWW Address (URL) Corporate http://www.honeywell.com Honeywell Field Solutions http://www.honeywell.com/ps Technical tips http://content.honeywell.com/ipc
ページ4に含まれる内容の要旨
Symbol Definitions The following table lists those symbols used in this document to denote certain conditions. Symbol Definition This CAUTION symbol on the equipment refers you to the Product Manual for additional information. This symbol appears next to required information in the manual. WARNING PERSONAL INJURY: Risk of electrical shock. This symbol warns you of a potential shock hazard where HAZARDOUS LIVE voltages greater than 30 Vrms, 42.4 Vpeak, or 60 VDC may be
ページ5に含まれる内容の要旨
Contents 1 INTRODUCTION ...................................................................................................1 1.1 Overview.........................................................................................................................................1 1.2 Features...........................................................................................................................................3 2 SPECIFICATIONS.................................................
ページ6に含まれる内容の要旨
5.7.12 Manual Starting/Stopping the Auto Cycle .....................................................................31 5.7.13 Auto Cycle Fail ..............................................................................................................32 5.7.14 Conditional Sequencer Steps..........................................................................................32 5.8 Pharma Display...............................................................................................
ページ7に含まれる内容の要旨
6.16 Variables Configuration ..........................................................................................................105 6.17 Communication Configuration................................................................................................106 6.18 Maintenance Configuration.....................................................................................................108 7 INPUTS AND OUTPUTS WIRING..............................................................
ページ8に含まれる内容の要旨
9 OUTPUTS CALIBRATION ................................................................................178 9.1 Overview.....................................................................................................................................178 9.2 Output Calibration ......................................................................................................................179 10 TEMPERATURE INPUT CALIBRATION ..........................................................185
ページ9に含まれる内容の要旨
15.13 Appendix L – Leak Detection in PPB Applications ............................................................226 15.14 Appendix M – Procedure for Low Level ppb Dissolved Oxygen Testing ..........................227 15.15 Appendix N – Sample Tap Electrode Mounting Recommendations...................................229 15.16 Appendix O – Auto Clean and Auto Cal Examples ............................................................231 15.17 Appendix P – AutoClean and AutoCal Theory and Pip
ページ10に含まれる内容の要旨
Tables Table 3-1 Procedure for Unpacking and Preparing the UDA2182 ______________________________ 10 Table 3-2 Panel Mounting Procedure ____________________________________________________ 11 Table 4-1 Procedure for installing AC Power Wiring________________________________________ 17 Table 5-1 Function of Keys____________________________________________________________ 22 Table 5-2 Display Details Functions _____________________________________________________ 24 Table 5-3 Changing PID
ページ11に含まれる内容の要旨
Table 11-1 Cal History items _________________________________________________________ 189 Table 12-1 Status Messages __________________________________________________________ 192 Table 12-2 Probe Calibration Diagnostics________________________________________________ 193 Table 12-3 Auto Cycle Fail Messages___________________________________________________ 194 Table 12-4 Pharma Fail Messages______________________________________________________ 195 Table 14-1 Part Numbers_______________
ページ12に含まれる内容の要旨
Figure 8-2 Resetting ORP Offset ______________________________________________________ 156 Figure 8-3 Resetting Calibration Trim __________________________________________________ 162 Figure 8-4 Resetting pH Offset ________________________________________________________ 165 Figure 8-5 Display of Probe Bias Test Done in Air ________________________________________ 173 Figure 8-6 Resetting Pressure Offset or Bias Volts_________________________________________ 177 Figure 9-1 Resetting Outpu
ページ13に含まれる内容の要旨
Introduction 1 Introduction 1.1 Overview Multi-function instrument The UDA2182 Universal Dual Analyzer is the next level of dual channel analyzers providing unprecedented versatility and flexibility. The UDA2182 can accept single or dual inputs from Honeywell Direct pH, pH from preamp, ORP (Oxidation Reduction Potential), Contacting Conductivity and Dissolved Oxygen sensors. Measurements for Dual channel units can be arranged in any combination of measurement. User interface “Proce
ページ14に含まれる内容の要旨
Introduction Outputs Two standard Analog outputs 0 –20 or 4–20 mAdc, 750 ohms maximum, isolated from inputs, ground, and each other, and independently assignable to any parameters and ranges Proportional to user-set output range(s) of selected parameter(s). One optional Analog output 0 –20 or 4–20 mAdc, 750 ohms maximum, isolated from inputs, ground, and each other, and independently assignable to any parameters and ranges. Relays Two 4A SPDT alarm/control relays are standard; with an
ページ15に含まれる内容の要旨
Introduction 1.2 Features Standard and solution temperature compensation Measured pH temperature is compensated in one of two ways. Electrode temperature sensitivity is automatically compensated to display the correct pH value at temperature. In addition, displayed pH can be optionally normalized to a solution temperature of 25°C as determined by the current Solution Temperature Coefficient, which is expressed in units of pH/°C with precision to the hundredths decimal place. The param
ページ16に含まれる内容の要旨
Introduction Password protection Keyboard security protects configuration and calibration data. A password (up to four digits) can be configured. If the security feature is enabled, the password will be required to access configuration and calibration software functions. Auto Clean/Auto Cal Built-in real time clock is used to set-up versatile cycles that can be used to initiate automatic sensor cleaning and then calibration. Diagnostic/Failsafe Outputs Continuous diagnostic routines
ページ17に含まれる内容の要旨
Specifications 2 Specifications 2.1 Specifications UDA2182 Universal Dual Analyzer Display Graphical LCD with white LED Backlight Viewing Area: 66.8 mm (W) X 35.5 mm (H) Dot Pixels: 128 (W) X 64 (H) Display Ranges pH: 0-14 pH Temperature: -10 to 110°C (14 to 230°F) ORP: -1600 to +1600 mV Conductivity: 0.01 Cell: 0-2 uS/cm displayable to 200 uS/cm; 0-0.2 mS/cm; 0-2,000 ppb TDS; 0-200 ppm TDS 0.1 Cell: 0-20 uS/cm displayable to 2000 uS/cm; 0-2 mS/cm, 0-2,000 ppb TD
ページ18に含まれる内容の要旨
Specifications UDA2182 Universal Dual Analyzer Control Loop/Outputs Control Loops: 2 standard (one for each PV); current, pulse frequency, or time proportional Control Loop Types: PID (optional), Duplex (optional), On/Off (standard) Auto-tuning: Accutune II, fuzzy logic overshoot suppression, applicable to both PID loops Standard Alarm/ Control Two SPDT (Form “C”) Relays Relays Resistive Load Rating: 4A, 120/240 Vac Optional Additional Two SPDT (Form “C”) Relays Alarm/Control Relays
ページ19に含まれる内容の要旨
Specifications UDA2182 Universal Dual Analyzer Ethernet TCP/IP Type: 10 or 100 BaseT; auto-speed and auto-polarity sensing Communications Interface Length of Link: 330 ft. (100 m) maximum. Use Shielded twisted-pair, Category 5 (STP CAT5) Ethernet (Optional) cable. Link Characteristics: Four-wire plus shield, single drop, five hops maximum IP Address: IP Address is 192.168.1.254 as shipped from the factory Recommended network configuration: Use Switch rather than Hub in order to maximiz
ページ20に含まれる内容の要旨
Specifications ATTENTION The emission limits of EN61326 are designed to provide reasonable protection against harmful interference when this equipment is operated in an industrial environment. Operation of this equipment in a residential area may cause harmful interference. This equipment generates, uses, and can radiate radio frequency energy and may cause interference to radio and television reception when the equipment is used closer than 30 meters (98 feet) to the antenna (e). In s