ページ1に含まれる内容の要旨
Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation Selection of Installation Place
● Torque wrench
● Driver
Indoor Unit
(17mm,22mm,26mm)
● Nipper
● Place, robust not causing vibration, where the body can be supported suf ficiently.
● Hacksaw ● Pipe cutter
● Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
● Hole core drill ● Flaring tool
unit are not disturbed.
● Spanner(17,19 and 26mm) ● Knife
● Place, possible to
ページ2に含まれる内容の要旨
1. Insert the drain hose into the dent of heat insulation materials of indoor unit. Accessory parts 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Remote controller (1) Drain hose (1) Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Cushion (4) R-03 dry battery (2) Indoor/outdoor electric cabl
ページ3に含まれる内容の要旨
(L) 2(N) 1 3 1 2 4 5 L N Outdoor unit 1 Installation of Outdoor Unit outdoor units Install according to Drawing for the installation of indoor and 2 Connection of pipes ● To bend a pipe, give the roundness as large as possible not to crush the pipe , Indoor unit POWER and the bending radius should be 30 to 40 mm or longer. ● Connecting the pipe of gas side first makes working easier. ● The connection pipe is specialized for R410A. Outdoor unit Forced fastening without careful centering may Half u
ページ4に含まれる内容の要旨
After 6 seconds, close the 2-way valve and make the inspection of gas leakage. Correct Incorrect 5. No gas leakage? In case of gas leakage, tighten parts of pipe connection. If Lean leakage stops, then proceed 6. steps Damage of flare Crack Partial Too outside If it does not stop gas leakage, discharge whole refrigerants from the service port. After flaring work again and vacuumize, fill up prescribed 3 On Drainage refrigerant from the gas cylinder. Please install the drain hose so as to be downwar