4. Use the mounting screw provided to loosely install the edge
Contents
guide standoff in the lower mounting hole in the appropriate
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
space to the left of the control panel (Figure 2). Do not
Internal mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
tighten the mounting screw
ページ2に含まれる内容の要旨
2 NetworX NX-548E Receiver Installation Instructions 6. Align the bottom of the circuit board in the edge guide Mounting standoff and twist the standoff into place (Figure 4). Tighten The module can be mounted on any interior wall (protected from the mounting screw (Figure 2). the elements). To mount the module, do the following: 1. Remove the module back plate from the packaging. Figure 4. Installing the circuit board 2. Hold the base against the mounting surface and mark the two mounting
ページ3に含まれる内容の要旨
3 9. To install the circuit board onto the back plate (Figure 7), DIP switch settings insert the antennas into the antenna shrouds, then gently The DIP switches (Figure 7) on the circuit board are used to set slide the top of the circuit board under the two top latches, the receiver module number. Use Table 2 to set the DIP switches and snap the circuit board in at the bottom latch to secure it to the desired module number. in place. Table 2. DIP switch settings Module number 32 Module
ページ4に含まれる内容の要旨
4 NetworX NX-548E Receiver Installation Instructions 7. Enter the zone number (1 through 192) and press *. Three Programming beeps from the keypad indicate an entry error. This occurs if This section describes how to program the units. you enter a transmitter number that is not within the receiver’s zone block or if the location already has a sensor Programming guidelines learned into it. Use the following programming guidelines: Note: If you change your mind about your entry, terminate •
ページ5に含まれる内容の要旨
5 UFT settings Transmitter options Use the following guidelines when setting features 4, 5 and 7 LCD touchpads will display instructions when accomplishing (see Segment 1 in Table 5 on page 7) for UFTs: tasks. • Feature 4 - Input option 1. For UFTs, turn on this feature to To program the transmitter and partition settings, do the disable the transmitter’s primary reed. following: • Feature 5 - Input option 2. For UFTs on this feature to 1. Enter * 8 at the keypad. On LED touchpads, the five
ページ6に含まれる内容の要旨
6 NetworX NX-548E Receiver Installation Instructions Transmitter supervision windows Delete transmitters LCD touchpads will display instructions when accomplishing tasks. LCD touchpads will display instructions when accomplishing tasks. To change the transmitter supervision windows, do the following: The following section describes how to delete transmitters from the receiver. 1. Enter * 8 at the keypad. On LED touchpads, the five func- tion lights start flashing. Note: This procedure makes t
ページ7に含まれる内容の要旨
7 Table 5. Programming settings (continued) Programming settings table Location Segment 1 Segment 2 Table 5. Programming settings Zone _____ 1 - Enable sensor Partition 1 keyfob Location Segment 1 Segment 2 2 - Supervised Partition 2 keyfob Assigned to module 3 - Fire supervision Partition 3 keyfob 0 None None #_____. 4 - Input option 1 Partition 4 keyfob (Transmitter to 5 - Input option 2 Partition 5 keyfob program) RM HE P 6 - 80-bit device Partition 6 keyfob 7 - Input option 3
ページ8に含まれる内容の要旨
8 NetworX NX-548E Receiver Installation Instructions Table 5. Programming settings (continued) Table 5. Programming settings (continued) Location Segment 1 Segment 2 Location Segment 1 Segment 2 Zone _____ 1 - Enable sensor Partition 1 keyfob Zone _____ 1 - Enable sensor Partition 1 keyfob 2 - Supervised Partition 2 keyfob 2 - Supervised Partition 2 keyfob Assigned to module Assigned to module 3 - Fire supervision Partition 3 keyfob 3 - Fire supervision Partition 3 keyfob #_____. #_____. 4 -
ページ9に含まれる内容の要旨
9 Table 5. Programming settings (continued) Table 5. Programming settings (continued) Location Segment 1 Segment 2 Location Segment 1 Segment 2 Zone _____ 1 - Enable sensor Partition 1 keyfob Zone _____ 1 - Enable sensor Partition 1 keyfob 2 - Supervised Partition 2 keyfob 2 - Supervised Partition 2 keyfob Assigned to module Assigned to module 3 - Fire supervision Partition 3 keyfob 3 - Fire supervision Partition 3 keyfob #_____. #_____. 4 - Input option 1 Partition 4 keyfob 4 - Input option
ページ10に含まれる内容の要旨
10 NetworX NX-548E Receiver Installation Instructions Table 5. Programming settings (continued) Table 5. Programming settings (continued) Location Segment 1 Segment 2 Location Segment 1 Segment 2 Zone _____ 1 - Enable sensor Partition 1 keyfob 193 1 - Enable jam detect None Receiver options (all 2 - Supervised Partition 2 keyfob 2 - Enable auto defaults off) Assigned to module advance to next 3 - Fire supervision Partition 3 keyfob #_____. zone number 4 - Input option 1 Partition 4 keyfob
ページ11に含まれる内容の要旨
11 Table 5. Programming settings (continued) Supported devices For 80-bit devices, Feature 6 must be on for Segment 1 on zone Location Segment 1 Segment 2 location. For 63-bit devices, Feature 6 must be off for Segment 1 200 None None on zone location. Number of rounds 80-bit devices received from last transmitter learned • 60-849-02-95 ESL Smoke Detector See Testing and trou- • 60-917-95 Universal Fire Transmitter bleshooting on page 6. • 60-832-95R 2 Button Keychain Touchpad * 63-bit devic
ページ12に含まれる内容の要旨
12 NetworX NX-548E Receiver Installation Instructions Specifications FCC compliance This device complies with part 15 of the FCC rules. Operation is subject to the Compatibility NX-4, NX-6, NX-8, NX-8E control panels following conditions: Frequency 319.5 MHz 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference Wireless range 1,000 feet (304 m) that may cause undesired operation. Required power 12.0 VDC (provided by