ページ1に含まれる内容の要旨
SISTM10xx-162-LR(T)
(6) 10/100Base-TX + (2) 100Base-FX
Industrial Managed Switch
Installation Manual
Rev. 1
25-October-2007
ページ2に含まれる内容の要旨
Notice This manual contents are based on the below table listing software kernel version, hardware version, and firmware version. If the switch functions have any different from the manual contents description, please contact Transition Networks for more information. Firmware Version v1.02 Kernel Version v3.22 Hardware Version A5.00 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules.
ページ3に含まれる内容の要旨
Contents Notice........................................................................................................................................... 1 FCC Warning ............................................................................................................................... 1 CE Mark Warning ........................................................................................................................ 1 Introduction .........................................
ページ4に含まれる内容の要旨
Port status.................................................................................................................................. 17 Single Port Information ........................................................................................................ 18 Port Statistics............................................................................................................................. 18 Port Control..............................................................
ページ5に含まれる内容の要旨
Save Configuration .................................................................................................................... 44 Rate Control............................................................................................................................... 44 System Log................................................................................................................................ 45 System Log Configuration...............................................
ページ6に含まれる内容の要旨
Introduction The SISTM10xx-162-LRx Managed Industrial Switch is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. The switch can be easily managed through the Web GUI. By using fiber port can extend the connection distance that increases the network elasticity and performance. It also provides the X-Ring function that can prevent the network connection failure. Features • Conform to IEEE 802.3 10Base-T, 802.3u 100Base-TX/1
ページ7に含まれる内容の要旨
Package Contents Please refer to the package content list below to verify them against the checklist. • SISTM10xx-162-LRx Managed Industrial Switch • DC Jack 2.0/150mm RoHS • User manual CD • DIN-Rail Bracket (attached on the switch) • One wall mount plate and six screws SISTM10xx-162-LRx DC Jack 2.0/150mm RoHS User Manual CD Wall Mount Plate Screws DIN-Rail Bracket (installed
ページ8に含まれる内容の要旨
Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. Physical Dimension 54mm (w) x 135mm (h) x 105mm (d) Front Panel The Front Panel of the SISTM10xx-162-LRx Managed Industrial Switch is shown below: Reset Button The reset button provides user a quick and easy way to restart and set the configuration back to default value. • Restart: press the button for 2 seconds a
ページ9に含まれる内容の要旨
set all configurations back to default setting Bottom View The bottom view of the switch is shown below: Grounding Screw 6-position terminal block Primary power input terminals (2) Secondary power input Contact relay output terminals (2) DIP-switch The switch provides the 9 DIP-switch for configuring the relay alarm operation mode and the master ring operation mode. The default value of Dipswitch is OFF. DIP Switch No Status Description OFF Disable port 1
ページ10に含まれる内容の要旨
OFF Disable port Alarm 5 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable port Alarm 6 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable port Alarm 7 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable port Alarm 8 Enable port Alarm. If the port’s link fails, the fault ON LED will light up OFF Disable the ring master function 9 Enable the switch as the ring mas
ページ11に含まれる内容の要旨
Off No power inputs Power failure or UTP port failure or Fiber port Yellow failure Fault No Power failure or UTP port failure or Fiber port Off failure occurs The industrial switch is the master of X-Ring Green group R.M. (Ring Master) The industrial switch is not a ring master in X- Off Ring group Green The port is linking LNK/ACT The port is transmitting or receiving packets Blinks (Fiber port) from the TX device Off No device attached Yellow The port is operating in ful
ページ12に含まれる内容の要旨
All ports on this industrial switch support automatic MDI/MDI-X operation, user can use straight- through cables (See figure below) for all network connections to PCs or servers, or to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below shows the 10BASE- T/100BASE-TX MDI and MDI-X port pin outs. Pin MDI-X Signal Name MDI Signal Name 1 Receive Da
ページ13に含まれる内容の要旨
ATTENTION This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED Beam. Cabling • Using four twisted-pair, Category 5 cabling for RJ-45 port connection. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long. • Fiber segment using single-mode connector type must use 9/125 um single-mode fiber cable. User can connect two devices in the distance up to 30 Kilometers. • Fiber segment using
ページ14に含まれる内容の要旨
Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as below figure shows. By inserting the wires and set the DIP switch at “ON” status, it will detect the fault status which the power is failure or port link failure and form an open circuit. And, application example for the fault alarm contact as below: 1A@24V Insert the wires into the fault alarm contact [NOTE] The wire range of terminal block is from 12~ 24 AWG. Fault Ala
ページ15に含まれる内容の要旨
Mounting Installation DIN-Rail Mounting The DIN-Rail is screwed on the industrial switch when out of factory. 1. First, insert the top of DIN-Rail into the track. 2. Then, lightly push the DIN-Rail into the track. 10
ページ16に含まれる内容の要旨
3. Check the DIN-Rail is tightly on the track. 4. To remove the industrial switch from the track, reverse steps above. Wall Mount Plate Mounting Follow the below steps to mount the industrial switch with wall mount plate. 1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail. 2. Place the wall mount plate on the rear panel of the industrial switch. 3. Use the screws to screw the wall mount plate on the industrial switch. 4. Use the hook holes
ページ17に含まれる内容の要旨
Hardware Installation Installation Steps 1. Unpacking the Industrial switch 2. Check the DIN-Rail is screwed on the Industrial switch. If the DIN-Rail is not screwed on the Industrial switch. Please refer to DIN-Rail Mounting section for DIN-Rail installation. If user want to wall mount the Industrial switch, then please refer to Wall Mount Plate Mounting section for wall mount plate installation. 3. To hang the Industrial switch on the DIN-Rail track or wall, please refer to the
ページ18に含まれる内容の要旨
Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application. A sample application of the industrial switch is as below: 13
ページ19に含まれる内容の要旨
X-Ring Application The industrial switch supports the X-Ring protocol that can help the network system to recovery from network connection failure within 300ms or less, and make the network system more reliable. The X- Ring algorithm is like as spanning tree protocol (STP) algorithm but it has faster recovery time than STP. The following figure is a sample X-Ring application. 14
ページ20に含まれる内容の要旨
Coupling Ring Application In the network, it may have more than one X-Ring group. By using the coupling ring function can connect each X-Ring for the redundant backup. It can ensure the transmissions between two ring groups will no failure. The following figure is a sample of coupling ring application. Dual Homing Application Dual Homing function is to prevent a lost connection between X-Ring group and upper level/core switch. Assign two ports to be the Dual Homing port that is