ページ1に含まれる内容の要旨
ESX-1320/ESX-1380
INSTALLATION GUIDE
MULTI PORT ETHERNET SWITCH
ESX-1320 ™ ®
WITH FDSE AND LANVIEW
STY XMT
LNK RCV
BRIM-A100
PWR RECEIVE
CPU TRANSMIT
DISPLAY RESET
12 3 4 5 6 7 8 9 10 1112 PORT
COM 2 COM 1
1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X
MULTI PORT ETHERNET SWITCH
ESX-1380 ™ ®
WITH FDSE AND LANVIEW PORT 9 PORT 10 PORT 11 PORT 12
STY XMT
RX TX RX TX RX TX RX TX
LNK RCV
BRIM-A100
PORT 5 PORT 6 PORT 7 PORT 8
PORT 1 PORT 2 PORT 3 PORT 4
RX TX RX TX RX TX RX TX
PWR RECEIVE RX TX RX TX RX TX
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABL
ページ4に含まれる内容の要旨
Notice DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. VCCI NOTICE
ページ5に含まれる内容の要旨
Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This
ページ6に含まれる内容の要旨
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir
ページ7に含まれる内容の要旨
CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual....................................................................... 1-2 1.2 Features ...................................................................................... 1-2 1.3 Document Conventions ............................................................... 1-5 1.4 Related Manuals.......................................................................... 1-5 1.5 Getting Help..................................................
ページ8に含まれる内容の要旨
Contents CHAPTER 4 TROUBLESHOOTING 4.1 Using LANVIEW...........................................................................4-1 4.2 Troubleshooting Checklist............................................................4-4 4.3 Using the RESET Button .............................................................4-6 4.4 Using the LCD..............................................................................4-7 4.4.1 Unsaved Initialization Messages.....................................4-
ページ9に含まれる内容の要旨
CHAPTER 1 INTRODUCTION Welcome to the Cabletron Systems ESX-1320/ESX-1380 Installation Guide for the ESX-1320 and ESX-1380 Ethernet Workgroup Switches. This manual describes the ESX-1320 and ESX-1380 switches and provides information concerning installation and troubleshooting. The ESX-1320 and ESX-1380 Ethernet Workgroup Switches, shown in Figure 1-1, are standalone network switch devices. Except for the difference in the network media supported (ESX-1320, RJ45 Twisted Pair port
ページ10に含まれる内容の要旨
Chapter 1: Introduction 1.1 USING THIS MANUAL You should have a general working knowledge of Ethernet or IEEE 802.3 type data networks and their physical layer components, prior to installing the ESX. The following summarizes the organization of this manual. Chapter 1, Introduction, provides instructions for using this manual, product features, document conventions, related documents, and how to contact Cabletron Technical Support. Chapter 2, Controls and Indicators,
ページ11に含まれる内容の要旨
Features Connectivity The ESX-1320 switch connects to the external Ethernet networks or workstations through the 12 standard RJ45 connectors on its front panel. The RJ45 connectors (interface ports) support Unshielded Twisted Pair (UTP) and Shielded Twisted Pair (STP) cabling at lengths up to 100 meters. The ports are IEEE 802.3 10BASE-T compliant. The ESX-1380 switch connects to the external Ethernet networks or workstations through the 12 Fiber Optic ST connectors on its front p
ページ12に含まれる内容の要旨
Chapter 1: Introduction Management The ESX can be managed using Local Management (LM) tools or remote SNMP management stations. Out-of-band Local Management is provided through RS232 COM ports on the front panel using a standard VT220 or VT320 terminal or emulator. In-band remote management is possible through any SNMP compliant Network Management System (NMS). Traditional Switching The ESX provides Traditional Switching or future SECUREFAST Switching Virtual Network S
ページ13に含まれる内容の要旨
Related Manuals Note symbol. Calls the reader’s attention to any item of NOTE information that may be of special importance. Tip symbol. Conveys helpful hints concerning procedures or actions. TIP Caution symbol. Contains information essential to avoid damage to the equipment. ! CAUTION Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard. 1.4 RELATED MANUALS The following manu
ページ14に含まれる内容の要旨
Chapter 1: Introduction FTP ctron.com (134.141.197.25) Login anonymous Password your email address BBS (603) 335-3358 Modem setting 8N1: 8 data bits, 1 stop bit, No parity For additional information about Cabletron Systems products, visit our World Wide Web site: http://www.cabletron.com/ Before calling Cabletron Systems Technical Support, have the following information ready: • A description of the failure • A description of any action(s) already taken to resolve the problem (e.g.,
ページ15に含まれる内容の要旨
CHAPTER 2 CONTROLS AND INDICATORS This chapter provides descriptions of the controls and indicators for the ESX-1320 and ESX-1380 Ethernet Workgroup Switches shown in Figure 2-1. MULTI PORT ETHERNET SWITCH ESX-1320 WITH FDSE™AND LANVIEW® STY XMT LNK RCV BRIM-A100 PWR RECEIVE DISPLAY RESET CPU TRANSMIT 12 3 4 5 6 7 8 9 10 1112 PORT COM 2 COM 1 1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X MULTI PORT ETHERNET SWITCH ESX-1380 WITH FDSE™AND LANVIEW® PORT 9 PORT 10 PORT 11 PORT 12 STY XMT RX TX RX TX RX T
ページ16に含まれる内容の要旨
Chapter 2: Controls and Indicators 2.3 LCD DISPLAY The ESX is equipped with an LCD display located on the front panel. The LCD provides status information about the present as well as past conditions of the ESX. You can view power up diagnostics, firmware revisions, MAC addresses, IP addresses, and alarm messages. The LCD displays the most current event, but can store up to 25 past events in memory. Chapter 4 provides details about the LCD Display. 2.4 NETWORK MANAGEMENT CAPABILITIES You ca
ページ17に含まれる内容の要旨
Simplex or Full Duplex Mode Operation To set a port for full duplex operation using MIB Navigator, proceed as follows: 1. Access Local Management as described in the ESX-1320/ESX-1380 Local Management Guide. 2. Select MIB Navigator via the Local Management Main Menu screen. The MIBNav -> prompt appears. 3. Enter the following commands (shown in bold type) at the MIBNav -> prompt as shown below: MIBNav -> ctron MIBNav -> cd 4/3/3/2/1/1 MIBNav -> set 5[x] y where x equals the port number (1 th
ページ18に含まれる内容の要旨
Chapter 2: Controls and Indicators 2-4 ESX-1320/ESX-1380 Installation Guide
ページ19に含まれる内容の要旨
CHAPTER 3 INSTALLATION This chapter provides the instructions to install and connect the ESX to the network. It includes the following procedures: • Unpacking the ESX (Section 3.1) • Removing the chassis cover (Section 3.2) • Locating and setting the mode switches (Section 3.3) • Using the NVRAM reset switch (Section 3.4) • Adding/replacing Single In-line Memory Modules (SIMMs) (Section 3.5) • Identifying the BRIM connector location (Section 3.6) • Installing the ESX on a shelf or into a stand
ページ20に含まれる内容の要旨
Chapter 3: Installation 3.1 UNPACKING THE ESX Unpack the ESX as follows: 1. Remove the shipping material covering the ESX. 2. Verify the contents of the packing carton. The carton, as shipped, should contain the following items: • ESX-13XX • Firmware Images, 2 • Grounding strap • RJ45 Adapter Kit • Release Notes • Rack Mounting Kit • Accessory Kit • ESX-1320/ESX-1380 Installation Guide • ESX-1320/ESX-1380 Local Management Guide 3. If any of these items are missing, contact Cabletron Systems Tec