Multi Room Audio Amplifier Installation Instructions Contents 1 Introduction 3 1.1 Product Range 3 1.2 Safety and Product Handling 4 1.3 Additional Product Information 6 2 Installation 7 2.1 Installation Steps 7 2.2 Equipment Placement 8 2.3 Wiring Diagrams 9 3 Wiring Details 11 3.1 Speaker Connections 11 3.2 C-Bus Network Cabling 12 3.3 Stereo Input Connection 13 3.4 Digital Audio Cabling for Multiple Amplifiers 13 4 Power Supply Connection 14 5 Commissioning and
ページ3に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 1 Introduction The installation instructions cover a 'standalone' Multi Room Audio (MRA) amplifier installation without a matrix switcher. A standalone amplifier configuration includes connections to a power supply, loudspeakers and a local stereo audio source. You can also connect additional MRA amplifiers using digital audio cables. If you are installing a Multi Room Audio system that includes a matrix switcher, refer to the informat
ページ4に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions Power Supplies Each Multi Room Audio Amplifier in a standalone installation requires a power supply (See Table 2) connected to the amplifier's EXTERNAL POWER socket. Catalogue Number Description 5600P24/3750AU Switch Mode Power Supply, 24 V d.c. @ 3.75 A. Suits the 560125D/2 Desktop and the 560125R/2 Remote Amplifiers. 5600P24H3750A High Temperature Switch Mode Power Supply, 24 V d.c. @ 3.75 A. Required for all high temperature locat
ページ5に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions • Turn down the volume setting before connecting headphones. Connect the headphones to the amplifier BEFORE placing them on your head. • Do not allow children to use the Multi Room Audio equipment without adequate supervision. Cautions Prevent damage to the equipment and extend its useful life by following these guidelines: • Only use a Clipsal approved power supply to power an amplifier. Using any other power supply can damage the u
ページ6に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 1.3 Additional Product Information If you have technical questions about the installation of the Multi Room Audio equipment, contact your nearest Clipsal Integrated Systems or Schneider Electric customer care centre. The contact information is on the back cover of this document. Related Documents The C-Bus Multi Room Audio Amplifier User's Guide contains instructions for using the amplifiers in a standalone installation. The C-Bus Mu
ページ7に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 2 Installation This document covers the standalone audio amplifier installation without a matrix switcher. Installing multiple amplifiers is discussed in this document. If you need additional details about the amplifier's features or connections, refer to the MRA system-level documents listed previously. 2.1 Installation Steps The following table gives you an overview of the installation process flow. Step Description Read safety in
ページ8に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 2.2 Equipment Placement When installing the amplifier and its speakers, you should choose a location that is close to the audio input source and a wall power outlet for the amplifier. Doing so will minimise cabling issues. Proximity to the C-Bus input units that control the amplifier should be considered as well. You should consider the following factors when choosing a location for the amplifier and speakers. Be sure that: • there i
ページ9に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 2.3 Wiring Diagrams Wiring diagrams are provided for typical installations using one amplifier (Figure 1) and more than one amplifier (Figure 2). Note that multiple amplifiers have one analogue input source and a digital audio connection between the amplifiers. When making wiring connections, it is important to follow these guidelines: • Do not plug a C-Bus network cable into a Digital Audio socket. You could damage the amplifier. • C
ページ10に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions Figure 2. Two amplifiers connected to a single audio source. Note for Figure 2. You can continue to connect Digital Audio cables to additional amplifiers. The analogue input, LOCAL IN, is connected to the first amplifier. Clipsal offers the following cable and connectors: Catalogue Number Description 5005C305B (solid) C-Bus network cable, Cat.5e, 4 pair, UTP cable, colour: 5005C305BST (stranded) Pink RJ88P Modular plug, 8 way, Cat
ページ11に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 3 Wiring Details Use high quality cables and connectors for best results. Make sure that all connections are tight and that no strands of wire are protruding from the connectors. Bootlace crimps are recommended for twisted network cable connections. 3.1 Speaker Connections The high power MRA amplifiers use spring-type connectors. The Low Power Remote Amplifier uses a screw-type connector. Use low-impedance, stranded speaker cable to
ページ12に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 3.2 C-Bus Connection Each amplifier has a connection to the C-Bus network. C-Bus wall switches control the volume, bass and treble settings for the amplifier via the C-Bus network. C-Bus Toolkit configuration software is used to configure wall switches to control the amplifiers. Refer to the C-Bus Multi Room Audio Amplifier User's Guide, the wall switch documents, and C-Bus Toolkit Help. The C-Bus network cables for the 560125D/2 and 5
ページ13に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 3.3 Stereo Input Connection The rear panel connectors for the local audio input are labelled LOCAL IN. See Figure 5. The high power amplifiers use RCA sockets and the low power amplifier uses a 3.5 mm stereo socket. The LOCAL IN is for connection to line level signals, normally labelled Audio Output on source devices. Do not connect high-level speaker outputs from audio source equipment to the LOCAL IN inputs on the MRA amplifier. Thes
ページ14に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 4 Power Supply Connection The 3.75 Amp-rated power supplies have a power cord and the 1.25 Amp-rated power supply is a plug-pack design. If you are using a High Temperature Power Supply with a 560110R Low Power Remote Amplifier, use the cable adapter that is provided with the power supply. Refer to the appropriate power supply instruction sheet. 1. Plug the end of the power supply output cable into the External Power connector on the
ページ15に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 5 Commissioning and Testing Follow these guidelines when testing the functionality of the installation. • Configure the C-Bus wall switches to control the volume, bass/treble and muting before connecting an audio source. Refer to the wall switch instruction documents and to C-Bus Toolkit software Help. • Be sure to power off amplifiers before connecting audio sources or network cables. Mute the speakers before connecting or disconnecti
ページ16に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 7 Specifications 560125D/2 Desktop and 560125R/2 Remote Parameter Description Supply Voltage 24 V DC @ 3.75 A when using the external switch mode power supply 27 V d.c. when powered by the Matrix Switcher (via digital audio connection), refer to the system level documents C-Bus supply voltage 15 to 36 V d.c. C-Bus sink current 22 mA Power consumption 90 W maximum Maximum power output 28 W RMS into 4 Ω (0.514% THD) Frequency respo
ページ17に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 560110R Low Power Remote Parameter Description Supply Voltage 27 V d.c. when powered by the Matrix Switcher (via digital audio connection), and/or 24 V DC @ 1.25A when using the external power supply or switch mode power supply C-Bus supply voltage 15 to 36 V d.c. C-Bus sink current 22 mA Power consumption 30 W maximum Maximum power output 10 W RMS into 4 Ω (0.514% THD) Frequency response 40 Hz to 20 kHz (±1 dB) Total harmonic d
ページ18に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 8 Standards Complied DECLARATIONS OF CONFORMITY Australian/New Zealand EMC & Electrical Safety Frameworks and Standards Regulation Standard Title Electrical Safety * AS/NZS 60065 Audio, video and similar electronic apparatus - Safety requirements EMC AS/NZS CISPR 13 Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics (emissions) When powered by EP1096 or PAC090M Power Supply, Cl
ページ19に含まれる内容の要旨
Multi Room Audio Amplifier Installation Instructions 9 Two-Year Warranty The C-Bus Multi Room Audio Amplifier carries a two-year warranty against manufacturing defects. Warranty Statement The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Schneider Electric product, which the consumer has in the location where the product is sold. The warrantor is Schneide
ページ20に含まれる内容の要旨
Technical Support For further assistance in using this product, consult your nearest Clipsal Integrated Systems (CIS) Sales Representative or Technical Support Officer. Technical Support Contact Numbers Australia 1300 722 247 (CIS Technical Support Hotline) New Zealand 0800 888 219 (CIS Technical Support Hotline) Northern Asia +852 2484 4157 (Clipsal Hong Kong) South Africa 011 314 5200 (C-Bus Technical Support) Southern Asia +603 7665 3555 Ext. 236 or 242 (CIS Malaysia) United Kingdo