ページ1に含まれる内容の要旨
Moxa EtherDevice Switch
EDS-208 Series Hardware Installation Guide
Second Edition, June 2008
© 2008 Moxa Inc., all rights reserved.
Reproduction without permission is prohibited.
P/N: 1802002080000
ページ2に含まれる内容の要旨
Overview The EDS-208 series of Moxa EtherDevice™ Switches are entry-level 8-port Ethernet Switches that provide a cost-effective solution for industrial Ethernet connections. EDS-208 provides a choice of 12 to 45 VDC power input or 18 to 30 VAC. The switches can operate reliably in a temperature range of -10 to 60°C, and the rugged hardware design makes EDS-208 perfect for ensuring that your Ethernet equipment can be used in demanding industrial environments. Package Checklist Moxa ED
ページ3に含まれる内容の要旨
Panel Layout of EDS-208 Top View 1. Heat dissipation orifices 2. Terminal block for power input and grounding 1 3. Moxa Logo V- 4. Power input LED V+ 2 5. 10/100BaseT(X) Port 24 VDC/VAC 6. TP port’s 100 Mbps LED 7. TP port’s 10 Mbps LED 8. DIN-Rail kit Front View 2 P 4 3 7 8 5 6 5 3 4 100 6 1 2 10 7 Rear View 8 - 3 -
ページ4に含まれる内容の要旨
Panel Layout of EDS-208-M-SC/ST Top View 1. Heat dissipation orifices 2. Terminal block for power input and grounding 1 3. Moxa Logo V- 4. Power input LED V+ 2 5. 10/100BaseT(X) Port 24 VDC/VAC 6. TP port’s 100 Mbps LED 7. TP port’s 10 Mbps LED 8. FX port’s 100 Mbps LED 9. 100BaseFX Port 10. DIN-Rail kit Front View 2 3 P 4 100M 8 Rx 8 7 9 Tx 5 6 5 3 4 100 6 1 2 10 7 Rear View 10 - 4 -
ページ5に含まれる内容の要旨
74 100 76.2 15.6 23 100 Mounting Dimensions (unit = mm) 74 15 15 7 32 10.5 P P 40.03 100M Rx 8 7 7 8 Tx V- V+ 12 5 6 5 6 24 VDC/VAC 3 4 3 4 100 100 1 2 1 2 10 10 86.5 40.03 EDS-208 EDS-208-M-SC/ST Side View Front View Rear View Top View DIN-Rail Mounting The plastic DIN-Rail attachment plate should already be fixed to the rear panel of EDS-208 when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to EDS-208, make sure the DIN-Rail kit is situated towar
ページ6に含まれる内容の要旨
Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your EDS-208. Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment. You should also pay attention to the following items: Use separate paths
ページ7に含まれる内容の要旨
Wiring the Power Inputs The two left-most contacts of the 3-contact terminal block connector on EDS-208’s top panel are used for both the DC and AC inputs of EDS-208. Top and front views of one of the terminal block connectors are shown here. STEP 1: Insert the negative/positive DC or AC wires into the V-/V+ terminals. STEP 2: To keep the DC or AC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connecto
ページ8に含まれる内容の要旨
RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring 100BaseFX Ethernet Port Connection The concept behind the SC/ST port and cable is quite straightforward. Suppose you are connecting devices I and II. Contrary to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used to transmit data from device II to device I, for full-duple
ページ9に含まれる内容の要旨
LED Indicators The front panel of EDS-208 contains several LED indicators. The function of each LED is described in the table below. LED Color State Description Power is being supplied to the On power input P AMBER Power is not being supplied to Off the power input On TP port’s 10 Mbps link is active Data is being transmitted at 10 10 Blinking GREEN Mbps (TP) TP Port’s 10 Mbps link is Off inactive On TP port’s 100 Mbps link is active 100 Data is being transmitted at 100
ページ10に含まれる内容の要旨
Switching, Filtering, and Forwarding Each time a packet arrives at one of the switched ports, a decision is made either to filter or to forward the packet. Packets with source and destination addresses belonging to the same port segment will be filtered, constraining those packets to one port, and relieving the rest of the network from the need to process them. A packet with destination address on another port segment will be forwarded to the appropriate port, and will not be sent to the
ページ11に含まれる内容の要旨
Optical Fiber Multi mode Distance 5 km Wavelength, nm 1300 Min. TX Output, dBm -20 Max. TX Output, dBm -14 Sensitivity, dBm -34 to -30 Recommended Diameter (Core/Cladding) μm 50/125 (1 dB/km, 800 MHz × km) Power Input Voltage 12 to 45 VDC, 18 to 30 VAC (47 to 63 Hz) Input Current @ 24 VDC 0.14 A (EDS-208) 0.23 A (EDS-208-M-SC/EDS-208-M-ST) Connection Removable 3-contact Terminal Block Overload Current 1.1 A Protection Reverse Polarity Protection Present Mechanical C
ページ12に含まれる内容の要旨
Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: +1-714-528-6777 Tel: +86-21-5258-9955 Fax: +1-714-528-6778 Fax: +86-10-6872-3958 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0 Tel: +886-2-8919-1230 Fax: +49-89-3 70 03 99-99 Fax: +886-2-8919-1231 - 12 -