ページ1に含まれる内容の要旨
ge.com
Safety Instructions . . . . . . . . .2, 3
Owner’s Manual and
Installation Instructions
Operating Instructions . . . . . .4, 5
Additional Controls . . . . . . . . . . .5
AEE18
Controls . . . . . . . . . . . . . . . . . . . .4
Normal Operating Sounds . . . . .5
Care and Cleaning
Air Filter . . . . . . . . . . . . . . . . . . .6
Grille and Case . . . . . . . . . . . . . .6
Grille Frame Removal . . . . . . . . .6
Outdoor Coils . . . . . . . . . . . . . . .6
Installation Instructions
Through-t
ページ2に含まれる内容の要旨
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS Use this appliance only for its intended If the receptacle does not match the plug, purpose as described in this Owner’s the receptacle must be changed out by a Manual. qualified electrician. This air conditioner must be properly Turn the unit OFF and unplug your air
ページ3に含まれる内容の要旨
Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support ge.com WARNING! EXTENSION CORDS—115-Volt models only Because of potential safety hazards under certain CAUTION: conditions, we strongly recommend against the DO NOT use an extension cord with any of the use of an extension cord. 230/208 volt models. However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance exte
ページ4に含まれる内容の要旨
About the controls on the air conditioner. Features and appearance will vary. TEMP CONTROL MODE CONTROL Controls Temp Control Mode Control The temp control is used to maintain the Hi Cool and Low Cool provide cooling with room temperature. The compressor will different fan speeds. cycle on and off to keep the room at the Hi Heat and Low Heat provide heating with same level of comfort. Turn the knob different fan speeds. clockwise to Cooler (blue) and the indoor Fan Only setting provides air cir
ページ5に含まれる内容の要旨
Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support Additional controls. ge.com Vent Control The vent control is located above the control panels. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some outside air is let into the room. To open the vent, push the lever to the right. To close it, push it to the left. Air Direction—Up and Down Fingertip pressure on the horizontal louvers adju
ページ6に含まれる内容の要旨
Care and cleaning of the air conditioner. Grille and Case Turn the air conditioner off and remove the To clean, use water and a mild detergent. plug from the wall outlet before cleaning. Do not use bleach or abrasives. Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned. Air Filter The air filter behind the front grille should be checked and cleaned at least every 30 days or mo
ページ7に含まれる内容の要旨
Installation Air Conditioner Instructions Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN CAUTION: Do not, under any circumstances, cut or remove the third (ground) prong from the Read these instructions completely power cord. and carefully. Do not change the plug on the power cord of this air conditioner. • IMPORTANT — Save these instructions for local inspector’s use. Aluminum house wiring may present special problems—consult a qualified electrici
ページ8に含まれる内容の要旨
Window Installation Instructions PARTS INCLUDED Window (Appearance may vary) sash seal Left accordion panel Foam top Top window gasket mounting rail Right accordion panel V-support (2) Window locking bracket (2) Bolt (2) & nuts (2) Type A (6) Type B (4) Type C (6) Type D (6) Type E (4) 8
ページ9に含まれる内容の要旨
Window Installation Instructions 1 WINDOW REQUIREMENTS 3 REMOVE THE AIR CONDITIONER FROM THE CASE • These instructions are for a standard double-hung window. You will need to Remove the inlet grille. A modify them for other types of windows. • All supporting parts must be secured to firm wood, masonry or metal. • The electrical outlet must be within reach of the power cord. Remove the filter. B 18″ min. 30″ to 41″ (With accordion panels) Remove the painted screws from each side C and the screw
ページ10に含まれる内容の要旨
Window Installation Instructions PREPARE THE CASE 3 REMOVE THE AIR CONDITIONER 5 FROM THE CASE (cont.) Install the top mounting rail with 4 type B A screws from the inside of the case. Remove the locking screw and locking E bracket from the lower frame. Save to Press firmly to drive the screws into the gasket and through the top mounting rail. reinstall later. Remove the ground screw and save to Top mounting rail F reinstall later. Insert the frames for the accordion panels B into the top mount
ページ11に含まれる内容の要旨
Window Installation Instructions 6 INSTALL THE CASE 6 INSTALL THE CASE IN THE WINDOW IN THE WINDOW (cont.) Carefully slide the case into the window and Extend the left and right accordion panels A F center the case. Lower the window behind to the vertical window sashes. Drill pilot the top mounting rail. Pull the bottom of the holes and attach the top and bottom case forward so that the bottom mounting corners with 4 type D screws. rail is tight against the back of the window Top mounting rai
ページ12に含まれる内容の要旨
Window Installation Instructions 8 INSTALL THE AIR CONDITIONER 8 INSTALL THE AIR CONDITIONER IN THE CASE IN THE CASE (cont.) Make sure the ground Press the grille frame in around the power A E wire is off to the side cord on the right side. Secure the grille with and slide the air the painted screws on each side and the conditioner into the screw in the front that were removed case. Do not push earlier. on the controls or the finned coils. Make Screw sure the air conditioner is firmly seated. S
ページ13に含まれる内容の要旨
Through-the-Wall Installation Instructions—Optional The case may be installed through-the-wall 1 IMPORTANT (cont.) in both existing and new construction. Secure with 14 wood screws anchored at D Read completely, then follow step-by-step. least an inch into the wall support structure. NOTE: Except for the V-support NOTE: Drill pilot holes, if necessary, for assemblies (included), obtain all materials proper installation. If the frame is oversized, locally for mounting the air conditioner use shi
ページ14に含まれる内容の要旨
Before you call for service…Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do Air conditioner The air conditioner • Make sure the air conditioner plug is pushed completely does not start is unplugged into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped the fuse or reset the breaker. Power failure • The unit will automatically re-start in the settings last used after the power
ページ15に含まれる内容の要旨
Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support GE Air Conditioner Warranty. All warranty service provided by our Factory Service Centers, Staple your receipt here. ® or an authorized Customer Care technician. To schedule service, Proof of the original purchase on-line, 24 hours a day, visit us at ge.com, or call 800.GE.CARES date is needed to obtain service (800.432.2737). Have serial number and model number available under the warran
ページ16に含まれる内容の要旨
Consumer Support. GE Appliances Website ge.com Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line. Schedule Service ge.com Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800.GE.CARES (8