ページ1に含まれる内容の要旨
TM
Web Management User Manual
Industrial Managed Ethernet Switch
Version 1.0
This document applied to models of
MSM-508,MSM-508FC/FCS/FT
©
Copyright ICP DAS Co., Ltd., All Rights Reserved.
April 29, 2008
ページ2に含まれる内容の要旨
CONTENTS 1. Web Connection.......................................................................... 2 2. Basic Setting............................................................................... 4 Information................................................................................ 4 Network .................................................................................... 5 Serial Port.................................................................................. 6
ページ3に含まれる内容の要旨
10. Authentication .......................................................................... 22 Account ....................................................................................22 Accessible IP .............................................................................23 Default Setting ..........................................................................24 Reboot Setting ..........................................................................24 April 29,
ページ4に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Managed Switch Web Management Operation This manual will guide you how to configure ICPDAS Managed Switch through web browser. Connection Basic Setting Web Management support two levels of Redundant Setting authentication : administrator level and user level. Port configuration The administrator level allows you to monitor, Relay Alarm configure and control all functions of Web Email Alarm VL
ページ5に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 1. Web Connection The default network setting (factory default setting) of Managed Switch is : IP : 192.168.255.1 Mask : 255.255.0.0 Gateway : 192.168.0.1 Before accessing Managed Switch through web browser, please modify above setting to fit your network environment, you can refer「RS-232 Console Operation」manual for more detail. Following, we will show you how to connect to the Web Management step by step.
ページ6に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual For login to Web Management, your browser must support HTTP authentication. It allows a web browser to provide credentials when making a request. April 29, 2008 3
ページ7に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 2. Basic Setting This chapter describes how to setting the commonly information on your Managed Switch. Information Module Name: : : : Use to specify the Switch Name, and also displayed as the console prompt. Max. 8 characters. Module Information: : : : Use to memo the extra description of the Switch Module. 16 characters max.. Web Server TCP Port: : : : Specify the connection port of the Web Server. Defa
ページ8に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Only MS Series Switch supports a real time clock. For RS Series Switch, the function is invalid. Network IP Address: : : : IP address is an identifier for a device on a TCP/IP network. It is a 32-bit numeric address consisted as four numbers separated by three dots. The range of each number is from 0 to 255. Managed Switch doesn’t support dynamic IP assignment, you have to speci
ページ9に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Mask: : : : The (subnet) MASK is used to determine the subnet of an IP address. Same as the IP address, a MASK contains four bytes (32 bits) and it is often expressed in the dotted-decimal notation. The factory default value is labeled beside the Switch case. MAC Address: : : : MAC Address is a hardware address. It’s a uniquely identifies the device of MAC layer network. The standard (IEEE 802) format for human-read
ページ10に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual COM1 port is the RS232 standard, use for Console Connection. Factory default setting is: Baud Rate : 115200 Data Bit : 8 Parity Check : 0 (None) Stop Bit : 1 COM2 is the RS485 standard, use for Modbus communication. Factory default setting is: Baud Rate : 115200 Data Bit : 8 Parity Check : 0 (None) Stop Bit : 1 Digital Input / Output ICPDAS Managed Switch supports 3 points of digital input / out
ページ11に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 3. Redundant Setting Redundant LAN topology is a structure to provide the link failure recovery and escaping network loops. It allows you to setup the redundant loops for supporting backup connections. Managed Switch offers redundancy options for various functions, it is a highly reliability device provides the fast error detection and keeps the non-stop connections 24 hours a day, 365 days a year. To manage the Mana
ページ12に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Recovery Time Setting Recovery Time (Cyber-Ring Protocol): : : : Recovery time is the duration of connections that from failure occurred to return to normal. This function allows you to assign the recovery time in millisecond (ms), the variable is from 100ms to 1500ms (1.5 sec). Factory default is 300ms. On Cyber-Ring Protocol Mode, user can specify the recovery time manually, and the Managed Switch will calc
ページ13に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Forward Time (STP Protocol): : : : Forward delay is the duration time that packages from pre-forwarding state to forward state. Factory default is 10000ms, the variable is from 4000ms to 30000ms (30 sec). Setting is only available on STP Mode. Maxage Time (STP Protocol): : : : Max age time is the interval that node Switches waiting for hello messages from the Master Switch. It’s 6000ms by factory default, and the va
ページ14に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 4. Port configuration Mirror Mirror Port setting is commonly used to monitor the network traffic, it can help you to collect and trace abnormal packets of each port without interrupting data transmission. User can specify a switch port to receive the packet copies which from another port. STEP 1 Specify a “Monitor Port” that you want to get the packet copies. STEP 2 Specify the ports will be monitore
ページ15に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Trunking This function is used for setting the groups of link aggregation. Port trunking allows user to combine multiple physical ports into a single logical channel. It can increase the link speed and provide the better redundancy availability. Supported groups depend on the total number of switch ports on the equipment. 508 Series Managed Switch supports up to 4 trunking groups. NOTE!! Active trunking funct
ページ16に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Port Port Number Speed Port transmission speed.(10 Mbps/100 Mbps) Duplex Flow Control Mode. Both Half-duplex and Full-duplex modes are supported. Link Port Link status. ON : Link is up ; OFF : Link is down. Cable Checking This function provides a useful tool to detect the quality of cables. Tick the checkbox of Ports and click “Start Check” button, after a moment waiting, system will report the RX and TX
ページ17に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 5. Relay Alarm Managed Switch offer a relay contact output on Terminal Block of the Switch equipment. It is able to connect to a light, buzzer …etc. warning device and notify system failures immediately. We also offer the web tool to configure the relay manually. It’s convenient for you to enable/disable relay warnings since the Switch equipments are far from you. Relay Output This function enables you to conf
ページ18に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 6. Email Alarm ICPDAS Managed Switch can notify you by email when the specified event occurred. This chapter will guide you how to setting the related parameters. Alarm Event setting User can specify system and port events that warning emails will be sent. Power1 ON The status of power1 from OFF turns to ON. Power2 ON The status of power2 from OFF turns to ON. Power1 OFF The status of power1 from ON turns
ページ19に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Email Setting User can select “Disable Alarm Mail” to stop the email alarm sending (factory default). If email alarm is enabled, there are two methods of email report for you select. The first one is: warning mail is sent immediately when events occur. The second is: user can specify the interval time between 1 to 99 hour(s), and system will sending the system report by email every the specified hour(s). Befor
ページ20に含まれる内容の要旨
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Email Record Switch Management can keep the sending date, time and status of each warning emails. But only the latest 50 sending records will be saved. User can click the “Clean Record Table” button to delete all the email sending history. April 29, 2008 17