HP 5120 EI & 5120 SI Switch Series
Installation Guide
Part number: 5998-1773
Document version: 6W102-20121111
ページ2に含まれる内容の要旨
Legal and notice information © Copyright 2012 Hewlett-Packard Development Company, L.P. No part of this documentation may be reproduced or transmitted in any form or by any means without prior written consent of Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNES
ページ3に含まれる内容の要旨
Contents Product overview·························································································································································· 1 5120-24G EI (2 slots)/5120-24G EI TAA (2 slots) panel views·················································································2 5120-48G EI (2 slots)/5120-48G EI TAA (2 slots) panel views·················································································3 5120-24G EI panel views·······
ページ4に含まれる内容の要旨
Installing/removing an interface card (only for the 5120 EI switches)···································································· 41 Installing an interface card··································································································································· 41 Removing an interface card ································································································································· 42 Installing/removing a dedicated C
ページ5に含まれる内容の要旨
CX4 cables····························································································································································· 72 SFP transceiver modules and SFP Stacking Kit (only for the 5120 SI switches)······················································ 73 Appendix C Ports and LEDs ······································································································································75 Ports························
ページ6に含まれる内容の要旨
Product overview The HP 5120 EI Switch Series includes the models in Table 1, and the HP 5120 SI Switch Series includes the models in Table 2. Table 1 Models in the HP 5120 EI Switch Series Type Product code HP description Alias JE066A HP 5120-24G EI Switch 5120-24G EI JE067A HP 5120-48G EI Switch 5120-48G EI HP 5120-24G EI Switch with 2 Interface JE068A 5120-24G EI (2 slots) Slots HP 5120-24G EI TAA Switch with 2 Non-PoE JG245A 5120-24G EI TAA (2 slots) Interface Slots HP 5120-
ページ7に含まれる内容の要旨
IMPORTANT: For regulatory identification purposes, the HP 5120-8G SI, HP 5120-8G-PPoE+ SI, and HP 5120-8G-PoE+ SI products are assigned Regulatory Model Numbers (RMN). The Regulatory Model Numbers for these products are listed below. These regulatory numbers should not be confused with the marketing names HP 5120, or product numbers JG308A, JG310A, and JG309A. Table 3 Regulatory Model Numbers in the HP 5120 8G SI Switch Series Product code RMN HP description JG308A BJNGA-AD0006 HP 5
ページ8に含まれる内容の要旨
(3) Grounding screw (4) Interface card slot 1 (MOD1) (5) Interface card slot 2 (MOD2) NOTE: The 5120-24G EI (2 slots) and 5120-24G EI TAA (2 slots) switches come with the expansion interface card slots covered by filler panels. 5120-48G EI (2 slots)/5120-48G EI TAA (2 slots) panel views Figure 3 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED (3) Console port (4) Seven-segment LED (Unit) (5) Port mode LED (Mode) (6) Syste
ページ9に含まれる内容の要旨
5120-24G EI panel views Figure 5 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet (2) 10/100/1000Base-T Ethernet port LED port (3) SFP port (4) SFP port LED (5) Console port (6) Seven-segment LED (Unit) (7) Port mode LED (Mode) (8) System status LED (PWR) (9) RPS status LED (RPS) (10) Port LED mode switching button Figure 6 Rear panel (1) AC-input power receptacle (2) RPS receptacle (3) Grounding screw (4) “DO NOT REMOVE” label CAUTION: The 5120-24G EI switch does
ページ10に含まれる内容の要旨
5120-48G EI panel views Figure 7 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet (2) 10/100/1000Base-T Ethernet port LED port (3) Console port (4) Seven-segment LED (Unit) (5) Port mode LED (Mode) (6) System status LED (PWR) (7) RPS status LED (RPS) (8) Port LED mode switching button (9) SFP port (10) SFP port LED Figure 8 Rear panel (1) AC-input power receptacle (2) RPS receptacle (with filler panel) (3) Grounding screw (4) “DO NOT REMOVE” label CAUTION: The 5120
ページ11に含まれる内容の要旨
5120-24G-PoE+ EI (2 slots)/5120-24G-PoE+ EI TAA (2 slots) panel views Figure 9 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED (3) 1000Base-X SFP port (4) 1000Base-X SFP port LED (5) Console port (6) Seven-segment LED (Unit) (7) Port mode LED (Mode) (8) System status LED (PWR) (9) RPS status LED (RPS) (10) Interface card 1 status LED (MOD1) (11) Interface card 2 status LED (MOD2) (12) Port LED mode switching button Figure 10
ページ12に含まれる内容の要旨
5120-48G-PoE+ EI (2 slots)/5120-48G-PoE+ EI TAA (2 slots) panel views Figure 11 Front panel 1 2 3 4 5 6 7 8 12 11 10 9 (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED (3) Console port (4) Seven-segment LED (Unit) (5) Port mode LED (Mode) (6) System status LED (PWR) (7) RPS status LED (RPS) (8) Interface card 1 status LED (MOD1) (9) Interface card 2 status LED (MOD2) (10) Port LED mode switching button (11) 1000Base-X SFP port (12) 1000Base-X
ページ13に含まれる内容の要旨
5120-8G SI panel views Figure 13 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 1000Base-X SFP port (3) Console port (4) Port LED (5) Power LED (Power) Figure 14 Rear panel (1) AC-input power receptacle (2) Grounding screw 5120-16G SI panel views Figure 15 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 1000Base-X SFP port (3) Console port (4) Port LED (5) Power LED (Power) Figure 16 Rear panel (1) AC-input power receptacle (2) Grou
ページ14に含まれる内容の要旨
5120-24G SI panel views Figure 17 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 1000Base-X SFP port (3) Console port (4) Port LED (5) Power LED (Power) Figure 18 Rear panel (1) AC-input power receptacle (2) Grounding screw 5120-48G SI panel views Figure 19 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED (3) Console port (4) Power LED (Power) (5) 1000Base-X SFP port (6) 1000Base-X SFP port LED Figu
ページ15に含まれる内容の要旨
5120-8G-PPoE+ SI panel views Figure 21 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) Port LED mode switching button (3) Port LED (4) Power LED (Power) (5) Port mode LED (6) Console port (7) 1000Base-X SFP port Figure 22 Rear panel (1) AC-input power receptacle (2) Grounding screw 5120-8G-PoE+ SI panel views Figure 23 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) Port LED mode switching button (3) Port LED (4) Power LED (Power) (5) Po
ページ16に含まれる内容の要旨
Figure 24 Rear panel (1) AC-input power receptacle (2) Grounding screw 5120-24G-PPoE+ SI panel views Figure 25 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) Port LED mode switching button (3) Port LED (4) Power LED (Power) (5) Port mode LED (6) Console port (7) 1000Base-X SFP port Figure 26 Rear panel (1) AC-input power receptacle (2) Grounding screw 11
ページ17に含まれる内容の要旨
5120-24G-PoE+ SI panel views Figure 27 Front panel (1) 10/100/1000Base-T auto-sensing Ethernet port (2) Port LED mode switching button (3) RPS status LED (RPS) (4) Port LED (5) Power LED (Power) (6) Port mode LED (7) Console port (8) 1000Base-X SFP port Figure 28 Rear panel (1) DC receptacle (2) Screw hole of the plug (3) AC-input power receptacle (4) Grounding screw 12
ページ18に含まれる内容の要旨
Preparing for installation Safety recommendations To avoid any equipment damage or bodily injury caused by improper use, read the following safety recommendations before installation. Note that the recommendations do not cover every possible hazardous condition. • Before cleaning the switch, unplug all power cords. Do not clean the switch with wet cloth or liquid. • Do not place the switch near water or in a damp environment. Prevent water or moisture from entering the switch chassis.
ページ19に含まれる内容の要旨
Cleanness Dust buildup on the chassis may result in electrostatic adsorption, which causes poor contact of metal components and contact points, especially when indoor relative humidity is low. In the worst case, electrostatic adsorption can cause communication failure. Table 4 Dust concentration limit in the equipment room Substance Concentration limit (particles/m³) 4 Dust ≤ 3 x 10 (no visible dust on the tabletop over three days) NOTE: Dust diameter ≥ 5 μm The equipment room must
ページ20に含まれる内容の要旨
Installation tools • Flathead screwdriver • Phillips screwdriver • Needle-nose pliers • Wire-stripping pliers • Diagonal pliers • ESD-preventive wrist strap • Blow dryer All these installation tools are user supplied. 15