ページ1に含まれる内容の要旨
®
4x1 DVIKVM DL/SL
Switcher
EXT-DVIKVM-441DL
User Manual
www.gefen.com
ページ2に含まれる内容の要旨
ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru Friday PST Write To: Gefen Inc. c/o Customer Service 20600 Nordhoff St Chatsworth, CA 91311 www.gefen.com support@gefen.com Notice Gefen Inc. reserves the right to make changes in the hard ware, packaging and any accompanying doc u men ta tion without prior written notice. 4x1 DVI KVM DL/SL Switcher is a trademark of Gefen Inc. © 20
ページ3に含まれる内容の要旨
CONTENTS 1 Introduction 2 Operation Notes 3 Features 4 Panel Layout 5 Panel Descriptions 6 Connecting and Operating The 4x1 DVI KVM DL/SL Switcher 7 RMT-4IR Remote Control Description 8 4x1 DVI KVM DL/SL Switcher Remote Installation 9 RMT-4IR Remote and 4x1 KVM Switcher Confi guration 10 EDID Modes 12 DL (Dual Link) Only Modes 13 RS-232 Serial Control 14 RS-232 Serial Control Commands 14 EDID Management 20 Routing Commands 22 Rack Mount Installation 23 Specifi cations 24 War
ページ4に含まれる内容の要旨
INTRODUCTION Congratulations on your purchase of the 4x1 DVI-DL KVM DL/SL Switcher. Your complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive computer and electronics add-on solutions that harness integration, extension, distribution and conversion technologies. Gefen’s reliable, plug-and-play products supplement cross-platform computer systems, professional audio/video environments and HDTV systems of all sizes with hard-working solutions that are eas
ページ5に含まれる内容の要旨
OPERATION NOTES READ THESE NOTES BEFORE INSTALLING OR OPERATING THE GEFEN 4X1 DVI KVM DL/SL SWITCHER • The 4x1 DVI KVM DL/SL Switcher will take any of up to four (4) DVI dual- link or single-link resolution inputs and switch them, one at a time, to a DVI output device such as a display/monitor or projector. Resolutions can be up to 3840x2400. • The 4x1 DVI KVM DL/SL Switcher is housed in a metal box for better RF shielding. • By default, the EDID of the attached display is copied to all the
ページ6に含まれる内容の要旨
FEATURES Features • Switches easily between any four DVI-SL or DVI-DL sources with USB 2.0 and audio. • Switches USB 2.0, keyboard & mouse, and analog audio • Maintains highest resolution dual link and single link DVI • Supports either PC or Mac USB keyboard/mouse • Supports resolutions up through 1920x1200 and 3840x2400 • Extends the range of DVI video up to 50 feet • Discrete IR remote control included • Serial RS-232 remote port for switching via automa
ページ7に含まれる内容の要旨
PANEL LAYOUT Front Panel 1 2 3 4 5 Back Panel 6 7 8 9 10 13 11 12 4
ページ8に含まれる内容の要旨
PANEL DESCRIPTIONS 1 External IR Port For connection of external IR extension device such as the Gefen IR Extender (part # EXT-RMT-EXTIR). 2 IR Receiver Receives IR signal from the handheld Infrared remote control unit included with the 4x1 DVI KVM DL/SL Switcher. 3 DVI Signal Status LEDs 1-4 Provide visual confi rmation of the currently selected DVI input signal being output to the DVI display device. 4 DVI Input Selector Push-button switch cycles the next DVI input 1-4 in a forward sequence
ページ9に含まれる内容の要旨
CONNECTING AND OPERATING THE 4X1 DVI KVM DL/SL SWITCHER How to Connect the 4x1 DVI KVM DL/SL Switcher 1. Connect your computers’ DVI, USB, and Audio sources to the 4x1 DVI KVM DL/SL Switcher inputs using user-supplied cables. 2. Connect your USB and audio devices to the USB and audio outputs using user-supplied cables. 3. Connect your DVI display to the DVI output of the 4x1 DVI KVM DL/SL Switcher using a user-supplied DVI cable. 4. Turn on the DVI display or projector fi rst, then the DVI vi
ページ10に含まれる内容の要旨
RMT-4IR REMOTE CONTROL DESCRIPTION LED Indicator Input Selection Buttons The RMT-4IR remote control will allow the user to choose which of the 4 DVI sources or computers will be selected. Please use the information below when selecting the desired source: RMT-4IR Button DVI Source 11 22 33 44 7
ページ11に含まれる内容の要旨
4X1 DVI KVM DL/SL SWITCHER REMOTE INSTALLATION To use the RMT-4IR remote, remove the battery cover on the back of the remote to reveal the battery compartment. Insert the included battery into the open battery slot. The positive (+) side should be facing up. Ensure that both DIP (Dual Inline Package) switches are in the OFF position. Replace the battery cover. The remote ships with 2 batteries. One battery is needed for operation and the other battery is complimentary. Empty Battery Slot I
ページ12に含まれる内容の要旨
RMT-4IR REMOTE AND 4X1 KVM SWITCHER CONFIGURATION How to Resolve IR Code Confl icts In the event that IR commands from other remote controls confl ict with the supplied RMT-4IR remote control, changing the remote channel will alleviate this issue. The RMT-4IR remote control and the 4x1 DVI KVM DL/SL Switcher both have banks of DIP (Dual Inline Package) Switches for confi guring the remote channel that both units use to communicate. These settings must exactly match each other for proper operat
ページ13に含まれる内容の要旨
EDID MODES What is EDID and what is it used for? Under normal circumstances, an audio/video source device (digital or analog) will require information about a connected device/display to assess what resolutions and features (capabilities) are possible. The source device can then tailor its output to create resolutions and/or features that are compatible with the attached device/display. This capability information is called EDID (Extended Display Identifi cation Data). A source device can on
ページ14に含まれる内容の要旨
EDID MODES EDID Modes The diagram below illustrates the 4-position DIP switch bank (containing 4 small white toggle switches as shown). The functions of the switches are as follows: DIP SWITCH Function 1 IR Channel 2 IR Channel 3 EDID Mode 4 EDID Lock Mode 1 2 3 4 Use DIP switch 3 to set the desired EDID mode. (UP is On) How to set the two EDID Modes: 1. Local EDID Mode ON (Switch 3 = OFF, FACTORY DEFAULT SETTING) • During power-on, the connected display’s EDID is copied to all four local EDID
ページ15に含まれる内容の要旨
DL (DUAL LINK) ONLY MODES DL (Dual Link) Only Modes The 8-position DIP switch bank located on the underside of the 4x1 DVI KVM DL/ SL Switcher can be used to set each individual input to work in a Dual Link Only mode. These modes should only be enabled if issues occur when using Dual Link sources and displays in the default mode. DIP SWITCH Function DIP SWITCH Function 1 Input 1 Mode 5 N/A 2 Input 2 Mode 6 N/A 3 Input 3 Mode 7 N/A 4 Input 4 Mode 8 N/A DL (Dual Link) and SL (Single Link) Mode (
ページ16に含まれる内容の要旨
RS-232 SERIAL CONTROL What features are available via the RS-232 serial communications port? The 4x1 DVI KVM DL/SL Switcher can accept commands through the RS-232 serial communications port located on the rear panel. The current RS-232 control features are the ability to switch/route inputs to outputs without the RMT-4IR remote control. How do I use these features? These features were initially intended for utilization by custom installers in automated setups. However, these features can be
ページ17に含まれる内容の要旨
RS-232 SERIAL CONTROL COMMANDS RS-232 Features RS-232 remote functions are used to control of this product’s features. Features include input to output routing, EDID storage, EDID management, etc. Functions Syntax The syntax for each function is always the same: #Character as the start fl ag → Function name → Space ( _ ) as function name end fl ag → Parameter 1 → Space → Parameter n → Carriage Return ( \r ) → Sample: #FunctionName_param1_param2_param3_param4...\r Syntax is NOT case sensitive. ED
ページ18に含まれる内容の要旨
RS-232 SERIAL CONTROL COMMANDS #EDIDDSTOLO Function The #EDIDDSTOLO function reads the downstream EDID and stores into all lo- cal inputs. Syntax: #EDIDDSTOLO Parameters: None #EDIDDSTOBA Function The #EDIDDSTOBA function reads the downstream EDID and stores it to a specifi ed EDID bank. Syntax: #EDIDDSTOBA param1 Parameters: param1 EDID bank offset [1 - 7] #EDIDBATOLO Function The #EDIDBATOLO function reads an EDID from an EDID bank and stores it in all inputs. Syntax: #EDIDBATOLO param1 P
ページ19に含まれる内容の要旨
RS-232 SERIAL CONTROL COMMANDS #DDCTODS Function The #DDCTODS function routes the input DDC to the downstream EDID (pass- through mode). Syntax: #DDCTODS Parameters: None #DDCTOLO Function The #DDCTOLO function routes the input DDC to the local EDID. Syntax: #DDCTOLO Parameters: None #DEF Function The #DEF function set the Switcher to the factory default settings. Syntax: #DEF Parameters: None 16
ページ20に含まれる内容の要旨
RS-232 SERIAL CONTROL COMMANDS #LOEDIDTOBA Function The #LOEDIDTOBA function loads the specifi ed EDID fi le and stores it in a specifi ed EDID bank. Syntax: #LOEDIDTOBA param1 param2 param3 Parameters: param1 Echo mode [0 - 1] Value Meaning 0 Semi echo mode 1 Full echo mode param2 EDID size [1 - 2] Value Meaning 1 128 byte EDID 2 256 byte EDID param3 EDID bank offset [1 - 7] 17