ページ1に含まれる内容の要旨
Setup Guide
®
IP Link
IPL T Series
IP Link Ethernet Control Interfaces
(IPL T S Series, IPL T SFI244, IPL T CR48)
68-1377-01 Rev. E
09 10
IMPORTANT:
Refer to www.extron.com for
the complete user guide and
installation instructions
ページ2に含まれる内容の要旨
Safety Precautions Safety Instructions • English Warning Power sources • This equipment should be operated only from the power source indicated This symbol is intended to alert the user of important on the product. This equipment is intended to be used with a main power system with a operating and maintenance (servicing) instructions in grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt the literature provided with the equipment. to bypass or disabl
ページ3に含まれる内容の要旨
安全须知 • 中文 这个符号提示用户该设备用户手册中有重要的 警告 电源 • 该设备只能使用产品上标明的电源。 设备必须使用有地线 操作和维护说明。 的供电系统供电。 第三条线(地线)是安全设施,不能不用或 跳过 。 这个符号警告用户该设备机壳内有暴露的危险 拔掉电源 • 为安全地从设备拔掉电源, 请拔掉所有设备后或桌面电源 电压,有触电危险。 的电源线,或任何接到市电系统的电源线。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 注意 维护 • 所有维修必须由认证的维修人员进行。 设备内部没有用户可 阅读说明书 • 用户使用该设备前必须阅读并理解所有安全 以更换的零件。 为避免出现触电危险不要自己试图打开设备盖子 和使用说明。 维修该设备。 保存说明书 • 用户应保存安全说明书以备将来使用。 通风孔 • 有些设备机壳上有通风槽或孔, 它们是用来防止机内敏感元 件过热。 不要用任何东西挡住通风孔。 遵守警告 • 用户应遵守产品和用户指南上的所有安全和操 作说明。 锂电池 • 不正确的更换电池会有爆炸的危险。必须使用与厂家推荐的 相同或相近型号的电池。按照生产厂的建议处理废弃电池。
ページ4に含まれる内容の要旨
ページ5に含まれる内容の要旨
Contents Introduction .......................................1 About this Guide ................................1 IPL T Series Products ..........................1 IPL T S Series ...................................1 IPL T SFI244 .....................................4 IPL T CR48 .......................................4 Global Configurator ..........................5 System Requirements ....................7 Installing Global Configurator ......7 Setup ............................................
ページ6に含まれる内容の要旨
vi IPL T Series • Contents
ページ7に含まれる内容の要旨
Introduction This section gives an overview of the setup guide and describes the ® IPL T Series IP Link Ethernet Control Interfaces and the features of these products. Topics that are covered include: z z About this Guide z z IPL T Series Products z z Global Configurator About this Guide This setup guide describes the function, installation, and configuration of the IPL T Series Ethernet Control Interfaces. Within this guide, the term "IPL T controller" refers to products in the IPL T Series
ページ8に含まれる内容の要旨
IPL T S2 Features of the IPL T S2 include: zz 12 VDC, 1 A desktop power supply zz RJ-45 Ethernet receptacle zz Two (2) 9-pin D RS-232, RS-422, or RS-48 5 serial ports - or - Two (2) 3.5 millimeter captive screw RS-232 serial ports (common to the two 9-pin D serial ports) zz Six (6) Ethernet control ports IPL T S4 Features of the IPL T S4 include: zz 12 VDC, 1 A desktop power supply zz RJ-45 Ethernet receptacle zz Four (4) 9-pin D RS-232, RS-422, or RS-48 5 serial ports zz Six (6) Eth
ページ9に含まれる内容の要旨
Lighting Control Extron IPL T S4 Ethernet Control Interface with GlobalViewer software RS-232 TCP/IP Network RS-232 Extron Ethernet MLC 206 MediaLink Controller Remote User Control & Administrator Monitoring Projector Laptop DVD VCR Figure 1. Typical IPL T S Series Controller Application IPL T Series • Introduction 3 UID# 093012052 COM 1 COM 3 POWER LAN COM 2 COM 2 12V .5A MAX DISPLAY POWER VCR DVD Laptop VOLUME MAX MIN Extron MLC 206
ページ10に含まれる内容の要旨
IPL T SFI244 Features of the IPL T SFI244 include: z z 12 VDC, 1 A desktop power supply z z RJ-45 Ethernet receptacle z z Two (2) RS-232 serial ports z z Four (4) flex I/O ports z z Four (4) I/R ports z z Six (6) Ethernet control ports Motion Projector Detector RS-232 Screen Control Extron Extron IPL T RLY4 IPL T SFI244 Relay box Ethernet Control Interface Lighting System TCP/IP Network RS-232 VCR/ DVD 2 Ethernet ® GlobalViewer Extron DVD 1 A/V Resource IR Emitters Management and Remote Contro
ページ11に含まれる内容の要旨
Screen Control Projector Blinds Lift Control Projector Extron IPL T CR48 Ethernet Control TCP/IP Network Interface Lighting System ® GlobalViewer A/V Resource Management and Remote Control Application Figure 3. Typical IPL T CR48 Controller Application Global Configurator Global Configurator (GC) is a software application that gives you the ability to create a single configuration file of all the controlled devices on their audio/video (A/V) network. There are two types of devices in an A/V
ページ12に含まれる内容の要旨
Figure 4. Global Configurator Application Screen Using GC you can configure a single room controller or create a Web-based remote monitoring system for hundreds of A/V devices in multiple locations. You can configure an IPL T controller using GC without having the device physically connected to the A/V network. CAUTION: Use Global Configurator version 3.0 or later. Update all PCs and devices running earlier versions of GC. NOTE: Ethernet driver support requires Global Configurator 3.0 and
ページ13に含まれる内容の要旨
System Requirements The miminum system requirements for the PC on which you install Global Configurator include: ® ® z z Intel Pentium III, 1 GHz processor ® ® ® z z Microsoft Windows XP SP2, Windows Vista , or Windows 7 ® ® zz Microsoft Internet Explorer 6.0 with ActiveX enabled NOTE: If ActiveX is not enabled, you may get a prompt from the browser or you will see the "Please wait while the files are loading..." message in the GlobalViewer control page. zz Microsoft Windows Script 5.6 zz 51
ページ14に含まれる内容の要旨
To install Global Configurator from an Extron Software Products Disk if Autorun is not enabled on your PC: 1. Insert the Extron Software Products Disk into the disk drive of your PC. 2. From the Windows desktop, open My Computer and select the appropriate disk drive. 3. Double-click launch.exe. 4. Wait for the Extron Software Products page to load. 5. Click on the Software icon. 6. Scroll down to the Global Configurator description and click the Install link in the far right column. 7. F
ページ15に含まれる内容の要旨
Setup This section describes the hardware setup and configuration of the IPL T Series controllers. Topics that are covered include: z z Front Panel Features z z Rear Panel Features z z Resetting the Controller z z Connections and Wiring z z Configuring for Network Communication z z Configuring the IPL T Series with Global Configurator Front Panel Features IPL T S Series Power LED — A green LED a COM lights to indicate that the TX RTS R RX CTS unit is receiving power. IPL T S1 Reset button —
ページ16に含まれる内容の要旨
LINK LED — A green LED e lights to indicate that the IPL T S6 COM COM unit is connected to an 4 100 active network. R 1 3 5 LINK 5 2 4 6 ACT 6 ACT LED — A yellow LED f lights to indicate that data 1 2 3 3 is being sent or received. IPL T SFI244 IPL T SFI244 COM I/O IR 7 100 TX RX 1 3 1 3 R 1 LINK 8 2 ACT 9 2 4 2 4 1 2 3 4 5 6 Power LED — A green LED lights to indicate that the unit is a receiving power. Reset button — Recessed multiple function Reset button. See b Resetting the Contro
ページ17に含まれる内容の要旨
IPL T CR48 IPL T CR48 INPUT RELAY 5 100 1 3 1 3 5 7 R LINK 6 ACT 7 2 4 2 4 6 8 1 2 3 4 Power LED — A green LED lights to indicate that the unit is a receiving power. Reset button — Recessed multiple function Reset button. See b Resetting the Controller for more information. Input LEDs — A green LED lights to indicate that the port is active. c Relay LEDs — A green LED lights to indicate that the relay is d closed and activated. 100 LED — A green LED lights to indicate that the connectio
ページ18に含まれる内容の要旨
8 4 COM4 — 9-pin D connector for g IPL T S6 serial port 4 COM1 MAC: 00-05-A6-XX-XX-XX S/N: MAC address — The unique LAN h POWER COM2 12V COM3 COM4 COM5 COM6 hardware ID number (MAC .5A MAX address) of the unit (for TX RX TX RX TX RX TX RX example, 00-05-A6-00-00-01) 1 2 3 5 IPL T SFI244 6 4 5 IPL T SFI244 MAC: 00-05-A6-XX-XX-XX S/N: FLEX I/O IR POWER LAN 12V .5A MAX COM1 COM2 1 2 3 4 1 2 3 4 TX RX TX RX S G S G S G S G 1 2 3 Power connection — Connect the supplied 12 VDC po
ページ19に含まれる内容の要旨
Resetting the Controller There are five reset modes (numbered 1, 2, 3, 4, 5 for the sake of comparison with other Extron IPL products) available by using the Reset button ( ) on the front panel. The Reset button is recessed, so b use of a pointed stylus, ballpoint pen, or Extron Tweeker is suggested. CAUTION: Review the reset modes carefully. Use of the wrong reset mode may result in unintended loss of flash memory programming, reassignment of ports, or a unit reboot. NOTE: Reset mode 2 do
ページ20に含まれる内容の要旨
Connections and Wiring Power Connection To connect the power supply: 1. Insert the 2-pole captive screw connector into the power supply receptacle on the rear panel of the controller. Ridges Smooth SECTION A–A 3/16” (5 mm) Max. Power Supply Output Cord MAC: 00-05-A6-XX-XX-XX S/N: FLEX I/O IR POWER LAN 12V 1 2 3 4 1 2 3 4 .5A MAX COM1 COM2 TX RX TX RX S G S G S G S G Power Supply Receptacle DC Power Cord Captive Screw Connector Ground +12 VDC External Power Supply (12 VDC, 1 A ) A