ページ1に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com
TM
GE/AR80 Installation Manual
making connections in a high-speed world
Wireless Gigabit Ethernet Links
Models GE80 and AR80
Installation Manual
P/N 580-00519
Revision A
September 2006
580-00519, rev A 1 of 40
* For pricing and a quotation, visit MeridianMicrowave.com
ページ2に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
Copyright Notice & Disclaimer Copyright © 2004-2006 BridgeWave Communications. All rights reserved. Printed in the USA No portion of this publication may be reproduced, copied, or distributed without the written consent of BridgeWave Communications. BridgeWave reserves the right to update or change the material in this publication at any time without notice. BridgeWave has made every eff
ページ3に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
Product Compatibility While every effort has been made to verify operation of this product with many different communications products and networks, BridgeWave makes no claim of compatibility between its products and other vendors’ equipment. Customer is responsible for thoroughly evaluated this product’s performance in the communications environment in which it will be used. Safety CAUTI
ページ4に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
Regulatory Information This device complies with Part 101 of the FCC Rules. Links installed in the U.S. must be registered with the FCC as provided for in Part 101 of the FCC regulations. For more information contact BridgeWave’s Customer Service via E-mail support@bridgewave.com or call at 408-567-6906. Equipment Precautions Water and Moisture - The GE/AR80 is designed to withstand pre
ページ5に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
Table of Contents Section# Page # Copyright Notice & Disclaimer 2 Product Compatibility 3 Safety 3 Regulatory Information 4 Equipment Precautions 4 Table of Contents 5 1 Introduction 6 1.1 Purpose of Manual 6 1.2 Prior Knowledge and Manual Conventions 6 1.3 Contact Information & RMA 7 8 2 Site Planning 2.1 General 8 2.2 Equipment Checklist 8 2.3 Line of Sight 8 2.4 Link
ページ6に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
1 Introduction 1.1 Purpose of Manual The information in this manual is directed to persons who must perform or coordinate the tasks associated with the process of installing wireless communication devices, and planning communication network applications. 1.2 Prior Knowledge This manual assumes the operator has at least basic experience with and an understanding of wireless technology and
ページ7に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
1.3 Contact Information Technical Assistance and Customer Service BridgeWave distributors and resellers are authorized local service providers and are responsible for immediate Tier 1 customer support. If problems are not resolved, contact BridgeWave Customer Service for assistance: Location: Santa Clara, CA USA E-mail: support@bridgewave.com Tech Support Hot Line: +1.408.
ページ8に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
2 Site Planning 2.1 General Before the start of an installation a survey should be conducted of the proposed area of the deployment site(s). The survey personnel should be fully familiar with the details required to install the GE/AR80 radio system. 2.2 Equipment Checklist We suggest the site survey team may need the following equipment: • Binoculars (not always required) • GPS location
ページ9に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
2.4 Link Distance Measurement of the link distance is important in estimating the link availability and calculating expected Receive Signal Level (RSL). This measurement can be performed using the Latitude and Longitude coordinate readings from a Global Positioning System (GPS) device, which is placed near the proposed locations of the antennas. Additionally GPS reading will be required in
ページ10に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
The radio requires LC type connectors on a pair of simplex multi-mode fibers to properly connect between the radio and the users network equipment. Single-mode fiber connections are not supported for use with the standard product. The network equipment end of the fibers should be terminated with connectors that match the user’s network equipment fiber interface. Fiber Cable Length Cable
ページ11に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
Figure 2-4: 14-gauge DC power cable terminated to radio end and power supply end. Figure 2-4 (right) details a standard 14-gauge wire that has been fitted with the power connectors (provided) for the radio’s internal power supply necessary to mate with the (not provided) power cord. A standard crimping/splicing tool (not provided) is required to terminate the power connectors onto a 14-
ページ12に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
2.7 Grounding & Lightning Protection WARNING! Proper grounding of the outdoor equipment reduces electromagnetic interference, provides surge protection, and protects against electrical discharge. The source and connection points for the building-to-earth ground in the vicinity of the antenna location should be determined. It is recommended to connect the radio to the building ground by c
ページ13に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
2.8 Environmental The structure to which the equipment will be mounted should be adequate to bear all wind and weather conditions. The environmental conditions at the location must conform to the operating environment specified for the equipment. 2.9 Simple Network Diagram Following is a diagram detailing the equipment and cabling found on a typical installation of BridgeWave’s 80GHz radio
ページ14に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
3 Installation 3.1 General It is recommended that installation personnel read this section in its entirety prior to installing the BridgeWave System. During a particular phase of installation, the user may refer directly to the applicable subsection. The Installation section is comprised of seven subsections covering the procedures and guidelines for installing the BridgeWave Radio System
ページ15に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
3.3 Equipment Inventory Following are inventory lists for a typical system: Qty Description 2 ea. GE80 radio units (1 low band transmit unit & 1 high band transmit unit) 2 ea. AC-DC power adapters & power cords 1 ea. CD-ROM containing Installation Manual and NMS Manual (1 CD provided per pair of radios) 2 ea. DC power connectors for use with outdoor radio 4 ea. DC power connectors
ページ16に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
CAUTION! Tampering with seals will void the warranty. Notice the warranty stickers on the inner (metal) cover of the radio. The radio is sealed at the factory. There is no need to open this cover in the field. Tampering with these seals will void the warranty. 3.4 Installation Tools The following tools, not provided by BridgeWave, are required for installing the radio and the antenna:
ページ17に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
3.5 Antenna Mount Installation WARNING! 1. Read these instructions before beginning installation. Caution should be used. Qualified persons experienced with antenna assembly and installation are required for installation. 2. BridgeWave Communications Inc. disclaims any responsibility or liability for damage or injury resulting from incorrect or unsafe installation practices. 3. T
ページ18に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
2. Attach the lower pole mount as shown. Hardware: Flat washer, bushing (inside eye), flat washer, lock washer, bolt. Confirm that the Mount is centered as shown. Tighten bolts securely Figure 3-3 and 3-4 580-00519, rev A 18 of 40 * For pricing and a quotation, visit MeridianMicrowave.com
ページ19に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
3. Completed installation of pole mount with right hand offset for the antenna. Note the position of the elevation adjust hex nut. Figure 3-5 4. Optional left hand antenna offset mount preparation. - Remove bolts - Rotate the antenna mounting plate 180º - Replace bolts - Tighten bolts securely Note the new position of the elevation adjust hex nut. Figure 3-6 580-00519, rev
ページ20に含まれる内容の要旨
* For pricing and a quotation, visit MeridianMicrowave.com TM GE/AR80 Installation Manual
3.6 Antenna and Radio Installation 1. Install – Antenna and Radio Captive bolts Figures 3-7 and 3-8: The first letter of the designated Polarization is stamped onto each unit to identify orientations when the polarity mark is positioned on top: illustrations above are for Horizontal (left) and Vertical polarity right). CAUTION! It is critically important during install