ページ1に含まれる内容の要旨
DS Series Manual
DATA SWITCH
DS62 Host Ethernet Module
&
DS62-MD4 Host Ethernet-Modem Module
BayTech Manual Publication
Revision: May 2008
ページ2に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Copyright 2007 by Bay Technical Associates, Inc. BayTech, is a registered trademarks of Bay Technical Associates, Inc. Windows 2000®, Windows XP® are products and registered trademark of Microsoft Corporation. Tera Term is a product and registered trademark of Vector, Inc. 2
ページ3に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module ABOUT THIS OWNER’S MANUAL ........................................................................................................5 Connection Description.......................................................................................................................6 EIA-232 SERIAL CONNECTION.....................................................................................................6 Internal MODEM CONNECTION.................
ページ4に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module DS Management ...............................................................................................................................35 Internal Alarm Threshold ...............................................................................................................35 External Alarm Threshold..............................................................................................................36 Outlet Groups .............
ページ5に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module ABOUT THIS OWNER’S MANUAL This document is applicable to the DS62 Network Module and the DS62-MD4 Network/Modem Module EXCEPT those paragraphs specifically mentioning the DS62-MD4 do not apply to the DS62. This document provides information required for installing and operating your Bay Tech equipment. It should allow the user to connect to, power up, and access an applications menu where peripheral equipment can be controlled. We recommen
ページ6に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Connection Description BayTech's host communication module provides an interface that controls user access to the DS Series data switch and other DS Series connected modules. EIA-232 SERIAL CONNECTION The DS-Series host communications modules have an RJ-45 port which uses an 8-pin crossed modular cable to connect to a local EIA-232 device such as a computer terminal or external modem. Most serial computers do not have RJ-45 connections; t
ページ7に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module PREPARING THE INSTALLATION SITE The installation area should be clean and free of extreme temperatures and humidity. Allow sufficient space behind the DS unit for cabling and receptacle connections. Access to installation site should be restricted to authorized personnel. Installation of these units should be limited to ITE and Telco server environments. Power CAUTION: This unit is intended for indoor use only. Do not install near wa
ページ8に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module 5. Select ‘C’ for the configuration menu. 6. Select the HOST module. You should see a menu similar to (Figure 2). 7. Select the number for ‘Login Setup’ option. You should see a menu similar to (Figure 3). 8. Select the number for ‘Manage Users’ option. You should see a menu similar to (Figure 4). 9. NOTE: The ‘root’ user can not be deleted. 10. Select ‘A’ to add user. Type the name and password at the prompts. 11. Press ‘Enter’ until get
ページ9に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Figure 1 DS-Series - F 2.10.05 (C) 2005 Bay Technical Associates Module Name: DS62 Module: 1 Attention Character: ; Device A (2, 1).........1 Device B (2, 2).........2 Device C (2, 3).........3 Device D (2, 4).........4 DS-DS (5, 1).........5 Status..........................S Current configuration Configure.......................C Make Changes
ページ10に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Attention Character If no Baytech power strips are to be controlled through this Data Server, skip this step. Pressing the Attention Character 5 consecutive times will access the network main menu. The Default is a semi- colon (;). Select this option to change the attention character. The DS displays the following: Attention Character is........... ; Enter Attention Character : Login Setup Menu Figure 3 Access Control.........
ページ11に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Radius Configuration Radius is used to authenticate logins for the serial and the network ports if passwords and user names are enabled on the DS. If the Radius server rejects either the username or password or does not respond, the DS will display “Invalid Password”. TACACS Configuration TACACS can be used to authenticate logins for the serial port, the network port, and modem. When a telnet / SSH session (or rs232 session) is started
ページ12に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Cabling RJ-45 Cables and Adapters DS62 EIA-232 RJ-45 Signal Pin EIA 232 Signal Description Signal Direction 1 DTR Out Handshake, Line Driver Inactive State = High: +12V when power is applied. Used as a handshake line to enable/disable the receiving of characters. 2 GND Signal Ground 3 RTS Out Handshake, Line Driver Inactive State = High: +12 V when power is applied. Not used to enable/disable. 4 TX Out Transmit Data Out 5 RX In R
ページ13に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Adapters 9FRJ45PC (With Cisco Interface) 9FRJ45PC-1 (Without Cisco Interface) RJ08X007 Figures 1 and 2 provide visual representation of an RJ-45 receptacle and plug. 13
ページ14に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Detail Operations and Configurations NOTE: Depending on the DS-Series model, the menus may vary according to the number of DS74 modules installed in the unit. If this is not an initial set-up and Password has already been enabled, you are prompted to login. After logging in successfully, invoke the main menu by sending the attention character five times (;;;;;). NOTE: Password feature is case sensitive. Default is ‘root/baytech’. Main Scr
ページ15に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Accept changes ? (Y/N) :y Changes accepted. Unit Configuration Menu The configuration menu allows the admin user to establish the parameters the DS-Series will operate. Configuration DS62 module #1..........1 DS74 module #2..........2 DS-RPC module #5..........3 Enter Request : Select the number of the host module and the following menu is displayed: Copyright(C) Bay Technical Associat
ページ16に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Installed Modules :01,02,05 Attention Character is ......... ; Disconnect Time Guard is........ Disabled Port ID Echo is................. Disabled Module Name is.................. DS62 Network Connectivity & Login Configuration: Ethernet Address................ 00:C0:48:00:01:FD IP Address...................... 0.0.0.0 Subnet Mask..................... 0.0.0.0 Default Gateway................. 0.0.0.0 Inactivity Tim
ページ17に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Serial Port Configuration Handshaking, Baud Rate, Word Size, Stop Bits, and Parity are configured through either the serial or Ethernet ports using the menus. RTS and DTR Line Drivers can only be configured through the phone line via a modem. The default settings are 9600bps, 8 data bits, no parity, one stop bit, RTS and DTR High. IMPORTANT: Changing the Host module serial port configuration could create a communications lock-out if the
ページ18に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module via binary, it is very likely that these values could be transmitted as data and the transmission would fail. 2. Hardware Handshaking: This style uses actual hardware lines. Like the TX and Rx lines, the RTS/CTS and DTR/DSR lines work together. When a receiver is ready for data, it will assert the RTS (Request to Send) line. This is then read by the sender at the CTS (Clear to Send) input, indicating it is clear to send the data. DTR (Dat
ページ19に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module Stop Bits The Stop Bits are used to signal the end of communication for a single packet. Since the data is clocked across the lines and each device has its own clock, it is possible for the two devices to become slightly out of sync. Therefore, the stop bits not only indicate the end of transmission but also give the computers some room for error in the clock speeds. The more bits that are used for stop bits, the greater the lenience in sync
ページ20に含まれる内容の要旨
DS62-Network, DS62-MD4 Network/Modem Host Module DTR Line Driver Inactive State is: High High ? (Y/N, CR for no change): Serial Port Device Name Select a port and type the new name. Current device name: EIA-RS232 Enter device name for serial port ((1 - 16 char., CR to end) : Attention Character Pressing the Attention Character 5 consecutive times will access the network main menu. The Default is a semi-colon (;). Select this option to change the attention character. The DS display