ページ1に含まれる内容の要旨
x600 Series
Layer 3 Gigabit
Ethernet Switches
x600-24Ts
x600-24Ts/XP
x600-48Ts
x600-48Ts/XP
x600-24Ts-POE
x600-24Ts-POE+
Installation Guide
613-001394 Rev. A
ページ2に含まれる内容の要旨
Copyright © 2010 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
ページ3に含まれる内容の要旨
Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy a
ページ4に含まれる内容の要旨
Translated Safety Statements Important: The symbol indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements”. This is posted on the Allied Telesis website at http:/ /www.alliedtelesis.com/support/software/. Refer to “Where to Find Web-based Guides” on page 15 to navigate to this document. 4
ページ5に含まれる内容の要旨
Contents Preface ............................................................................................................................................................ 11 Product Documentation.............................................................................................................................. 12 Starting a Management Session................................................................................................................ 13 Safety Symbols Used in this
ページ6に含まれる内容の要旨
Contents VCS Stacking Module.................................................................................................................................48 AC Power Connector..................................................................................................................................49 Chapter 2: Virtual Chassis Stacking ...............................................................................................................51 TM VCStack Introduction................
ページ7に含まれる内容の要旨
List of Figures Figure 1. x600-24Ts Switch.................................................................................................................................................19 Figure 2. x600-24Ts/XP Switch ...........................................................................................................................................20 Figure 3. x600-48Ts Switch.............................................................................................................
ページ8に含まれる内容の要旨
Figures 8
ページ9に含まれる内容の要旨
List of Tables Table 1. Safety Symbols .....................................................................................................................................................14 Table 2. 10/100/1000Base-T Ports Matched with SFP Slots ..............................................................................................29 Table 3. Base-T LED Descriptions ........................................................................................................................
ページ10に含まれる内容の要旨
Tables 10
ページ11に含まれる内容の要旨
Preface This guide contains the installation instructions for the x600 Series Layer 3 Gigabit Ethernet Switches. This preface contains the following sections: “Product Documentation” on page 12 “Starting a Management Session” on page 13 “Safety Symbols Used in this Document” on page 14 “Where to Find Web-based Guides” on page 15 “Contacting Allied Telesis” on page 16 11
ページ12に含まれる内容の要旨
Preface Product Documentation For overview information about the software features of the AlliedWare Plus Operating System Software which runs on the x600 Series Switches, refer to: AlliedWare Plus Operating System Software Reference Guide Virtual Chassis Stacking (VCS) How To Note AT-StackXG Stacking Module Installation Guide 12
ページ13に含まれる内容の要旨
x600 Layer 3 Gigabit Ethernet Switch Installation Guide Starting a Management Session For instructions that describe how to start a local management session on an x600 switch, refer to the “Starting a Local Management Session” on TM page 89. For information that describes how to log onto the AlliedPlus Operating System Software, see the AlliedWare Plus Operating System Software Reference Guide. 13
ページ14に含まれる内容の要旨
Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific action may result in electrical shock. 14
ページ15に含まれる内容の要旨
x600 Layer 3 Gigabit Ethernet Switch Installation Guide Where to Find Web-based Guides The product documentation for all Allied Telesis products are available in portable document format (PDF) on our web site. Go to http://www.alliedtelesis.com/support/software/. Enter your hardware product model in the Search by Product Name field; for example, enter AT-x600-24Ts-POE. You can view the documents online or download them onto your local workstation or server. 15
ページ16に含まれる内容の要旨
Preface Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales and corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com/support/kb.aspx. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions. Email and For Technical Support via email or telephone, refer t
ページ17に含まれる内容の要旨
Chapter 1 Overview This chapter contains the following sections: “Introduction” on page 18 “Switch Descriptions” on page 19 “10/100/1000Base-T Ports” on page 25 “SFP Transceiver Slots” on page 27 “XFP Transceiver Slots” on page 28 “Combo Ports” on page 29 “SD Card Slot” on page 30 “Port LEDs” on page 31 “System STATUS LEDs” on page 36 “STACK LEDs” on page 37 “Secure Digital (SD) LED” on page 39 “Terminal Port” on page 40 “Power Over Ethernet (PoE and PoE+)” on page 41 “Redundant
ページ18に含まれる内容の要旨
Chapter 1: Overview Introduction The x600 Series Switches are managed Gigabit Ethernet switches that act as standalone units. There are six Basic Layer 3 switches in the series: x600-24Ts Switch x600-24Ts/XP Switch x600-48Ts Switch x600-48Ts/XP Switch x600-24Ts-POE Switch x600-24Ts-POE+ Switch The AlliedWare Plus Operating System Software (AW+) runs on all the x600 switches. The x600-24Ts-POE requires AW+ software version 5.3.3 or later. The x600-24Ts-POE+ requires AW+ software versio
ページ19に含まれる内容の要旨
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide Switch Descriptions The following sections describe the x600 Series Layer 3 Gigabit Ethernet Switches. x600-24Ts Switch The x600-24Ts switch has the following hardware features: 24 10/100/1000Base-T ports Four Gigabit Ethernet small form-factor pluggable (SFP) transceiver slots An RJ-45 style serial terminal port for local (out-of-band) management One SD slot supporting up to 4GB SD cards Status LEDs for the ports, transceiv
ページ20に含まれる内容の要旨
Chapter 1: Overview x600-24Ts/XP The x600-24Ts/XP switch has the following hardware features: Switch 24 10/100/1000Base-T ports Four Gigabit Ethernet small form-factor pluggable (SFP) transceiver slots Two 10 Gigabit Ethernet small form factor pluggable (XFP) transceiver slots An RJ-45 style serial terminal port for local (out-of-band) management One SD slot supporting up to 4GB SD cards Status LEDs for the ports, transceiver slots, and system Redundant power supply connector Expansion