ページ1に含まれる内容の要旨
EKI-7758F
8G ports Industrial Managed
Redundant Gigabit Ethernet
Switch, 4 Gigabit Copper
and 4 Gigabit SFP
User Manual
ページ2に含まれる内容の要旨
Copyright The documentation and the software included with this product are copyrighted 2007 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accu
ページ3に含まれる内容の要旨
Product Warranty (2 years) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability under the terms of this warranty a
ページ4に含まれる内容の要旨
Declaration of Conformity CE This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device
ページ5に含まれる内容の要旨
Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation. Dropping it or let
ページ6に含まれる内容の要旨
Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage. 1. To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards while the PC is on. 2. Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components. EKI-77
ページ7に含まれる内容の要旨
Contents Chapter 1 Overview ........................................... 2 1.1 Introduction .......................................... 2 1.1.1 The SFP Advantage ...................... 2 1.1.2 High-Speed Transmissions ........... 2 1.1.3 Dual Power Input ........................... 2 1.1.4 Flexible Mounting .......................... 2 1.1.5 Advanced Protection ..................... 3 1.1.6 Wide Operating Temperature ........ 3 1.1.7 Easy Troubleshooting.................... 3 1.2 Feature
ページ8に含まれる内容の要旨
3.1.1 Commands Level ........................ 26 Table 3.1: Command Level ......................................... 26 3.1.2 Commands Set List ..................... 27 Table 3.2: Commands Set List .................................... 27 3.1.3 System Commands Set ............... 27 Table 3.3: System Commands Set ............................... 27 3.1.4 Port Commands Set .................... 28 Table 3.4: Port Commands Set ................................... 28 3.1.5 Trunk Commands Set ..
ページ9に含まれる内容の要旨
Figure 3.16: Syslog Configuration .............................. 46 Figure 3.17: SMTP Configuration ............................... 47 Figure 3.18: Event Configuration ................................ 48 Figure 3.19: Fault Relay Alarm ................................... 49 Table 3.18: UTC Timezone ......................................... 49 Figure 3.20: SNTP Configuration ............................... 51 Figure 3.21: IP Security ............................................... 52 Figure
ページ10に含まれる内容の要旨
Figure A.4: DB 9-pin female connector ...................... 87 Appendix B Compatible SFP Modules ........... 90 Appendix C X-View ........................................... 92 Figure C.1: X-View interface ...................................... 92 Figure C.2: Items to the ‘Task’ menu bar .................... 92 Figure C.3: Two devices have been discovered .......... 93 Figure C.4: Discovery Filter setting window .............. 93 Figure C.5: Login interface ........................
ページ11に含まれる内容の要旨
Figure C.33: Port Control .......................................... 111 C.2.3 Port Status ................................ 111 Figure C.34: Port Status ............................................. 111 C.2.4 Port Trunk ................................. 112 Figure C.35: Port Trunk ............................................. 112 Figure C.36: Port Trunk Status .................................. 113 C.2.5 Port Mirroring ............................ 113 Figure C.37: Port Mirroring .........
ページ12に含まれる内容の要旨
C.6 Save To Flash ................................. 134 Figure C.67: Save to Flash ........................................ 134 C.7 System Reboot ................................ 135 Figure C.68: System Reboot ...................................... 135 EKI-7758F User Manual xii
ページ13に含まれる内容の要旨
xiii Contents
ページ14に含まれる内容の要旨
ページ15に含まれる内容の要旨
Overview Sections include: Introduction Features Specifications Packing List Safety Precaution 1 Chapter1 CHAPTER
ページ16に含まれる内容の要旨
Chapter 1 Overview 1.1 Introduction To create reliability in your network, the EKI-7758F comes equipped with a proprietary redundant network protocol—X-Ring that was developed by Advantech, which provides users with an easy way to establish a redundant Ethernet network with ultra high-speed recovery time less than 10 ms. Aside from 4 x 10/100/1000Base-T(X) fast Ethernet ports, the EKI-7758F come equipped with 4 SFP (mini-GBIC) fiber optic ports. Traditional RJ-45 ports can be us
ページ17に含まれる内容の要旨
1.1.5 Advanced Protection The power line of EKI-7758F supports up to 3,000 V EFT protection, which secure DC equipment against unregulated voltage and make systems safer and more reliable. Meanwhile, 4,000 V ESD protections for Ethernet ports make EKI-7758F more DC suitable for harsh environments. 1.1.6 Wide Operating Temperature The operating temperature of the EKI-7758F is between -10 ~ 60 ℃. With such a wide range, you can use the EKI-7758F in some of the harshest industrial
ページ18に含まれる内容の要旨
1.2 Features • All Gigabit Ethernet ports for 4 Copper and 4 SFP • SFP sockets for easy and flexible fiber expansion • Redundancy: Gigabit X-Ring (ultra high-speed recovery time < 10ms), RSTP/STP (802.1w/1D) • Management: Web, Telnet, Serial Console, Windows Utility, SNMP • Control: VLAN/GVRP, QoS, IGMP Snooping, LACP, Rate Limit • Security: IP/MAC and port binding, DHCP Server, IP access list, 802.1x, SNMPv3 • Diagnostic: Port statistic, Port Mirroring, RMON, Trap, SMTP Alert,
ページ19に含まれる内容の要旨
1.3 Specification Communications IEEE 802.3, 802.3ab, 802.3ad, 802.3u, 802.3x, Standard 802.3z IEEE 802.1d, 802.1p, 802.1Q, 802.1w, 802.1X, 10/100/1000Base-TX, Optional 100Base-FX, LAN 1000Base-SX/LX/LHX/XD/ZX/EZX Ethernet: Up to 100m (4-wire Cat.5e, Cat.6 RJ-45 Transmission Distance cable suggested for Gigabit port) SFP: Up to 110km (depends on SFP) Gigabit Copper: 10/100/1000 Mbps, Auto-Negotiation Transmission Speed Gigabit Fiber: Up to 1000Mbps Int
ページ20に含まれる内容の要旨
Power Consumption Max. 17 W 2 x Unregulated +12 ~ 48 V Power Input DC 1 Relay Output Fault Output Mechanism 79 x 152 x 105 mm Dimensions (WxHxD) IP30, metal shell with solid mounting kits Enclosure DIN-rail, wall Mounting Protection ESD (Ethernet) 4,000 V DC 3,000 V Surge (EFT for power) DC Present Power Reverse 3.2A / 60V Replaceable Fuse Overload Environment -10 ~ 60 ℃ (14 ~ 140 ℉) Operating Temperature 5 ~ 95% (non-condensing) Operating