® OMEGAnet Online Service Internet e-mail www.omega.com info@omega.com Servicing North America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certifi ed Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Berg
ページ3に含まれる内容の要旨
OMEGA FP-5060 Series Micro-Flow Sensors SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi cations. 3. Do not install/service without following installation instructions (see sensor manual). 4. Wear safety goggles and faceshield during installation/service. 5. Do not alter product construction. 6. Failure to follow safety instructions could result in severe personal injury! 1. Instrument Wiring OMEGA FP-90 Series, FPM-5500, FPM-9020A
ページ4に含まれる内容の要旨
3. Surface Mount Instructions Remove sensor then use correct 2 screws for panel material. #6 or M3 metric screws recommended 120° 1 Mounting surface (top), Mounting surface (side) Mounting surface 68 mm (2.68 in.) bolt circle 4. Fitting Installation CAUTION: • Maximum pipe fi tting torque: 10 ft - lbs (13 N m). • DO NOT overtighten. Failure to observe torque specifi cation may permanently damage sensor ports. FP-5060 Pipe Pipe fitting Pipe fitting Pipe Sealant Technical Notes: • Compatible
ページ5に含まれる内容の要旨
6. Specifi cations General Electrical Flow range: Supply voltage: 5 to 24 VDC, regulated 5061 and 5062: 0.11 to 2.6 lpm (0.03 to 0.7 gpm) Supply current: 10 mA max. 5063 and 5064: 1.13 to 12.11 lpm (0.3 to 3.2 gpm) Output type: Open-collector NPN transistor, 10 mA max sink Linearity: ±1.2% of full range Repeatability: ±0.5% of full range Connections: ¼ in. NPT (male) or ISO 7/1 - R¼ (male) Quality Standard Cable length: 8 m (25 ft.), can splice up to 300 m (1000 ft.) max. • Manufactured u
ページ6に含まれる内容の要旨
NOTES: page 6 OMEGA FP-5060 Series Micro Flow Sensor
ページ7に含まれる内容の要旨
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Departme
ページ8に含まれる内容の要旨
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www.omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessori