ページ1に含まれる内容の要旨
Intelligent Flag I/II
V600-HA
Innovative RFID Electronic Flags to
Replace Mechanical Flag and Kanban
Systems
• Doesn't need a program and can be used like a sensor.
Advanced line construction at minimal cost.
Saves space.
Precise installation not required (Transmission distance:
100 mm max.).
A verification function provided on multi-functional type.
Addition of 16-bit models to the series responds to applica-
tions from Kanban to quality control.
Equipped with a wiring reduction
ページ2に含まれる内容の要旨
Type Read-only (8-bit) Multi-functional (8-bit) Read-only (16-bit) Item Model V600-HAR91 V600-HAR81 V600-HAM91 V600-HAM81 V600-HAR92 Vibration resistance Destruction: 10 to 150 Hz, 0.3-mm double amplitude, with 4 sweeps of 8 min each in Destruction: 10 to 150 Hz, 1.5-mm 3 directions double amplitude, with 4 sweeps of 8 min each in 3 directions 2 Shock resistance Destruction: 294 m/s , 3 times each in 6 directions Ambient temperature −10 to 55 °C (with no icing) Ambient humidity 35%
ページ3に含まれる内容の要旨
■ Sensor Model V600-HS51 V600-HS61 V600-HS63 V600-HS67 Shape Item Transmission frequency 530 kHz Ambient temperature −10 to 60 °C −10 to 70 °C Storage temperature −25 to 75 °C Ambient humidity 35% to 95% Insulation resistance 50 M Ω (at 500 VDC) between cable terminal and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between cable terminal and case (leakage current: 1 mA max.) Degree of protection IEC60529: IP67 Vibration resistance Destruction: 10 to 2,000 Hz, 3-mm double amplitude, wi
ページ4に含まれる内容の要旨
System Configuration Host Sensor (Cable length: fixed to 2 m) Programmable Controller, I/O terminal, B7A, CompoBus/S, etc. Sensor Controller Terminal block wiring Connector Interface cable connection V600-A6 R V600-A6 M Amplifier (Cable length: Connector pins: 20 Connector pins: 26 fixed to 0.5 m, with connector) Cable lengths: 2 m, 5 m, Cable lengths: 2 m, 5 m, interface 10 m 10 m Connector Connector Connector connection connection connection Amplifier Power V600 Power V600 Power V600 su
ページ5に含まれる内容の要旨
Characteristic Data (Typical) ■ Transmission Range Combinations with the V600-HS51 Sensor V600-HS51 & V600-D23P53 V600-HS51 & V600-D23P54 V600-HS51 & V600-D23P55 Y Y Y Y Y Y 15 X 12 X X 8 10 8 4 5 4 –15 –10 –5 0 5 10 15 X –8 –4 0 4 8 X –12 –8 –4 0 4 812 X V600-HS51 & V600-D23P61 V600-HS51 & V600-D23P66N V600-HS51 & V600-D8KR12 Y Y Y Y Y Y 30 15 30 X X X 20 10 20 10 5 10 –15 –10 –5 0 5 10 15 X –30 –20 –10 0 10 20 30 X –30 –20 –10 0 10 20 30 X Combinations with the V600-HS61 Sensor V600-HS61 & V60
ページ6に含まれる内容の要旨
Combinations with the V600-HS63 Sensor V600-HS63 & V600-D23P55 V600-HS63 & V600-D23P61 V600-HS63 & V600-D23P66N Y Y Y Y Y 50 Y 30 40 30 X X X 30 20 20 20 10 10 10 –40 –30 –20 –10 0 10 20 30 40 X –50 –40 –30 –20 –10 0 10 20 30 40 50 X –30 –20 –10 0 10 20 30 X V600-HS63 & V600-D23P66SP V600-HS63 & V600-D23P71 V600-HS63 & V600-D23P72 Y Y Y Y Y Y 50 60 40 60 X X X X 30 40 40 20 20 20 10 –50 –40 –30 –20 –10 0 10 20 30 40 50 X –60 –40 –20 0 20 40 60 X –60 –40 –20 0 20 40 60 X V600-HS63 & V600-D8KR12 V
ページ7に含まれる内容の要旨
Combinations with the V600-HS67 Sensor V600-HS67 & V600-D23P66N V600-HS67 & V600-D23P66SP V600-HS67 & V600-D23P71 Y Y Y Y Y Y 80 80 100 80 60 60 X X X X 60 40 40 40 20 20 20 –80 –60 –40 –20 020 40 60 80 X –80 –60 –40 –20 0 20 40 60 80 X –100 –80 –60 –40 –20 0 20 40 60 80 100 X V600-HS67 & V600-D23P72 V600-HS67 & V600-D8KR12 V600-HS67 & V600-D8KR13 Y Y Y Y Y Y 80 100 80 X 80 X 60 60 X 60 40 40 40 20 20 20 –80 –60 –40 –20 0 20406080 X –80 –60 –40 –20 0 20406080 X –100 –80 –60 –40 –20 0 20 40 60 80
ページ8に含まれる内容の要旨
Circuit Configuration V600-HAR91 V600-HAR81 V600-HAM91 V600-HAM81 Input Circuit Input Circuit +DC 24 V Tr IN 8.2 k Ω ON/ Main circuit IN Main circuit OFF 8.2 k Ω Tr 0 V 0 V Output Circuit Output Circuit +DC OUT Main circuit Main circuit OUT 0 V 0 V V600-HAR92 Input Circuit 24 V 8.2 k Ω ON/ Main circuit IN OFF Tr 0 V Output Circuit OUT Main circuit 0 V Precautions The following OMRON products cannot be connected to this product. ■ Cautions CVM1-OD219, C20H, C28H, C40H, or C60H Programmable Cont
ページ9に含まれる内容の要旨
Power Supply Voltage I/O Interface Requirements Do not impose any voltage exceeding the rated voltage range. Doing 1. The TRG input must be 10 ms min. so, or applying alternating current (100 VAC) may cause the product 2. The INHIBIT input must be 20 ms min. to explode or burn. 3. Minimum of 5 ms is required as the transfer time of the Read/ Write Selection Input (W/R). Load Short-circuiting 4. The read data output must be read after the Normal End Output is set to ON. Do not short-circuit the l
ページ10に含まれる内容の要旨
Dimensions Note: All units are in millimeters unless otherwise indicated. Amplifier V600-HAR91/-HAR81 25 * Enlarged Section of Mounting Hole 4.4 30 Mounting Hole Dimensions 5.5 30 55 Two, mounting 30û holes * 21 6 2-M4 17.5 28.3 36.3 61.8 68.5 89±0.2 80 35.2 98 89 ± 21 0.2 Vinyl-insulated round cord 5.8-mm dia., 13-conductor cable, standard length: 0.5 m 500 mm 28.1 XG4E-2031 44.7 8.2 25 Intelligent Flag I/II V600-HA 11
ページ11に含まれる内容の要旨
V600-HAM91/-HAM81 25 * Enlarged Section of Mounting Hole 4.4 30 Mounting Hole Dimensions 5.5 30 55 Two mounting 30˚ 6 21 holes * 2-M4 17.5 28.3 36.3 44.3 52.3 61.8 68.5 ± 89 0.2 75 80 89 35.2 98 21±0.2 Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m 500 mm 28.1 XG4E-2631 52.3 8.2 25 12 Intelligent Flag I/II V600-HA
ページ12に含まれる内容の要旨
V600-HAR92 25 * Enlarged Section of Mounting Hole 4.4 30 Mounting Hole Dimensions 5.5 30 55 Two, mounting 30˚ 6 21 holes * 2-M4 17.5 28.3 36.3 44.3 61.8 68.5 ± 75 89 0.2 80 89 35.2 98 21±0.2 Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m 500 mm 28.1 XG4E-2631 52.3 8.2 25 Sensor V600-HS51 2 lock washers Vinyl-insulated round cord (4-mm dia.) 2 lock nuts M12X1 Connector Case: Brass Transmission window: ABS resin 13.7 dia. 9.6 dia. Filter: Epoxy resin Cable: PV
ページ13に含まれる内容の要旨
V600-HS63 Two, 4.5-dia. mounting holes 2-R5 4-R1 Vinyl-insulated round cord 6-mm dia Connector (7/0.18-mm dia.), 8-conductor cable, Bushing 10 standard length: 2 m 40 28 13.8 dia. 51.5 5 27 6 5 13 5 53 20 18 Power indicator (green) 23 11 Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) V600-HS67 Four, 4.5-dia. 100 mounting holes ±0.2 5 90 5 50 50 Connector Power indicator 25 (green) 100 13.8 dia. ±0.2 90 51.5 Bushing Vinyl-insulated round cord (6-mm dia.) 10 Case: ABS resin Fil
ページ14に含まれる内容の要旨
V600-A6@M (for V600-HAM91/-HAM81/-HAR92) 10.6 +5 +100 330 L 30 7.6 0 0 20±5 20±5 20±5 30±5 37.6 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 23-conductor cable, standard length: 2 m XG5M-2632-N Connector Model L (m) V600-A60R/60M 2 V600-A61R/61M 5 V600-A62R/62M 10 Intelligent Flag I/II V600-HA 15
ページ15に含まれる内容の要旨
Terms and Conditions of all possible uses of this product, nor is it intended to imply that the WARRANTY, LIMITATIONS OF uses listed may be suitable for this product: LIABILITY Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this WARRANTY OMRON’s exclusive warranty is that the products are catalog. free from defects in materials and workmanship for a period of one Nuclear energy control systems, combustion syste