M MAXX AXX-LIN -LINK M K MLX- LX-100 100 UNI UNIVER VERSAL SAL AM AMPLIF PLIFIER IER BR BRIDG IDGING ING & S & SYNC YNCHRO HRONIZA NIZATIO TION M N MODU ODULE LE The MLX-100 Maxx-Link is a unique problem solving signal processor. The Maxx-Link The MLX-100 Maxx-Link is a unique problem solving signal processor. The Maxx-Link allows interconnecting (a.k.a. Linking) of up to five amplifier pairs in Master/Slave
ページ3に含まれる内容の要旨
MAXX-LINK MLX-100 BRIDGING MODULE FEATURE DESCRIPTIONS END PANEL CONNECTIONS MASTER OUT / SLAVE IN: The Master Out sends master signal to another MLX-100. The Slave In receives a Master signal and all controls are bypassed on the unit. BR-1 REMOTE CONTROL: Using an Rj45 cable, the BR-1 Bass Remote Module plugs directly into the MLX-100 and allows you to adjust the Level from -20dB to 0 dB as well as Normal and Bypass operations. NORMAL: BR-1 is fully adjustable from -20dB to 0dB. BYBASS:
ページ4に含まれる内容の要旨
2 MAXX-LINK MLX-100 BRIDGING MODULE 5V ON SLAVE 3V 7V OFF MASTER 35Hz 250Hz 1V 9V 15Hz 35Hz RED - CLIP TEST TONE MODE LOW PASS OUTPUT SUBSONIC 65Hz FILTER GREEN - 9V LEVEL FILTER 24 dB/OCT 24 dB/OCT MAXX-LINK MLX-100 9V 0.2V 0 180 0dB +10 dB 30Hz 100Hz INPUT PHASE BOOST BANDWIDTH FREQUENCY LEVEL PARAMETRIC BASS EQ BRIDGING OUTPUTS BR-1 REMOTE A B C D E MASTER OUT LEFT CONTROL INPUT + + + + + INPUT GND REM +12V SLAVE IN RIGHT - - - - - FULL RANGE CHASSIS GROUND BR-1 Remote Module -6dB NORMAL OPER
ページ5に含まれる内容の要旨
BR-1 REMOTE BR-1 REMOTE MASTER OUT MASTER OUT CONTROL LEFT CONTROL LEFT INPUT INPUT INPUT INPUT SLAVE IN SLAVE IN RIGHT RIGHT FULL RANGE FULL RANGE MAXX-LINK MLX-100 BRIDGING MODULE APPLICATIONS Linking 2 MLX-100s using Master/Slave operations This application illustrates the method of linking 2 MLX-100’s using the Master/Slave features. 1. Connect the full range RCA outputs from the headunit to the MLX-100 #1’s inputs. 2. Connect a single RCA from MLX-100 #1’s MASTER OUT to MLX-100 #2’s SLAVE I
ページ6に含まれる内容の要旨
4 MAXX-LINK MLX-100 BRIDGING MODULE APPLICATIONS Mono bridging 2 standard mono amplifiers with no Master/Slave feature to a single subwoofer This application illustrates the method of linking 2 Mono amplifiers to a single subwoofer. 1. Connect the full range RCA outputs from the headunit to the MLX-100 inputs. 2. Connect the RCA’s from the MLX-100 (A+ and A-) BRIDGING OUTPUTS to the amplifier INPUTS as shown. 3. The amplifier settings need to be adjusted as follows: - The LOW PASS FILTER sho
ページ7に含まれる内容の要旨
L L R R BR-1 REMOTE MASTER OUT LEFT CONTROL INPUT INPUT SLAVE IN RIGHT FULL RANGE 5 MAXX-LINK MLX-100 BRIDGING MODULE APPLICATIONS Mono bridging 2 standard mono amplifiers with no Master/Slave feature to a single subwoofer Mono Block Amplifiers INPUT -6dB BYPASS Speaker Terminals RED - CLIP -20dB 0dB GREEN - 9V NORMAL LEVEL #1 5V ON SLAVE 3V 7V MASTER OFF 35Hz 250Hz 1V 9V 15Hz 35Hz MODE LOW PASS RED - CLIP OUTPUT TEST TONE SUBSONIC FILTER GREEN - 9V LEVEL 65Hz FILTER 24 dB/OCT 24 dB/OCT MAXX-LIN
ページ8に含まれる内容の要旨
6 MAXX-LINK MLX-100BRIDGING MODULE APPLICATIONS Mono bridging 4 standard amplifiers with no Master/Slave feature to 2 subwoofers This application illustrates the method of linking 4 Mono amplifiers to 2 subwoofers. 1. Connect the full range RCA outputs from the headunit to the MLX-100 inputs. 2. Connect the RCA’s from the MLX-100 (A+ and A-) BRIDGING OUTPUTS to amplifiers 3 & 4 INPUTS as shown. Repeat this process for amplifiers 1 & 2 through B+ and -. 3. The amplifier settings need to be adjus
ページ9に含まれる内容の要旨
- - - + - + + + L L L L R R R R BR-1 REMOTE MASTER OUT LEFT CONTROL INPUT INPUT SLAVE IN RIGHT FULL RANGE 7 MAXX-LINK MLX-100 BRIDGING MODULE APPLICATIONS Mono Block Amplifiers Mono bridging 4 standard amplifiers with no INPUT Master/Slave feature to 2 subwoofers Speaker Terminals #1 -6dB BYPASS #1 RED - CLIP -20dB 0dB GREEN - 9V INPUT NORMAL LEVEL 12ga. #2 5V ON SLAVE Wire link 3V 7V OFF MASTER 35Hz 250Hz 1V 9V 15Hz 35Hz MODE LOW PASS RED - CLIP OUTPUT TEST TONE SUBSONIC FILTER GREEN
ページ10に含まれる内容の要旨
TROUBLESHOOTING A SYSTEM The key to finding the problem in a troubled sound system is to isolate parts of that system in a logical fashion to track down the fault. The key to finding the problem in a troubled sound system is to isolate parts of that system in a logical fashion to track down the fault. Description of the Diagnostic system built into the MLX-100 Maxx-Link Bridging Module: Description of the Diagnostic system built into the MLX-100 Maxx-Link Bridging Module: 1. Clipping Indicator:
ページ11に含まれる内容の要旨
MAXX-LINK MLX-100 Maxxsonics Limited Warranty As the manufacturer of Maxxsonics, Crunch, MB Quart and Hifonics car audio products, Maxxsonics USA Inc. Warrants to the original consumer purchaser the amplifier to be free from defects in material and workmanship for one (1) Year from date of purchase. All other parts and accessories of the system are warrantied to be free from defects in material and workmanship for one (1) year from date of purchase. Maxxsonics will repair or replace at i