COPYRIGHT NOTICE: © 2009, CyberData Corporation, ALL RIGHTS RESERVED. This manual and related materials are the copyrighted property of CyberData Corporation. No part of this manual or related materials may be reproduced or transmitted, in any form or by any means (except for internal use by licensed customers), without prior express written permission of CyberData Corporation. This manual, and the products, software, firmware, and/or hardware described in this manual are the property of Cy
ページ3に含まれる内容の要旨
How-To-Guide Configure the Mitel 3300 ICP for use with the Cyberdata VOIP Indoor Paging Speaker Document #09-5159-00034 Page 1
ページ4に含まれる内容の要旨
About this document This How-To-Guide is intended for Customer Service and Installation Personnel involved in the installation and maintenance of Mitel 3300 ICPs. NOTICE The information cained in this document is believed to be accurate in all respects but is not warranted by Mitel Networks Corporation. The information is subjected to change without notice and should not be construed in any way as a commitment by Mitel or any of its affiliates or subsidiaries. Mitel and its affiliat
ページ5に含まれる内容の要旨
Table of Cents Overview.............................................................................................................................................4 Software & Hardware Setup.......................................................................................................4 Device Limitations..........................................................................................................................4 3300 Setup Notes....................................
ページ6に含まれる内容の要旨
Overview This document provides a reference to Mitel Authorized Solutions providers for configuring the Mitel 3300 ICP to host the Cyberdata VOIP Indoor Paging Speaker SIP device. The different devices can be configured in various configurations depending on your VoIP solution. This document covers a basic setup with required option setup. Software & Hardware Setup This was the test setup to generate a basic SIP call between the Cyberdata VOIP Indoor Paging Speaker SIP device and the
ページ7に含まれる内容の要旨
3300 Setup Notes The following steps show how to program a 3300 ICP to connect with the Cyberdata VOIP Indoor Paging Speaker SIP device. Network Requirements • There must be adequate bandwidth to support the voice over IP. As a guide, the Ethernet bandwidth is approx 85 Kb/s per G.711 voice session and 29 Kb/s per G.729 voice session (assumes 20ms packetization). As an example, for 20 simultaneous SIP sessions, the Ethernet bandwidth consumption will be approx 1.7 Mb/s for G.711 and 0
ページ8に含まれる内容の要旨
Licensing and Option Selection - SIP Licensing Ensure that the 3300 ICP is equipped with enough SIP Device licences for the connection of SIP end points. This can be verified within the License and Option Selection form. Figure 1 – License and Option Selection Document #09-5159-00034 Page 6
ページ9に含まれる内容の要旨
Multiline IP Set Configuration On the Mitel 3300 ICP, a SIP device can be programmed either in the User Configuration form or the Multiline IP Set Configuration form and are programmed as a “Generic SIP Phone”. Enterprise Manager can also be used to provision where this application is installed. The Login PIN is the SIP authentication password and the username is the DN. The Number and Login PIN must match the information in the Cyberdata VOIP Indoor Paging Speaker SIP device configurat
ページ10に含まれる内容の要旨
Class of Service Assignment The Class of Service Options Assignment form is used to create or edit a Class of Service and specify its options. Classes of Service, identified by Class of Service numbers, are referenced by the Station Service Assignment form for the SIP devices. Ensure Public Access via DPNSS is enabled. Figure 3 – Class of Service Assignment Document #09-5159-00034 Page 8
ページ11に含まれる内容の要旨
Figure 4 – Class of Service Assignment (C) Document #09-5159-00034 Page 9
ページ12に含まれる内容の要旨
SIP Device Capabilities Assignment This form provides configuration options that can be applied to various types of SIP devices. The association between the SIP device and the form is similar to how the Class of Service options work. The SIP Device Capabilities number provides a SIP profile that can be applied to particular SIP devices to allow for alternate capabilities as recommended through the Mitel interop process. The Cyberdata VOIP Indoor Paging Speaker SIP device can only be ass
ページ13に含まれる内容の要旨
Station Service Assignment Use the Station Service Assignment form to assign the previously configured Class of Service and SIP Device Capability number to each of the Cyberdata VOIP Indoor Paging Speaker SIP devices in the 3300. This form utilizes Range programming. Select the Cyberdata VOIP Indoor Paging Speakers’ number then select Change. Enter the previously configured SIP Device Capability number and Class of Service for Day, Night 1 & Night 2. Figure 6 – Station Servic
ページ14に含まれる内容の要旨
Multiline Set Key Assignment You use the Multiline Set Key Assignment form to assign the line type, ring type, and directory number to each line select key of the Cyberdata VOIP Indoor Paging Speaker SIP device. Cyberdata VOIP Indoor Paging Speaker SIP device will support up to 1 additional key line appearances. Each key assignment of the Cyberdata VOIP Indoor Paging Speaker SIP device should be defined as multicall type and should specify that a call to the key’s directory number w
ページ15に含まれる内容の要旨
Cyberdata VOIP Indoor Paging Speaker SIP device Setup Notes The following steps show how to program the Cyberdata Indoor Speaker to interconnect with the 3300 ICP. For more detailed configuration or questions about the Cyberdata Indoor Speaker click on the following link: http://www.cyberdata.net/support/voip/ceilingspeaker.html Step 1 Plug network cable into the RJ-45 jack at back of Speaker. The speaker must be plugged into a network switch port that is supplying Power over Eth
ページ16に含まれる内容の要旨
Step 4 The speaker will beep once when it has booted completely. Access the Configuration Portal and click on Speaker Setup. For “Select Speaker Function” choose “SIP” and Save Settings. Document #09-5159-00034 Page 14
ページ17に含まれる内容の要旨
Step 5 Click “SIP Setup”. For “SIP server” and “Outbound Proxy” enter the IP address of the 3300. Enter 5060 for “Remote SIP port” and “Local SIP Port”. Enter the SIP User ID Authenticate ID as the extension programmed in the 3300. Enter the authenticate Password as the Login PIN programmed in the 3300. For SIP Registration select “Yes” Document #09-5159-00034 Page 15