ページ1に含まれる内容の要旨
Polycom RMX™ 4000
Hardware Guide
Version 5.0 | November 2009 | DOC2519A
ページ2に含まれる内容の要旨
Trademark Information Polycom®, the Polycom “Triangles” logo, and the names and marks associated with Polycom’s products are trademarks and/or service marks of Polycom, Inc., and are registered and/or common-law marks in the United States and various other countries. All other trademarks are the property of their respective owners. Patent Information The accompanying product is protected by one or more U.S. and foreign patents and/or pending patent applications held by Polycom, Inc. Portion
ページ3に含まれる内容の要旨
Regulatory Notices United States Federal Communication This equipment does not contain any user Commission (FCC) serviceable part. If trouble is experienced with this equipment RMX 4000, for repair or warranty Part 15: Class A Statement. This equipment has information, please contact Polycom Inc in the U.S.A. been tested and found to comply with the limits for a If the equipment is causing harm to the telephone Class A digital device, pursuant to Part 15 of the FCC network, the telephone co
ページ4に含まれる内容の要旨
Regulatory Notices CE Mark R&TTE Directive Canadian Department of Communications This Class [A] digital apparatus complies with Canadian ICES-003. Polycom Inc., declares that the Polycom RMX™ Cet appareil numérique de la classe A est conforme à 4000 is in conformity with the following relevant la norme NMB-003 du Canada. harmonized standards: Notice: The Industry Canada label identifies certified EN 60950-1:2001 equipment. This certification means that the EN 55022: 1998+A1:2000+A2:2003 cl
ページ5に含まれる内容の要旨
Deutsch [German]: Hiermit erklärt Polycom (UK) Ltd, dass sich das Gerät RMX 4000 in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti [Estonian]: Käesolevaga kinnitab Polycom (UK) Ltd seadme RMX 4000 vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. English: Hereby, Polycom (UK) Ltd. Declares that this RMX 4000 is in compliance with the essen
ページ6に含まれる内容の要旨
Slovensky [Slovak]: Polycom (UK) Ltd týmto vyhlasuje, že RMX 4000 sp ĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi [Finnish]: Polycom (UK) Ltd vakuuttaa täten että RMX 4000 tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Svenska [Swedish]: Härmed intygar Polycom (UK) Ltd att denna RMX 4000 står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som fra
ページ7に含まれる内容の要旨
Polycom RMX 2000/4000 Administrator’s Guide Table of Contents Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Main Features .......................................................................................... 1-1 RMX 4000 Specifications ....................................................................... 1-2 System Capacities ........................................................................... 1-3 MPM+ Resource Capacities .............................
ページ8に含まれる内容の要旨
Table of Contents RMX 4000 LEDs .................................................................................... 1-31 RMX 4000 Front Panel LEDs ....................................................... 1-31 RMX 4000 Rear Panel LEDs ........................................................ 1-34 RTM-IP 4000 .......................................................................... 1-34 RTM LAN .............................................................................. 1-35 RTM ISDN ...........
ページ9に含まれる内容の要旨
1 Hardware Description This Hardware Guide provides information on the RMX 4000 and its components. This system utilizes a modular “universal slot” platform, whose components are designed for high performance, capacity and reliance. Main Features The Polycom RMX 4000 offers the following features: •Linux® based • Chassis based on the ATCA standard • Built-in redundancy, hot swappable parts • Physical network and media separation between management and signaling networks, with high speed swit
ページ10に含まれる内容の要旨
Chapter 1- Hardware Description RMX 4000 Specifications Table 1-1 Polycom RMX 4000 Specifications Physical Height 6U (26.56 cm.) Width 19” (48.26 cm.) Depth 15.74” (40 cm.) Weight Up to 40 Kg. IP Protocols Audio G.711, G.722, G.722.1, G.729A, G.723.1, Siren14. Video H.261, H.263, H.264. Network Interfaces IP, ISDN, PSTN and LAN H.323, SIP, PSTN, LAN and ISDN. Power Supply AC Input/ Range, BTU Voltage range:100-240 VAC, 14-7 AMP, 50/60 Hz. BTU output: 5120. DC Input/Range, BTU Voltage range:-4
ページ11に含まれる内容の要旨
Polycom RMX 4000 Hardware Guide Table 1-1 Polycom RMX 4000 Specifications (Continued) Storage temperature -40°– 70°C (40°– 158°F). Relative humidity 15% - 90% no condensing. Operating altitude 60m below sea level, up to 3,000 m (10,000 ft.). Operating ESD 4kV. System Capacities The following table summarizes the different system capacities. Table 1-2 System Functions and Capacities System Functions Capacity Maximum no. of participants (mixed) in a conference 800 Maximum number of participants (v
ページ12に含まれる内容の要旨
Chapter 1- Hardware Description Table 1-2 System Functions and Capacities System Functions Capacity Maximum number of Log Files (1Mb max.) 8000 Maximum number of CDR Files 4000 Maximum number of Fault Files 1000 Number of Participant alerts Unlimited Number of HTTP (Web) clients connected to the 20 MCU Maximum number Address Book entries 4000 Maximum number of Users 100 MPM+ Resource Capacities Three MPM+ card assemblies are available: MPM+ 80, MPM+ 40 and MPM+ 20 offering various resource ca
ページ13に含まれる内容の要旨
Polycom RMX 4000 Hardware Guide Table 1-4 summarizes the resource capacities of the various video resource types in an RMX containing MPM+ cards. Table 1-4 MPM+ Resource/Port Capacity Resource Type Maximum Capacity (4 MPM+ Cards) Voice 1600 PSTN 400 CIF 320 SD30 120 HD720p 80 HD1080p 40 720p VSW 4Mb 160 1080p VSW 4Mb 160 1080p VSW 6Mb 80 RMX memory size is listed in the Administration > System Information properties box. In HD Video Switching conferences, an RMX with four MPM+ cards can sup
ページ14に含まれる内容の要旨
Chapter 1- Hardware Description Safety Requirements This section describes the requirements your site must meet for safe installation and operation of the system. Site Safety Requirements For your protection, please read these safety instructions completely before operating the equipment. • Look carefully for potential hazards in your work area: moist floors, ungrounded power cables, frayed power cords, missing safety grounds and so forth. • Locate the main circuit breaker within the room.
ページ15に含まれる内容の要旨
Polycom RMX 4000 Hardware Guide General Installation Precautions Attention: The RMX 4000 can weigh up to 40kg when all slots are occupied. Two people are required to lift the MCU out of the box and also when installing it in a rack. • Use a regulating uninterruptable power supply (UPS) to protect the RMX 4000 from power surges and voltage spikes, to keep your MCU operating in case of a power failure. The RMX 4000 requires either two (DC) or three (AC) power supply cables, each connected to a
ページ16に含まれる内容の要旨
Chapter 1- Hardware Description • Always keep the rack’s trays and card’s slots closed when not servicing, to maintain proper cooling. Installing the RMX 4000 The following procedures have to be performed to install the RMX 4000 in your site: • Unpacking the RMX 4000 • Installing the RMX in a rack or as a standalone • Connecting the RMX 4000 to the power source • Connecting the network (LAN, IP and ISDN) cables to the RMX Unpacking the RMX 4000 To unpack and lift the RMX 4000: 1 When you recei
ページ17に含まれる内容の要旨
Polycom RMX 4000 Hardware Guide Make sure that boxes contain all the required parts. 4 Remove the boxes and top Stratocell®. 5 Holding the handle on each side, lift the RMX 4000 from the box, and place it on a flat surface or install it in a rack. Remove any packaging material prior to positioning the RMX 4000. Attention: Two people are required to lift the MCU out of the box and when installing it in a rack. 1-9
ページ18に含まれる内容の要旨
Chapter 1- Hardware Description Installing the RMX in a Rack or as a Standalone Either place the RMX 4000 on a hard, flat surface such as a desktop or mount it on a 19”/23” rack. Standalone RMX 4000 Installation Place the RMX 4000 on a flat surface or desktop. The RMX 4000 must rest on the four feet at the base of the MCU and must be shifted or moved into position using the two handles attached to the front. Rack Mount Preparations • Optional - Depending on the rack installed in your site
ページ19に含まれる内容の要旨
Polycom RMX 4000 Hardware Guide Placing the RMX 4000 in a 19” Rack 1 When the RMX is to be rack mounted chassis runners must be installed on the rack as shown in Figure 1-2. Two chassis runners are included in the Rack Installation Accessories kit and are attached facing inward from the outside of the 19”/23“rack mount. Figure 1-2 Installing chassis runners and RMX in a rack 2 Mount the RMX on top of the rack brackets using the blades or placing it on a rack mount shelf with runners. 1-11
ページ20に含まれる内容の要旨
Chapter 1- Hardware Description 3 Fasten the RMX to the rack with 8 screws into the holes provided on the RMX’s front as shown in Figure 1-3. Figure 1-3 RMX 4000 Rack Mount Rack mounting screws must be supplied by the rack’s manufacturer. The airflow of the RMX 4000 is from right to left. Be sure that the areas on the left and right side of the system are clear for proper ventilation. When the unit is installed on a rack, the rack must be properly grounded to the central office ground. The r