ページ1に含まれる内容の要旨
VIP X1600 B
Network Video Server – Base
en Installation and Operating Manual
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
VIP X1600 B Table of Contents | en 3 Table of Contents 1Preface 5 1.1 About this Manual 5 1.2 Conventions in this Manual 5 1.3 Intended Use 5 1.4 EU Directives 6 1.5 Rating Plate 6 2 Safety Information 7 2.1 Electric Shock Hazard 7 2.2 Installation and Operation 7 2.3 Maintenance and Repair 7 3 Product Description 9 3.1 Scope of Delivery 9 3.2 System Requirements for Setup 9 3.3 Configuration and Operation 9 3.4 Overview of Functions 10 3.5 Connections and Displays 11 4 Installation 13 4.1 Prepa
ページ4に含まれる内容の要旨
4 en | Table of Contents VIP X1600 B F.01U.081.492 | V4.0 | 2008.04 Installation and Operating Manual Bosch Security Systems
ページ5に含まれる内容の要旨
VIP X1600 B Preface | en 5 1Preface 1.1 About this Manual This manual is intended for persons responsible for the installation and operation of the VIP X1600 B. International, national and any regional electrical engineering regulations must be followed at all times. Relevant knowledge of network technology is required. The manual describes the installation and operation of the VIP X1600 B base. 1.2 Conventions in this Manual In this manual, the following symbols and notations are used to dra
ページ6に含まれる内容の要旨
6 en | Preface VIP X1600 B 1.4 EU Directives The VIP X1600 B network video server complies with the requirements of EU Directives 89/ 336 (Electromagnetic Compatibility) and 73/23, amended by 93/68 (Low Voltage Directive). 1.5 Rating Plate For exact identification, the model name and serial number are inscribed on the rating plate on the bottom of the VIP X1600 B base and on the rating plates on the circuit boards of the modules. Please make a note of this information before installation, if n
ページ7に含まれる内容の要旨
VIP X1600 B Safety Information | en 7 2Safety Information 2.1 Electric Shock Hazard – Never attempt to connect the unit to any power network other than the type for which it is intended. – Use only power supply units approved by Bosch Security Systems. – Never open the housing of the power supply unit. – Always install a module in the appropriate VIP X1600 B base housing only. – If a fault occurs, disconnect the VIP X1600 B from the power supply and from all other units. – Install the power su
ページ8に含まれる内容の要旨
8 en | Safety Information VIP X1600 B F.01U.081.492 | V4.0 | 2008.04 Installation and Operating Manual Bosch Security Systems
ページ9に含まれる内容の要旨
VIP X1600 B Product Description | en 9 3 Product Description 3.1 Scope of Delivery –VIP X1600 B base – Mounting kit for installation in 19-inch racks – Self-adhesive elastic bumpers – Quick Installation Guide – Product CD with the following content: – Quick Installation Guide –Manual – System Requirements document – Further documentation on Bosch Security Systems products – Configuration Manager –MPEG ActiveX control – Player and Archive Player –DirectX control – Microsoft Internet Explorer – Su
ページ10に含まれる内容の要旨
10 en | Product Description VIP X1600 B 3.4 Overview of Functions 3.4.1 Network Video Server Housing The VIP X1600 B base is a special housing for the installation of up to four standalone modules. Encoder modules (senders), for the connection of up to four cameras each, and decoder modules (receivers), for the connection of up to four monitors each, are available. For example, a VIP X1600 B with four encoder modules can make up to 16 independent video channels available. Combinations of enc
ページ11に含まれる内容の要旨
VIP X1600 B Product Description | en 11 3.5 Connections and Displays 1 Installed module 2 Cover for vacant slot 3ETH1 RJ45 socket for connection to the network or an iSCSI system 4 Sockets for connecting one or two power supply units 5ETH2 RJ45 socket for connection to the network or an iSCSI system 6 LEDs, status information for the modules and the VIP X1600 B base NOTICE! For more information about the LEDs, see Section 6.2 LEDs, page 21. i Bosch Security Systems Installation and Operating Ma
ページ12に含まれる内容の要旨
12 en | Product Description VIP X1600 B F.01U.081.492 | V4.0 | 2008.04 Installation and Operating Manual Bosch Security Systems
ページ13に含まれる内容の要旨
VIP X1600 B Installation | en 13 4 Installation 4.1 Preparations The VIP X1600 B base is designed for installation in a switch cabinet. Mounting the unit in a 19-inch rack using the installation material supplied is a quick and easy operation. It is also possible to operate this as a desktop unit. The four elastic bumpers included in the scope of delivery ensure a non-slip support. CAUTION! The unit is designed for indoor operation. Select a suitable location for installation that guarantees
ページ14に含まれる内容の要旨
14 en | Installation VIP X1600 B 4.3 Installing in a Switch Cabinet 4.3.1 Preparations The VIP X1600 B is set up for installation in a 19-inch rack. The necessary installation equipment is included in the scope of delivery. CAUTION! When installing in a switch cabinet, ensure that there is sufficient ventilation for the unit. There must be at least 5 cm (1.97 in.) of free space to the left and right of the unit and at least 10 cm (3.94 in.) at the rear. The VIP X1600 B generates heat during
ページ15に含まれる内容の要旨
VIP X1600 B Installation | en 15 Bosch Security Systems Installation and Operating Manual F.01U.081.492 | V4.0 | 2008.04
ページ16に含まれる内容の要旨
16 en | Installation VIP X1600 B 4.4 Connections 4.4.1 Network You can connect the VIP X1600 B to a 10/100/1000 Base-T network using a standard UTP category 5 cable with RJ45 plugs. The Ethernet interfaces can be used to create one or more redundant connections to the network. NOTICE! You cannot create a connection to a second network. i 1. Connect the VIP X1600 B to the network via the ETH1 or ETH2 socket. 2. Connect the VIP X1600 B to a redundant switch or hub on the same network via the s
ページ17に含まれる内容の要旨
VIP X1600 B Installation | en 17 4.5 Power On/Power Off 4.5.1 Power Supply The VIP X1600 B does not have a power switch. Power is provided once one or two separate power supply units have been installed. Connect the VIP X1600 B to a power supply unit and plug this into the mains. The unit is now ready for use. The VIP X1600 B does not come supplied with a power supply unit. CAUTION! Use only power supply units approved by Bosch Security Systems. Where necessary, use suitable equipment to en
ページ18に含まれる内容の要旨
18 en | Installation VIP X1600 B F.01U.081.492 | V4.0 | 2008.04 Installation and Operating Manual Bosch Security Systems
ページ19に含まれる内容の要旨
VIP X1600 B Maintenance and Upgrades | en 19 5 Maintenance and Upgrades 5.1 Testing the Network Connection You can use the ping command to check the connection between two IP addresses. This allows you to test whether a unit in the network is active. 1. Open the DOS command prompt. 2. Type ping followed by the IP address of the unit. If the unit is found, the response appears as Reply from ... followed by the number of bytes sent and the transmission time in milliseconds. If not, the unit can
ページ20に含まれる内容の要旨
20 en | Maintenance and Upgrades VIP X1600 B F.01U.081.492 | V4.0 | 2008.04 Installation and Operating Manual Bosch Security Systems