ADCTDN2412N_P_EN.book Page 1 Friday, September 28, 2007 12:49 PM
TRUE D/N CAMERA
INSTRUCTIONS
ADCTDN2412N
ADCTDN2412P
ADCTDN0230P
For Customer Use:
Enter below the Serial No. which is located on the
body. Retain this information for future reference.
Model No.
Serial No.
LST0617-001A
8200-0852-00-A0
ページ2に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 2 Friday, September 28, 2007 12:49 PM FOR USA These are general IMPORTANTSAFEGUARDS and certain items may not apply to all appliances. IMPORTANTSAFEGUARDS Readall of theseinstructions. 1. 2. Save theseinstructions for lateruse. 3. All warnings on the productand in the operating instructionsshouldbe adhered to. 4. Unplug thisappliancesystem from the wall outletbefore cleaning. Do notuse liquid cleaners oraerosol cleaners.Usea damp cloth for cleaning. 5. Do notuseatta
ページ3に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 3 Friday, September 28, 2007 12:49 PM Do notallowanything to rest on the power cord. Do not locate this 11. appliance where the cord willbeabusedby persons walking on it. 12. Followall warningsand instructions marked on theappliance. Do not overloadwall outletsand extension cordsas this canresult in 13. fire or electricshock. 14. Never pushobjects ofany kind into thisappliance through cabinetslots as they maytouch dangerous voltage points orshort outparts that could
ページ4に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 4 Friday, September 28, 2007 12:49 PM Introduction Safety Precautions FOR USA AND CANADA CAUTION RISK OF ELECTRICSHOCK DO NOT OPEN : TO REDUCE THE RISK OF ELECTRIC SHOCK. CAUTION DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE.REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flashwisharrowheadsymbol, withinan equilateral triangle isintended toalert theuser to the presence ofuninsulated "dangerous voltage" within the product's enclosure t
ページ5に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 5 Friday, September 28, 2007 12:49 PM INFORMATION FOR USA INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limitsare designed to provide reasonable protection against harmful interference in a residentialinstallation. This equipment generates, uses, and canradiate radio frequency energy and, if not installed and used in accordance with the instructions,may causeha
ページ6に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 6 Friday, September 28, 2007 12:49 PM Introduction Safety Precautions (continued) Information for Users on Disposal of Old Equipment [European Union] Thissymbol indicates that the electricaland electronic equipment should notbedisposedas generalhousehold wasteatits end-of- life. Instead, the productshouldbehanded over to theapplicable collection point for the recycling of electricaland electronic equipment for proper treatment, recoveryand recycling in accordance wi
ページ7に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 7 Friday, September 28, 2007 12:49 PM POWER SYSTEM ADCTDN0230P thisunit operates on a mainssupply voltage of 220V to 240V AC, 50/60HZ. ADCTDN2412N/P these unitsare to be powered by DC 12V or anAC 24V power supply. The AC 24V and DC 12V should conform to the following: Class 2 only (for USA), isolated power supply only (for Europe). CAUTION To prevent electric shock, do not open the cabinet. No user serviceable parts inside. Refer servicing to qualified service perso
ページ8に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 8 Friday, September 28, 2007 12:49 PM Introduction Thank you for using American Dynamics products. We support our products through an extensive worldwide network of dealers. The dealer through whom you originally purchased this product is your point of contact if you need service or support. Our dealers are empowered to provide the very best in customer service and support. Dealers should contact American Dynamics at (800) 507- 6268 or (561) 912-6259 or on the W
ページ9に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 9 Friday, September 28, 2007 12:49 PM Contents Introduction Safety Precautions ....................................................................................... 4 Features ....................................................................................................... 8 Contents .......................................................................................................9 Operating Precautions ..................................................
ページ10に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 10 Friday, September 28, 2007 12:49 PM Introduction Operating Precautions Storage and Location of Use This camera has been designed for indoor use. When you use it outdoors, be sure to use a housing or the like. Do not install or use the camera in the following places. ● In a place exposed to rain or moisture. ● In a place with vapor or oil, for example in a kitchen. ● When the ambient temperature rises above or falls below the acceptable range (from -10 I to
ページ11に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 11 Friday, September 28, 2007 12:49 PM Others This camera comes with a built-in AGC circuit. The sensitivity increases automatically at a dark place and the screen may appear grainy. This is not a malfunction. While the AGC is activated, if a transceiver which causes strong electromagnetic wave is used near the camera, the picture may suffer from beat. Please use the camera more than five meters from such transceivers. You may hear some noise during powe
ページ12に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 12 Friday, September 28, 2007 12:49 PM Introduction Name of Parts and their Functions Front/Bottom/Side panel A J I B H C D G IRIS VIDEO E DC F LEVEL A Back focus adjustment ring This ring switches between back focus adjustment and lens mounting method. When adjustment is required, loosen the back focus locking screw J by turning it anti-clockwise. After the adjustment, tighten the locking screw by turning it clockwise. This camera is factory-adjusted to a suitabl
ページ13に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 13 Friday, September 28, 2007 12:49 PM D [IRIS] Iris Terminal This is connected to an autoiris control lens. E [VIDEO,DC] Iris Selector Switch This should be set according to the type of lens if an autoiris control lens is used. VIDEO : In case of lens with EE amp built-in DC : In case of lens without EE amp built-in (Default setting: DC)(A Pg. 18) F [LEVEL] Iris Level Adjustment Dial This adjusts the iris level of the autoiris control lens. Usually, adjustment is
ページ14に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 14 Friday, September 28, 2007 12:49 PM Introduction Name of Parts and their Functions (continued) Back panel ADCTDN2412 R CLASS 2 ONLY SEE INSTRUCTION ISOLATED POWER ONLY MANUAL Q POWER K + DC12V d INT LL P 1 2 AC24V H MENU O SET L VIDEO OUT N SELECTOR M ADCTDN0230P R S SEE INSTRUCTION MANUAL POWER Q INT LL P MENU O SET L VIDEO OUT N SELECTOR M 14
ページ15に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 15 Friday, September 28, 2007 12:49 PM K [AC24V,DC12V] Power input terminal To connect to AC 24 V or DC 12 V power supply. (A Pg. 21) L [AUX,GND] External terminals This terminal is for the input/output signals that are set in the AUX MODE of the AUX FUNCTION screen. (A Pg. 36) ● This terminal also outputs the B&W/Color signal. [Open-collector L signal. Maximum voltage 25 V, current 30 mA] ● When switching B&W/Color using the control signal, the signals are input
ページ16に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 16 Friday, September 28, 2007 12:49 PM Introduction Name of Parts and their Functions (continued) Q [POWER] Power indicator lamp This lamp lights up when power is supplied to the camera. R Mounting Screw for Fall Prevention Wire Use this screw when mounting the fall prevention wire to this unit. (Fall prevention wire is not supplied with this product.) Note: ● Connect the fall preventi
ページ17に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 17 Friday, September 28, 2007 12:49 PM Setup Flow for Connection/Settings Follow the procedures below to connect/set this unit. Turn off the power of devices to be used before connecting the cables. Mounting the lens (A Pg.18) step 1 Mount the lens. K Connecting the back panel (A Pg. 20) step 2 Connect the control signal cable, video signal coaxial cable and the like. K Mounting the camera (A Pg. 23) step 3 Mount the camera to the mounting location. K Adjusting the
ページ18に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 18 Friday, September 28, 2007 12:49 PM Setup Mounting the lens 1 (a) F (b) 3 VIDEO DC 2 IRIS VIDEO DC LEVEL 4 pin plug 1 3 4 2 4 3 1 4 2 18
ページ19に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 19 Friday, September 28, 2007 12:49 PM 1. Check the mounting method of the lens before mounting ● This camera is set to CS-mount lens before shipment. To use a C-mount lens, loosen the back focus locking screw with a screwdriver, turn the back focus adjustment ring with your finger or the screwdriver and change the mounting method. ● For the dimension (a) of the lens mounting section as illustrated in the diagram, use the value that is shown in the table below.
ページ20に含まれる内容の要旨
ADCTDN2412N_P_EN.book Page 20 Friday, September 28, 2007 12:49 PM Setup Connecting the back panel Connect to AC 24 V or Connect to AC 220 DC 12 V power supply V-240 V power supply (ADCTDN2412N/P) (ADCTDN0230P) R CLASS 2 ONLY SEE INSTRUCTION ISOLATED POWER ONLY MANUAL POWER + DC12V d INT LL 1 2 AC24V H MENU AUX GND SET VIDEO OUT Monitor SELECTOR To the terminal of infrared illumination device etc. (A Pg. 22) When you install in a place where noise tend to appear, please use a cable with