ページ1に含まれる内容の要旨
INST ALLA TION
®
Spectra Mini IP
Dome System
C3446M (7/08)
ページ2に含まれる内容の要旨
Contents Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 System Models.
ページ3に含まれる内容の要旨
List of Illustrations 1 DHCP Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2 Endura Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3 Private Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4 Static Network Example. . . . . . . . . . .
ページ4に含まれる内容の要旨
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 7. Only use attachments/accessories specified by the manufacturer. 8. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus. 9. In
ページ5に含まれる内容の要旨
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provi
ページ6に含まれる内容の要旨
Description ® The Spectra Mini IP dome system is an indoor mini dome system with a built-in 100Base-TX network ® ® ® interface for live streaming to a standard Web browser (Microsoft Internet Explorer or Firefox ). The Spectra Mini IP dome features open architecture connectivity for third-party software recording solutions ™ and is also Endura Enabled to record, manage, configure, and view multiple live streams. The Spectra Mini IP also includes built-in Power over Ethernet (PoE), which supp
ページ7に含まれる内容の要旨
PARTS LIST The following parts are supplied with the Spectra Mini IP dome system: Qty Description 1 Dome drive 1 Dome bubble with trim ring 1 Installation manual (C3446M) 1 Operation/Configuration manual (C3447M) 1 Spring paddle flex assembly 1 Hardware kit 2 #10 x 1.50-inch self-tapping screws for suspended ceiling installation 2 #8-32 x 3.50-inch machine screws for suspended ceiling installations 2 #8 x 3.50-inch self-tapping screws for surface mount installation The following parts, in additi
ページ8に含まれる内容の要旨
BASIC SYSTEM CONFIGURATIONS The following illustrations demonstrate the possible configurations of Spectra Mini IP with a variety of network options. IMPORTANT NOTE. PLEASE READ. The network implementations in this document are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. Please contact your local Pelco Repres
ページ9に含まれる内容の要旨
DHCP NETWORK In this configuration, the DHCP network is accessed through the Web browser. NOTE: For a secure network, Pelco recommends placing the dome behind a firewall. Refer to Table A on page 8. Figure 1. DHCP Network Example ENDURA NETWORK Refer to Table A on page 8. Figure 2. Endura Network Example C3446M (7/08) 9
ページ10に含まれる内容の要旨
PRIVATE NETWORK When using a private network, the PC used to operate the Web browser acts as the server. If a static IP network is being used rather than a DHCP network, the dome system is assigned a default IP address of 192.168.0.20 on netmask 255.255.0.0. After the first dome system is plugged in and recognized on a static IP network, you must manually change the IP address of the dome system before plugging in any additional dome systems. Plugging in a second dome system before changing
ページ11に含まれる内容の要旨
STATIC NETWORK When using a static network, the PC used to operate the Web browser must use the same subnet mask as the dome systems to which it is connected. When the first dome system is plugged into the network, it is assigned a default IP address of 192.168.0.20 on netmask 255.255.0.0. After the first dome system is plugged in and recognized on a static IP network, you must manually change the IP address of the dome system before plugging in any additional dome systems. Plugging in a seco
ページ12に含まれる内容の要旨
Cover and Back Box Installation The Spectra Mini IP is an indoor dome system designed for ceiling applications. The dome can be mounted to the surface of ceilings, or it can be recessed in hard ceilings or standard 2 x 2 ft (61 x 61 cm) tiles in suspended ceilings. SURFACE MOUNT INSTALLATION 1. Prepare the ceiling as follows: a. Using the surface mount ring as a template, drill holes for the mounting hardware. • Standard ceiling: When mounting the dome system to a standard ceiling, use either
ページ13に含まれる内容の要旨
Figure 5. Ceiling Installation Figure 6. Concrete Ceiling Installation 6-32 Toggle Bolts (not supplied) #8 x 3.50-Inch Self-Tapping Screws (supplied) NOTE: Use either toggle bolts or self-tapping screws when mounting the dome to a standard ceiling. 8-32 Studs (not supplied) Nuts (not supplied) C3446M (7/08) 13
ページ14に含まれる内容の要旨
RECESSED INSTALLATION SUSPENDED CEILING 1. Remove the spring paddle flex assembly from the surface mount ring (refer to Figure 7). Figure 7. Spring Paddle Flex Assembly 2. Remove the surface mount ring from the dome drive as follows (refer to Figure 8 on page 15): a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the dome drive. 3. Attach the spring paddle flex assembly to the dome drive using
ページ15に含まれる内容の要旨
1LINE OUT + 2LINE OUT - 3LINE IN + 4LINE IN - 5AUX + 6AUX - 7ALARM- 8ALARM+ 9. Line up the tabs on the trim ring with the slots in the dome drive. Snap the trim ring and dome bubble into place. Figure 8. Removing the Surface Mount Ring Figure 9. Recessed Installation Spring Paddle Flex Assembly #8-32 x 3.50-Inch Machine Screws C3446M (7/08) 15
ページ16に含まれる内容の要旨
HARD CEILING 1. Remove the spring paddle flex assembly from the surface mount ring. 2. Remove the surface mount ring from the dome drive as follows (refer to Figure 8 on page 15): a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the dome drive. 3. Attach the spring paddle flex assembly to the dome drive using the two #8-32 x 3.50-inch machine screws (supplied). Thread the screws into the end
ページ17に含まれる内容の要旨
Wiring Tables CAT5 CABLE Connect a Cat5 cable to the RJ-45 network connector. The 8-pin RJ-45 connector includes video and PoE for the dome system. PoE (IEEE 802.3af) injects power over the same cabling that carries the network data, eliminating the need for a separate power supply; this simplifies the installation and operation of the dome system without any degradation of network performance. Refer to Figure 10 for pin descriptions. Figure 10. Wiring Diagram 8-Position Terminal Block • Pin
ページ18に含まれる内容の要旨
24 VAC CONNECTIONS (OPTIONAL) If PoE is not used, the camera includes a 24 VAC power connector. Connect the power cable to the 2-pin power connector on the back of the camera using the terminal block connector (provided). Refer to Recommended Wire Gauge and Wiring Distances on page 18. The power supply connector is shown in Figure 6. Use only a Class 2 isolated power supply. Refer to Specifications on page 25 for power consumption. The following are the recommended maximum distances for 24 VA
ページ19に含まれる内容の要旨
CONNECTING ALARMS The Spectra Mini IP provides an alarm input for external signaling devices, such as door contacts or motion detectors. Both normally open and normally closed devices are supported. SUPERVISED ALARMS When an alarm is configured as a supervised alarm, Spectra Mini IP maintains a constant electrical current through the alarm circuit (3.3 VDC, 1 kohm). If the alarm circuit length changes, due to an electrical short or a bypass, the voltage fluctuates from its normal state. There
ページ20に含まれる内容の要旨
UNSUPERVISED ALARMS When an alarm is configured as an unsupervised alarm, the dome system only triggers an alarm when the normal alarm state (normally open or normally closed) changes. Figure 15 shows the alarm and no alarm conditions of an unsupervised alarm input. A normally closed alarm input can be defeated with a bypass; a normally open input can be defeated with a cut. Figure 16 and Figure 17 show the wiring configuration for unsupervised alarm inputs. NORMALLY CLOSED NORMALLY OPEN NO AL