ADDENDUM
Addendum No. C1531M
Date October 25, 2005
Manuals Affected C1525M-B
Manual Update Installation of Support Rails
The instructions provided in this section replace the steps listed on page 11 of the Installation/Operation manual for
installing the VMX200 in a 19-inch equipment rack.
Connecting Analog Video to the VMX200-SYS-Q
The instructions provided in this section replace the steps listed on page 15 of the Installation/Operation manual for
connecting analog video input
ページ2に含まれる内容の要旨
Connecting Analog Video to the VMX200-SYS-Q The video input card that is supplied with the VMX200-SYS-Q has changed, and now it has only four video input connectors. The original configuration described in the VMX200 Installation/Operation manual included the yellow input connector. Now the configuration uses the black input connector instead of the yellow. To connect video inputs to the VMX200-SYS-Q, complete the following steps and refer to Figure 2: 1. Connect the “spider” video in
ページ3に含まれる内容の要旨
INSTALLATION/OPERATION VMX200 Video Management System ® VMX200-SYS Series C1525M-B (10/02)
ページ4に含まれる内容の要旨
2 C1525M-B (10/02)
ページ5に含まれる内容の要旨
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................................................................................................. 4 DESCRIPTION ..................................................................................................................................................................................................................... 5 MODELS ............................................
ページ6に含まれる内容の要旨
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed: 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. The installation method and materials should be capable of suppor
ページ7に含まれる内容の要旨
DESCRIPTION ® The Pelco VMX200 Video Management System uses a Windows -based interface for video security system control. You can ® ™ control matrix switchers, multiplexers, DVRs, VCRs, and Spectra /Esprit camera positioning systems by using mapping configurations and a visual interface. With a mouse, you can click a camera icon within your site map and drag it to a video display window. The VMX200 uses an interactive system schematic to simplify system configuration. This unique technique autom
ページ8に含まれる内容の要旨
OVERVIEW Figure 1 shows how equipment can be linked together on the VMX200 Video Management System. This illustration is only an example. There are many ways you can link equipment together in this system. NOTE: Each VMX200 workstation has two standard COM ports. Expansion is possible via the USB port. DATA VIDEO MULTIPLEXER DVR MATRIX SWITCHER VCR VMX200-SYS-Q MONITOR WALL Figure 1. System Overview 6 C1525M-B (10/02)
ページ9に含まれる内容の要旨
FRONT VIEW Refer to Figure 2 to get familiarized with the front of the VMX200 workstation. The front of the unit has a door that can be opened or locked using one of the supplied keys. Figure 2. VMX200 Front View POWER LED RACK EARS HDD (HARD DISK DRIVE) LED FAN KEY LOCK (2 KEYS SUPPLIED) POWER BUTTON FAN VENTILATION CD-RW DRIVE HANDLES 3.5-INCH FLOPPY DRIVE C1525M-B (10/02) 7
ページ10に含まれる内容の要旨
REAR VIEW Figure 3 shows the rear of each VMX200 model. This system does not require the use of all of the ports. VMX200-SYS
VMX200-SYS-1 VMX200-SYS-Q Figure 3. VMX200 Rear View 8 C1525M-B (10/02)
ページ11に含まれる内容の要旨
VMX200-SYS MOUSE PORT MONITOR PORT KEYBOARD PORT ETHERNET PORT (NOT USED) USB PORT (NOT USED) S-VHS VIDEO PORT (NOT USED) COM 1 F CONNECTOR PORT (NOT USED) COM 2 PARALLEL PORT*** VIDEO INPUT* VMX200-SYS-1 MOUSE PORT LEFT MONITOR PORT ETHERNET PORT (NOT USED) KEYBOARD PORT USB PORT (NOT USED) DB15 PORT (NOT USED) COM 1 S-VHS VIDEO PORT (NOT USED) COM 2 F CONNECTOR PORT (NOT USED) VIDEO INPUT*
PARALLEL PORT*** RIGHT MONITOR PORT VMX200-SYS-Q
ページ12に含まれる内容の要旨
INSTALLATION The following items are supplied: •1 VMX200 workstation •1 Mouse •1 Keyboard •1 Video input adapter •1 Y adapter (VMX200-SYS-Q) or 1 plug adapter (VMX200-SYS-1) •2 Power cords (1 USA standard and 1 European standard) •2 Adjustable support rails with screws and nuts •2 Rack-mount ears with screws •2 Keys •1 Video input card software package •1 VMX200 system software package •1 Windows 2000 startup package One VGA or SVGA monitor is required for the VMX200-SYS and two VGA or SVGA moni
ページ13に含まれる内容の要旨
MOUNTING The VMX200 can be placed on a flat surface, such as a shelf or table, or it can be mounted in a 19-inch (48.26 cm) equipment rack. Follow these instructions to mount the workstation in an equipment rack: 1. Attach the two adjustable support rails to the sides of the equipment rack using the eight 10-32 x .375-inch screws. Also use the eight 10-32 nuts if the rack does not have threaded mounting holes. 2. Tighten the eight 10-32 x .250 screws. 3. Attach the two rack ears to the front sid
ページ14に含まれる内容の要旨
CONNECTIONS MOUSE AND KEYBOARD Connect the mouse and keyboard to the workstation. Figure 5 shows the VMX200-SYS model, but the connections are the same for the other two models. VMX200-SYS Figure 5. Mouse and Keyboard Connections 12 C1525M-B (10/02)
ページ15に含まれる内容の要旨
MONITOR OUTPUTS If you have the VMX200-SYS model, you have to connect only one monitor. The VMX200-SYS-1 and VMX200-SYS-Q each require two monitors. Refer to Figure 6. The VMX200-SYS-Q uses an overlay. This allows a quad display. The location of the monitors is important. The graphical map monitor must always be placed on the left and the video display monitor must always be placed on the right. VMX200-SYS VGA MONITOR VMX200-SYS-1 LEFT VGA RIGHT VGA MONITOR MONITOR VMX200-SYS-Q DB15 LEFT VGA RIG
ページ16に含まれる内容の要旨
VIDEO INPUTS The VMX200-SYS and VMX200-SYS-1 have one video input. The VMX200-SYS-Q has six video inputs. Follow these steps and refer to Figure 7 to connect the video: 1. Connect a spider cable to the video port on each model. 2. Connect the video input to the video source (for example, cameras or monitor output of a switch or multiplexer). NOTE: Refer to the Installation/Operation Manual for each device you connect for further video connection information. For the VMX200-SYS and VMX200-SYS-1,
ページ17に含まれる内容の要旨
VMX200-SYS S-VIDEO IN (BLACK) SPIDER AUDIO IN RIGHT (RED) CABLE AUDIO IN LEFT (WHITE) VIDEO IN (YELLOW) * * REQUIRES RCA-TO-BNC ADAPTER VMX200-SYS-1 S-VIDEO IN (BLACK) SPIDER AUDIO IN RIGHT (RED) CABLE AUDIO IN LEFT (WHITE) VIDEO IN (YELLOW) * REQUIRES RCA-TO-BNC ADAPTER * VMX200-SYS-Q INPUT COLOR 1 RED SPIDER 2 GREEN CABLE 3 BLUE 4 YELLOW 5 BLACK 6 WHITE Figure 7. Video Inputs C1525M-B (10/02) 15
ページ18に含まれる内容の要旨
DATA CONTROL The following sections provide instructions and illustrations on how to connect numerous devices to the VMX200 for data control. Each application shows a VMX200-SYS for illustration purposes only. You can also use a VMX200-SYS-1 or VMX200-SYS-Q. NOTE: You can use either COM 1 or COM 2 on the VMX200 for control. SPECTRA/ESPRIT CONTROL CONNECTIONS To connect a Spectra or Esprit to a VMX200 for direct camera control, you must use a PV130 converter to convert the RS-232 interface to an
ページ19に含まれる内容の要旨
CM6800 CONTROL CONNECTIONS There are two ways you can connect a CM6800 to a VMX200. Connect a null modem cable from VMX200 COM 1 or COM 2 to the CM6800 COM 1 port. Connect a DB9 cable from VMX200 COM 1 or COM 2 to the CM6800 ASCII Ports 2, 7, or 8. You must use a wall block to convert the DB9 connector to an RJ-45 connector. Figure 9. CM6800 Control Connections Although a CM6800-48X8 is pictured above, you can use a CM6800-32X6 as long as the COM port number of the port connection is the sa
ページ20に含まれる内容の要旨
CM6700 CONTROL CONNECTIONS Follow these steps and refer to Figure 10: 1. Connect a DB9 cable from VMX200 COM 1 or COM 2 to the screw terminal connector on the CM6700. Note the pin-outs on the wiring. 2. Remove the cover from the CM6700-MXB and set the SW5 DIP switch to RS-232 mode. Replace the cover when done. After you make the connections, open the Device Configuration window in the VMX200 software and add the CM6700 to your system. Refer to the VMX200 Software Installation/Operation Manual fo