ページ1に含まれる内容の要旨
®
QuickScan QS2500
Handheld Bar Code Scanner
Product Reference Guide
ページ2に含まれる内容の要旨
PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. or its wholly owned subsid- iaries ("PSC"). Owners of PSC products are hereby granted a non-exclusive, revocable license to reproduce and transmit this doc- umentation for the
ページ3に含まれる内容の要旨
Installation ......................................................................................... 1 Keyboard Wedge .........................................................................................1 Wand Emulation .........................................................................................1 RS-232 ......................................................................................................1 USB ....................................................................
ページ4に含まれる内容の要旨
PDF417 ....................................................................................................57 Italian PharmaCode ...................................................................................58 RSS Expanded ..........................................................................................59 RSS Limited ..............................................................................................60 RSS-14 ...............................................................
ページ5に含まれる内容の要旨
Installation Complete the following steps for the appropriate interface. Keyboard Wedge 1. Turn off the terminal or computer. 2. Disconnect the keyboard cable from the back of the terminal or computer. 3. Connect the QS2500 to the terminal or computer using the appro- priate interface cable. 4. Turn the terminal or computer back on. Wand Emulation 1. Turn off the terminal or computer. 2. Connect the appropriate interface cable to the terminal or com- puter. 3. Turn the terminal or computer on.
ページ6に含まれる内容の要旨
USB 1. Plug the USB cable into the terminal or computer. If the QS2500 does not operate, turn off the terminal or computer immediately and check all connections. If necessary, go through the above steps again. NOTE IBM 1. Turn off the terminal or computer. 2. Connect the appropriate interface cable to the terminal or com- puter. 3. Turn the terminal or computer on. 2 QS2500
ページ7に含まれる内容の要旨
Programming the QS2500 To program the QS2500, you must scan a series of programming bar codes in the correct order. The inside back cover of this manual contains a table of alphanumeric bar codes needed to program the various options. To program each option: 1. Scan the Start Program bar code above the list of options (see the table below). 2. Enter the option mode by scanning the Option bar code. 3. Find the alphanumeric entry for the option setting you want, and scan the alphanumeric chara
ページ8に含まれる内容の要旨
Resetting the QS2500 To return all QS2500 option settings to the factory defaults, scan the fol- lowing two bar codes, in the order shown: Start Program Default Value Initialization Interfaces The QS2500 supports Keyboard Wedge, RS-232, Wand Emulation, IBM and USB interfaces. The correct interface cable is included for the scanner interface type you ordered. Keyboard Wedge As a keyboard interface, the QS2500 supports most popular PCs and IBM terminals. The installation of the wedge is a fairl
ページ9に含まれる内容の要旨
Start Program Alphanumeric Option Bar Code Option Entry IBM AT, PS/2 00* Keyboard Type Reserved 01 - 06 USA 00* Belgium 01 Keyboard Layout Danish 02 France 03 Germany 04 Italian 05 Portuguese 06 Spanish 07 Swedish 08 Switzerland 09 UK 10 Latin American 11 Japan 12 0–8 (0 = high clock 00–08 Keyboard Speed rate; 01* 8 = low clock rate) Exit $$ Function Key: When this option is enabled, the QS2500 outputs bar code ASCII values from 01 to 1F as function-key presses in your applica- hex hex tion.
ページ10に含まれる内容の要旨
Numeric Key: If your application accepts only keypad numeric code, use setting 01 to make the QS2500 output code as numeric-keypad presses when it reads digits. If you use setting 02, the scanner will send the three digit ACSCII number for all data using the Alt and numeric keypad key- codes. Setting 02 prevents the caps Lock from affecting scanner data. Caps Lock: By selecting Caps Lock or No Caps Lock, the QS2500 can get Caps Lock status. Power-On Simulation: All PCs check the keyboard sta
ページ11に含まれる内容の要旨
Start Program $ Alphanumeric Option Bar Code Option Entry Disable 00* Function Key Enable 01 Alphabetic key 00* Numeric Key Numeric keypad 01 only Alt+Keypad 02 Caps lock 00 Caps Lock No caps lock 01* Disable 00* Power-On Simulation Enable 01 0–99 (msec.) 00–99 02* Intercharacter Delay 0–99 (10 msec.) 00–99 Block Transmission 10* Delay Exit $$ Product Reference Guide 7
ページ12に含まれる内容の要旨
Wand Emulation Support for wand emulation is available only with the keyboard wedge interface. Use the bar codes below to enable and config- ure wand emulation. NOTES Start Program $ Alphanumeric Option Bar Code Option Entry Keyboard Wedge 00* Interface selection Wand Emulation 02 Bar high/Space 00* low Bar/Space Polarity Bar low/Space 01 high Idle low 00* Idle Polarity Idle high 01 660 00 Output Speed (pixels per 1250 01 second) 2500 02 5000 03* 10000 04 20000 05 8 QS2500
ページ13に含まれる内容の要旨
Alphanumeric Option Bar Code Option Entry 15 (Default) 15* 00–99 (x 10 pixels) 00–99 Margin Delay (pixels) 30 (default) 30* 00–99 (x 10 msec.) Transmit Delay 00–99 (Milliseconds) Exit $$ Product Reference Guide 9
ページ14に含まれる内容の要旨
RS-232 Alphanumeric Option Bar Code Option Entry 300 Baud 00 Baud Rate 600 Baud 01 1200 Baud 02 2400 Baud 03 4800 Baud 04 9600 Baud 05* 19200 Baud 06 38400 Baud 07 None 00* Parity Odd 01 Even 02 8 bits 00* Data Bit 7 bits 01 1 bit 00* Stop Bit 2 bits 01 Exit $$ CTS = Clear To Send (Hardware Signal) RTS = Request To Send (Hardware Signal) Xon = Transmit On (ASCII Code 11 ) hex Xoff = Transmit Off (ASCII Code13 ) hex ACK = Acknowledge (ACSII Code 06 ) hex NAK = Not Acknowledge (ASCII Code 15 ) he
ページ15に含まれる内容の要旨
RS-232 Advanced Features Flow Control None: The communication uses only TxD and RxD signals, without regard for any hardware or software handshaking protocol. RTS/CTS: If the QS2500 wants to send the bar code data to the host com- puter, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data com- munication. If there is no replied CTS signal from the host com- puter after the timeout (response delay) duration, the QS2500 will issue
ページ16に含まれる内容の要旨
RS-232 Advanced Features — continued Response Delay This delay is used for serial communication. It is the amount of time the QS2500 waits for handshaking acknowledgment from the host computer. Start Program $ Alphanumeric Option Bar Code Option Entry None 00* Flow Control RTS/CTS 01 Xon/Xoff 02 ACK/NAK 03 a PSC Aux. Port 04 Mode B 05 0–99 (msec.) 00–99 00* Intercharacter Delay 0–99 (10 msec.) 00–99 Block Transmission 00* Delay 0–99 (100 msec.) 00–99 20* Response Delay Exit $$ a. Reading P
ページ17に含まれる内容の要旨
IBM Interface (46XX/USB) The next few pages contain the programming labels for configuring the IBM interface to match your interface configuration and symbology spe- cific requirements. Start Program Alphanumeric Option Bar Code Option Entry IBM 46xx port 17 00 IBM 46xx port 5B 01 IBM 46xx port 9B 02 Exit These bar codes to select the IBM USB interface. Start Program Alphanumeric Option Bar Code Option Entry IBM USB 03 Select IBM Interface Exit Product Reference Guide
ページ18に含まれる内容の要旨
IBM Options IBM 46xx Code 39 Conversion This feature enables/disables the scanner’s ability to set the symbology identifier for the specified symbology to Code 39 before sending the label data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM Port 5B; Code 93 and Codabar for IBM Port 9B. This feature is for IBM port 5B and IBM port 9B. NOTES IBM-USB Device Type The IBM-USB protocol allows for the scanner to be identified as one of two different types of barcode scanners.
ページ19に含まれる内容の要旨
Start Program Alphanumeric Option Bar Code Option Entry Disable 00* Enable IBM 46xx Code 39 01 Conversion Table-top 00 Handheld 01* IBM USB Device Type 0x00–0xF6 Max. Host Transmit 00* Message Length Exit IBM Host Commands Specifies whether the scanner will process or ignore IBM host commands. Start Program Alphanumeric Option Bar Code Option Entry Process Host 00* Commands Ignore Host 01 Host Commands Commands Exit Product Reference Guide 15
ページ20に含まれる内容の要旨
Scanning Scanning Mode Good-read off: The trigger button must be pressed to activate scanning. The light source of the QS2500 stops scanning when there is a successful read or no code is decoded after the standby duration has elapsed. Momentary: The trigger button acts as a switch. Pressing the button acti- vates scanning and releasing the button stops scanning. Alternate: The trigger button acts as a toggle switch. Pressing the button activates or stops scanning. Timeout off: The trigger bu