ページ1に含まれる内容の要旨
User’s Manual
LGP Series
Handheld CCD Scanner
25-ULGPMU01-01
April 2002
Keyboard Wedge Interface
USB Interface
RS232 Interface
8 Olympic Drive
Orangeburg, NY 10962
Tel 845.365.0090
Fax 845.365.1251
www.opticonUSA.com
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Table of Contents PART I CCD Scanning Part III Bar Code Menu Functions Section A Programming the Scanner……………….13 General Information ...........................................4 Unpacking Section B Symbology Selections ..................... 14 Factory Technical Support Enabling only a single symbology...................... 14 Enabling additional symbolog
ページ4に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Part I General Information The LGP-6125 Series CCD Scanners utilize state-of-the-art imaging technology similar to that found in digital cameras, facsimile machines and video camcorders. The scanner images the bar code label, then converts the digital signals into data the host computer can understand. By capturing the bar code image all at once, the scanner provi
ページ5に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Part II Installation and SetUp This section of the manual contains information on the physical installation of the scanner as well as certain programming options. There is a separate section for each type of interface. Check to see which type of interface your scanner has and turn to that section for information on installing the scanner A.) Installation – Key
ページ6に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Reset All Defaults – Keyboard Wedge Interface Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most applications, the scanner will work right out of the box without any need for additional programming. At any time you can return the scanner to the factory default settings. First scan the Start
ページ7に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Keyboard Wedge and USB options With Keyboard: Use this mode in case a keyboard is connected to the PC wedge Y-cable. The Wedge is only listening in case the computer is booting or the wedge is idle. Without Keyboard: Use this mode in case no keyboard is connected to the PC wedge Y- cable. In some cases, this mode is required when a PC USB keyboard is connected. If t
ページ8に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Intercharacter Delay for Keyboard Wedge interface The scanner may send data faster than the computer or application program can accept. This is called "keyboard buffer overrun". If data appears to be missing, random read errors occur or the scanner locks up and will not scan, experiment with the various keyboard timing options listed in the menu to follow. Start
ページ9に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner B.) Installation – RS232 Interface The RS-232 scanner cable is terminated in with a DB9 female connector. An external power supply (+5V DC) may be necessary. There is a power supply jack on the RS-232 connector. Installation is as follows: 1. Plug the scanner into an RS232 serial port (such as COM1) of the host PC. If external power is required, insert external
ページ10に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner RS-232C Communication Parameters Handshaking Protocol Start ZZ Program [[ Menu None P0 Q1 RTS/CTS HP04 +IQ15+ ACK/NAK P3 Q! Xon/Xoff ZG [H Flow Control I0 Time J1 Unlimited Flow Control: I1 J2 100ms Flow Control: I2 J3 200ms Flow Control: I3 J! 400ms Baud Rate 19200 K7 L8 9600 K6 L7
ページ11に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Data Bits / Stop Bits / Parity 7 Data Bits L0 M1 8 Data Bits L1 M2 1 Stop Bit L5 M6 2 Stop Bits L6 M7 Even L3 Parity M! Odd L4 Parity M5 Mark L2 No Parity M3 End Program ZZ [[ Menu Page 11
ページ12に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner C.) Installation – USB Interface Plug the scanner into the USB connector on your host computer. PC must be running Windows 98 or higher or iMac Rev A or higher. The computer will sense the presence of the scanner and load any required software drivers automatically. Reset All Defaults - USB Interface Our scanners are shipped with factory default settings tha
ページ13に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Part III Bar Code Menu Functions Section A Programming the Scanner This manual contains information that allows you to easily change certain programmable parameters of the scanner. The scanner is ready to use - no additional programming is required in most situations. The scanner has been programmed at the factory with the most common settings. These factory default
ページ14に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Symbology Selection Start/End Program ZZ [[ Menu Read all codes A0 B1 Code 39 A2 only B3 Codabar A3 only B! IATA only A4 B5 Code 93 A5 only B6 Code 128 A6 only B7 MSI/Plessey A7 only B8 Telepen A9 only B: Matrix 2of5 AB only BC All UPC and J0 EAN only K1 UPC J1 only K2 CONTINUED ON NE
ページ15に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Symbology Selection (continued) Start/End Program ZZ [[ Menu UPC+2 J2 only K3 UPC+5 J3 only K! EAN J4 only K5 EAN+2 J5 only K6 EAN+5 J6 only K7 Industrial 2of5 J7 K8 only Interleaved 2of5 J8 K9 only Trioptics JD only KE These options do not influence the reading of the menu labels. The required bar
ページ16に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Symbology Additions If scanner will not be used to read all symbologies (default setting), speed operation by using this menu to add only the specific symbologies being used (add only the symbologies that are required). Start/End Program ZZ [[ Menu Disable all B0 C1 Enable B2 Code 39 C3 Enable B3 Codabar C! Enable B4 IATA C5 Enab
ページ17に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Symbology Additions (continued) Start/End Program ZZ [[ Menu Enable R4 EAN S5 Enable R5 EAN+2 S6 Enable R6 EAN+5 S7 Enable Industrial R7 S8 2of5 Enable Interleaved R8 S9 2of5 Page 17
ページ18に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner Setting the Number of Characters to be Scanned Start/End Program ZZ [[ Menu Fixed length OFF H0 all codes I1 Fixed length ON H1 I2 all codes Fixed length ON HK selected codes IL Min. length HL selected codes IM Max. length HM selected codes IN Setting Code Specific Options - Options for specific codes may be configured af
ページ19に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner UPC-A/E Settings Options for UPC-A and UPC-E bar codes. NOTE: Abbreviations: Xmit = transmit; CD = Check digit; CC = Country code Start/End Program ZZ [[ Menu UPC-A as EAN13 E2 w/ CD F3 (13 digits) UPC-A w/ CD E3 F! (12 digits) UPC-A w/ CD E4 (12 digits) F5 UPC-A w/o CD E5 F6 (11 digits) UPC-E w/ CC & CD E6 F7
ページ20に含まれる内容の要旨
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner UPC Settings (continued) Options for UPC-A - The UPC-A symbology is a fixed length symbology encoding 11 data digits, a check digit and non printable start/stop characters. Supported characters are numeric digits 1 to 9. An optional leading zero can be transmitted which, together with the data and the check digit, forms a 13 digit field providing compatibility wit