ページ1に含まれる内容の要旨
METROLOGIC INSTRUMENTS, INC.
®
MS2xxx Stratos Series
Configuration Addendum
ページ2に含まれる内容の要旨
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this docume
ページ3に含まれる内容の要旨
TABLE OF CONTENTS Important Notes - Before You Start ...................................................................... 1 Scale Program Mode............................................................................................ 2 Scale/Load Cell Configuration Bar Codes Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms).............................................. 5 Pole Display Configuration...............................................
ページ4に含まれる内容の要旨
TABLE OF CONTENTS IBM Self Checkout System .................................................................. 29 Various RS232 Single Cable Codes .................................................... 30 rd IBM 3 Generation 46xx ...................................................................... 31 IBM OEM Full Speed USB ................................................................... 32 Additional POS Data Formatting Full Speed USB Table Top/Handheld ..............................
ページ5に含まれる内容の要旨
TABLE OF CONTENTS Continuous Mode................................................................................. 71 EAS Deactivation ................................................................................. 72 Sensormatic ScanMax Pro................................................................... 75 Scanner Test Bar Codes Supplemental Tests..................................................................................... 77 Display Software Numbers......................
ページ6に含まれる内容の要旨
IMPORTANT NOTES - BEFORE YOU START It is important to carefully read the notes marked with a symbol on the pages contained in this manual. Not all configuration codes are designed to be used for both a single and dual cable scanner/scale system. Many of the configuration bar codes require additional steps before the unit can be configured and placed into service. Most of the bar codes in this addendum were designed to be used with a Stratos model that includes a scale. The text m
ページ7に含まれる内容の要旨
SCALE PROGRAM MODE The following steps are only required for the scale configuration bar codes located on pages 5 - 19 (bar codes beginning with 996.) 1. Power down the scanner/scale. Then, temporarily remove the scale platter and place it in a safe location. Figure 1. 2. Cut and remove the security seal over the program/calibration switch cover. See Figure 2 below for seal location on the StratosE and the StratosH models. See Figure 3 on page 3 for the seal location on
ページ8に含まれる内容の要旨
SCALE PROGRAM MODE Figure 3. StratosS Calibration Seal and Switch Location 5. Disconnect the scale-to-host RS232 cable from the unit (dual cable interface only.) Figure 4. Disconnect scale-to-host RS232 Cable 6. Reinstall the platter and connect AC power to the scanner. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should be located near the equipment and be easily accessible. Metrologic recommends u
ページ9に含まれる内容の要旨
SCALE PROGRAM MODE 7. If the system is equipped with a remote scale display, it will read H - - -. 8. Use the vertical window to scan the desired scale configuration bar codes, located on pages 5 - 19. Figure 5. 9. Reconnect the scale-to-host RS232 cable to the scanner (dual cable interface only.) Figure 6. 10. The scale must now be calibrated, tested and certified by local Weights and Measures authorities before it can be placed in service. For further details on calibra
ページ10に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms) The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Pounds Set the scale measuring range from 0.00 to 30.00 pounds. ³ 9 9600 1 Scale = Kilograms Set the scale measuring range from 0.000 to 15.000 kilograms. ³ 9 9600 2 5
ページ11に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Pole Display Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale Has Display Set the scale to use a remote display to show all scale activity. A remote display must be plugged into the Scale RS485 to Display connector on the MS2xx0 (see Figure 7) for this feature to
ページ12に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. The scale’s filter setting allows the unit to withstand a certain amount of vibration from the checkout counter. A stronger filter allows for more vibration to be absorbed but the weight may take a little
ページ13に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Medium Filter Medium filter setting for moderate vibration environments. ³ 9 9600 6 Scale = Strong Filter Strong filter setting for high vibration environments. ³ 9 9600 7 8
ページ14に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Single or Dual Cable Scale Configuration Bar Codes Scroll Weight Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. These bar codes only affect the pole display. Scale = Scroll Settling Weight Scroll the weight on the display showing the weight as it changes. ³ 9 9601 0 Scale = Blank Non-Steady Blank the display weight as
ページ15に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Price Computing Configuration The following bar codes are only used when the scale is in Dual Cable mode. The MS2xx0 must be in scale program mode to use these bar codes. * Scale = No Price Computing Scale is not the price computing type. ³ 9 9600 8 * Factory Default Setting Scale = Price Computing Scale is the price computing type. ³ 9 9600 9 10
ページ16に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes. Scale = EPOS Protocol Set the scale RS232 protocol to Serial EPOS. Communication Port Settings: • 2400 Baud • 7 Data Bits ³ 9 9601 3 • 1 Stop Bit •
ページ17に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes. Scale = NCI-ECR Protocol Set the scale RS232 protocol to NCI-ECR. Communication Port Settings: • 9600 Baud • 8 Data Bits • 1 Stop Bit ³ 9 9601 5 • No
ページ18に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes. Scale = EMEA Set the scale to Avery EPOS protocol, kilograms, with a remote display, loose filter, Special Configuration no price computing, and scroll weigh
ページ19に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes. Scale = 2400 Baud Rate Set the scale baud rate for dual
ページ20に含まれる内容の要旨
SCALE/LOAD CELL CONFIGURATION BAR CODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective. The MS2xx0 must be in scale program mode to use these bar codes. Scale = 19200 Baud Rate Set the scale baud rate for dual