TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Before Installing Your MS7600............................................................................. 4 Mounting the MS7600 Series Option A: Shelf Support .................................................................................... 5 Op
ページ4に含まれる内容の要旨
INTRODUCTION ™ The MS7600 Horizon series is Metrologic’s next generation in-counter laser bar code scanner. This compact, hands-free scanner is designed with a dense 20-line omnidirectional scan pattern that helps provide fast, efficient throughput with a high first pass read rate. The MS7600 is equipped with a multitude of standard features including: • Durable die-cast construction • Available with either a stainless steel (MS7625) or a high-impact plastic (MS7620) top plate • Firmware update
ページ5に含まれる内容の要旨
SCANNER AND ACCESSORIES BASIC KIT Part # Description ™ MS7600 Horizon Series Scanner ® 00-02407B MetroSelect Programming Guide 00-02870B MS7600 Horizon Series Installation and User’s Guide 52-52511A 24” EAS cable Guides also available for download at www.metrologic.com. OPTIONAL ACCESSORIES Part # Description 46-46640 Point of Sale (POS) USB Plug Straight PowerLink Cable with built in power jack. 54-54xxx* 2.1 m (7') cord with short strain relief xxx* specifies connection to the host. Contact a
ページ6に含まれる内容の要旨
SCANNER AND ACCESSORIES (CONTINUED) OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer - Regulated 5.2V@650 mA output 45-45593 120V United States 45-45591 220V – 240V Continental European 45-45592 220V – 240V United Kingdom 46-46641 Stainless Steel Trim Ring REPLACEMENT PARTS Part # Description Window types (Sapphire, Everscan, and Standard) are not interchangeable due to laser safety and/or scanner performance differences. Caution To change window type, the scanner must be retur
ページ7に含まれる内容の要旨
BEFORE INSTALLING YOUR MS7600 When mounting the MS7600 or replacing the Top Plate: DO NOT Turn Figure 1 the unit upside down. DO NOT Press Figure 2 on the window. Lift the Top plate straight up to remove. There is no hardware required to remove or replace the top cover. See caution on page 3. There are two installation tabs under the top cover that can be used to place the unit into Figure 3 the counter top mounting hole. DO NOT PRESS on the window in the Figure 4 replacement Top plate. 4
ページ8に含まれる内容の要旨
MOUNTING THE MS7600 SERIES There are three options for mounting your MS7600. Option “A” uses a shelf to support the unit. Option B lets the unit hang free in the counter top. Option C lets the unit hang free in the counter top with the use of a stainless steel trim ring for support. The trim ring (MLPN 46-46641) is an optional purchase. Contact a Metrologic customer service representative for details at 1-800-ID-METRO. Before starting to mount the MS7600, determine the direction of package
ページ9に含まれる内容の要旨
MOUNTING THE MS7600 SERIES OPTION B: Free Hanging Support Figure 8: Package Flow (right) Figure 9: Specifications for free hanging support. Figure 10: Installation Tabs 6
ページ10に含まれる内容の要旨
MOUNTING THE MS7600 SERIES OPTION C: Trim Ring (MLPN 46-46641, Additional Purchase) Figure 11: Counter Top Opening for Trim Ring (MLPN 46-46641) Figure 12: Trim Ring (MLPN 46-46641) Installation 7
ページ11に含まれる内容の要旨
INSTALLATION FOR KEYBOARD WEDGE INTERFACE 1. Turn off the host system. 2. Disconnect the keyboard from the host. 3. Connect the PowerLink cable to the nd 2 jack from the top of the MS7600. 4. Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host. If necessary use the male/female adapter cable supplied with the scanner for proper connections. Before continuing verify that the PowerLink cable is connected to the appropriate interface jack on the scanner. An
ページ12に含まれる内容の要旨
INSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE 1. Turn off the host system. 2. Disconnect the keyboard from the host. nd 3. Connect the PowerLink cable to the 2 jack from the top of the MS7600. 4. Connect the other end of the PowerLink cable to the keyboard port on the host. Before continuing verify that the PowerLink cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. 5. Connect
ページ13に含まれる内容の要旨
INSTALLATION FOR USB INTERFACE 1. Turn off the host system. 2. Determine if your application requires USB Keyboard communication protocols or USB Point of Sale communication protocols. 3. If you require USB Keyboard communication protocols, skip to step 4. Figure 16: POS Plug Installation If you require USB Point of Sale communication protocols: • Remove the MS7600 top cover. • Insert the POS plug (MLPN 46-46640) into the slot indicated in Figure 16. • Replace the top cover. 4. Connect the Powe
ページ14に含まれる内容の要旨
INSTALLATION FOR USB INTERFACE Manufacturers Note: Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur. Enable USB Defaults 6. Scan the Enable USB Defaults bar code to configure the MS7600 for USB communication. ³ 9 99 97 8 7. Turn on the host system. 11
ページ15に含まれる内容の要旨
INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES 1. Turn off the host system. 2. Connect the PowerLink cable into st the 1 jack down from the top of the MS7600. 3. Connect the other end of the PowerLink cable to the host. Before continuing verify that the PowerLink cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. 4. Connect the external power supply to the power jack on the Power
ページ16に含まれる内容の要旨
INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES Step 7, page 12 continued. For RS232 Communication: Recall Defaults st ³9 9 9 9 9 8 Scan 1 Enable RS-232 nd ³4 1 5 5 5 4 Scan 2 For Light Pen Communication: Recall Defaults st ³9 9 9 9 9 8 Scan 1 Enable Light Pen/Wand nd ³4 1 5 5 2 4 Scan 2 13
ページ17に含まれる内容の要旨
INSTALLATION FOR IBM 46XX INTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the st 1 jack down from the top of the MS7600. 3. Connect the other end of the MVC cable to the host. Before continuing verify that the MVC cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. Manufacturers Note: Plugging the scanner into the Figure 19: RS232/IBM, Interface serial port of t
ページ18に含まれる内容の要旨
INSTALLATION FOR OCIA INTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the nd 2 jack down from the top of the MS7600. 3. Connect the other end of the MVC cable to the host. Before continuing verify that the MVC cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. Manufacturers Note: Plugging the scanner into the Figure 13: OCIA, Interface serial port of the PC doe
ページ19に含まれる内容の要旨
INSTALLATION OF A SECONDARY SCANNER 1. Turn off the host system. 2. Connect the round end of the PowerLink RS232 AUX cable [MLPN 54-54667A] to the RS232 jack of the secondary scanner (see figure 20). rd 3. Connect the other end of the PowerLink RS232 AUX cable into the 3 jack down from the top of the MS7600. The following Metrologic scanners can be used in the “Aux” input of the MS7600: the MS9520, MS9540, MS7220, MS7120, MS6720, MS6220, MS6520, MS5145 or another MS7600. Important: The MS7600 au
ページ20に含まれる内容の要旨
INSTALLATION OF A SECONDARY SCANNER 11. Scan the following bar code to configure the auxiliary port on the MS7600 to accept a Metrologic scanner as the secondary scanner. The following bar codes do not apply when using an MS6720 as a secondary scanner. Contact a Metrologic representative for additional information on the MS6720. If the secondary scanner is not a Metrologic scanner refer to Section O of the MetroSelect Configuration Guide. Enable Aux Port ³ 4 3 733 0 The auxiliary input port’s