ページ1に含まれる内容の要旨
MS5100
Eclipse™ Series
Installation and User’s Guide
ページ2に含まれる内容の要旨
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII. HII shall not be liable for technical or editorial errors or omissions contained herein: nor for incidental or
ページ3に含まれる内容の要旨
TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 Maintenance..................................................................................................... 4 Caution and Serial N
ページ4に含まれる内容の要旨
TABLE OF CONTENTS Regulatory Compliance Safety ............................................................................................................. 37 EMC ............................................................................................................... 38 Limited Warranty ................................................................................................ 40 Patents ......................................................................................
ページ5に含まれる内容の要旨
INTRODUCTION The MS5145 Eclipse ™ is a single-line, hand-held laser scanner. ® Equipped with Honeywell’s patented CodeGate technology, Eclipse can be used in a wide variety of applications. CodeGate technology allows the user to easily target the desired bar code and complete the data transmission with a simple press of a button. This combination makes Eclipse a perfect selection for menu scanning, point-of-sale, document processing and inventory control. With state-of-the-a
ページ6に含まれる内容の要旨
INTRODUCTION Scanner and Accessories BASIC KIT Part # Description MS5145 Eclipse Scanner * 00-02544 MetroSelect Single-Line Configuration Guide * 70-79016 MS5100 Eclipse Series Installation and User’s Guide *Available for download from www.honeywell.com/aidc OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer- Regulated 5.2VDC @ 1A output. 46-00525 90VAC to 255VAC, United States, Canada and Japan 46-00526 90VAC to 255VAC, Continental European 46-00527 90V
ページ7に含まれる内容の要旨
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part # Description RS232 PowerLink Cable with Built in Power Jack 55-55000x-3 straight cord, long strain relief, black Keyboard Wedge PowerLink Cable with Adapter 55-55002x-3 straight cord, long strain relief, black Stand Alone Keyboard PowerLink Cable, 55-55020x-3 straight cord, long strain relief, black USB Low Speed Communication Cable, Type A 55-55235x-N-3 straight cord, long strain relief, black USB Full Speed
ページ8に含まれる内容の要旨
INTRODUCTION Scanner Components ITEM NO. DESCRIPTION 1 Mode Select Button/CodeGate Button (see page 12) 2 Red LED (see page 14) 3 Green LED (see page 14) 4 Pin Hole for Cable Release (see page 6) 5 Red Output Window (Laser Aperture) 6 Speaker (see page 13) 7 10-Pin RJ45, Female Socket (see page 33) Figure 1. Scanner Components Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the window requires cleaning, use only a mil
ページ9に含まれる内容の要旨
INTRODUCTION Caution and Serial Number Labels Figure 2. Label Location on the Bottom of the Scanner with Example Caution To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited
ページ10に含まれる内容の要旨
INTRODUCTION Cable Removal Disconnect the power supply from the PowerLink cable and turn off power to the host system before removing the cable from the scanner. 1. Locate the small ‘pin-hole’ on the front side of the scanner near the end of the handle. 2. Bend an ordinary paperclip into the shape shown. 3. Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’. There will be a faint ‘click’ when the connector’s lock releases. 4. Pull gently on the c
ページ11に含まれる内容の要旨
INSTALLATION RS232, Light Pen or Laser Emulation 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Connect the 9-pin female end of the PowerLink cable to the appropriate communication port on the host device. 4. Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
ページ12に含まれる内容の要旨
INSTALLATION RS485 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS5145. 3. Connect the other end of the MVC cable to Port 9 of the host device. 4. Turn on the host device Figure 7. RS485 (above) Connections See page 5. ® Applicable for IBM Host applications. 8
ページ13に含まれる内容の要旨
INSTALLATION Keyboard Wedge 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Disconnect the keyboard from the host/PC. 4. Connect the Y ends of the PowerLink cable to the keyboard and the host’s keyboard port. If necessary, use the supplied adapter cable to make the connections. 5. Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of th
ページ14に含まれる内容の要旨
INSTALLATION Stand-Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Eclipse. There will be a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. Make sure the AC input requirements of the power supply match the AC outlet. Connect the power supply into an AC
ページ15に含まれる内容の要旨
INSTALLATION USB: Low Speed USB (-38) Full Speed USB (-40) 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector of the USB cable into the jack on the Eclipse. There will be a ‘click’ when the connection is made. 3. Connect the other end of the USB cable to the host USB port. 4. Turn on the host system. Figure 10. USB As a default, the MS5145-38 leaves the factory with USB Keyboard Emulation Mode enabled. For information on configuring the
ページ16に含まれる内容の要旨
SCANNER OPERATION How to Use CodeGate and the Manual Activation Mode ® CODEGATE MANUAL ACTIVATION MODE* * This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode. Figure 11. CodeGate Enabled Figure 12. Manual Activation Mode Two Modes of Operation CodeGate, Out-of-Stand • CodeGate activates when removed from the stand • Bar code data is transmitted when the button is pressed Manu
ページ17に含まれる内容の要旨
SCANNER OPERATION Indicators Audible When the MS5145 scanner is operational, the scanner provides audible feedback to indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instructions on how to change the tone of the beeper, refer to the Single-Line MetroSelect Configuration Guide. One Beep – On Power Up The green LED will turn on, then the red LED will flash and the
ページ18に含まれる内容の要旨
SCANNER OPERATION Indicators Visual The MS5145 is equipped with a red LED and green LED which indicate the scanner’s state and the status of the current scan when the unit is in operation. Figure 13. LED Color and Location Green and Red LEDs Are Off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Green Indicates normal pulse or continuous laser operation. Accompanied by a razzberry tone, it indicates that
ページ19に含まれる内容の要旨
SCANNER OPERATION Indicators Failure One Razzberry Tone – On Power Up This indicates the scanner has experienced a laser or flipper subsystem failure. Return the unit for repair to an Authorized Service Center. Continuous Razzberry Tone with no LEDs If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure. Return the unit for repair to an Authorized Service Center. Three Beeps – On Power Up If the s
ページ20に含まれる内容の要旨
SCANNER OPERATION Depth of Field vs. Minimum Bar Code Element Width Minimum Bar Code Element Width A B C D E F mm .10 .12 .17 .26 .33 .66 mils 4.1 4.8 6.8 10.4 13 26 Figure 14. Depth of Field vs. Minimum Bar Code Element Width 16