ページ1に含まれる内容の要旨
INST ALLA TION
FT106011/FR106011
Fiber Transmitter
and Receiver
Video with Bidirectional Audio, Data,
and Contact Closure
C2649M (9/07)
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ページ4に含まれる内容の要旨
List of Tables A Audio Select Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 B Data Select Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 C Contact Closure Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 D Data Connector Pin Assignments. . . . . . . . . . . . . . .
ページ5に含まれる内容の要旨
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the po
ページ6に含まれる内容の要旨
The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present CAUTION: within this unit. RISK OF ELECTRIC SHOCK. This symbol indicates that there are important DO NOT OPEN. operating and maintenance instructions in the literature accompanying this unit. 6 C2649M (9/07)
ページ7に含まれる内容の要旨
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provi
ページ8に含まれる内容の要旨
Product Overview DESCRIPTION The FT106011/FR106011 fiber transmitter and receiver provide simultaneous transmission of one unidirectional video channel, two bidirectional audio channels, one bidirectional data channel, and one bidirectional contact closure over one optical fiber (refer to Figure 1). VIDEO VIDEO AUDIO FT106011 FR106011 AUDIO TRANSMITTER RECEIVER DATA ONE DATA CONTACT FIBER CONTACT CLOSURE CLOSURE Figure 1. FT106011/FR106011 Video, Audio, Data, and Contact Closure Transmissio
ページ9に含まれる内容の要旨
MODELS The FT106011/FR106011 fiber transmitter and receiver consist of the following series of models: Multimode Models:* FT106011MSTR Fiber optic video transmitter with two bidirectional audio channels, one bidirectional data channel, and one bidirectional contact closure; multimode, ST connector FR106011MSTR Fiber optic video receiver with two bidirectional audio channels, one bidirectional data channel, and one bidirectional contact closure; multimode, ST connector Single-Mode Models:* FT
ページ10に含まれる内容の要旨
FRONT PANEL The front panel of the FT106011 transmitter and FR106011 receiver provides LED indicators that allow you to monitor contact closure activation, audio signal status, data activity, video signal status, optical signal/laser status, and operating power (refer to Figure 2). FT106011 FR106011 TRANSMITTER RECEIVER Figure 2. Front Panel of FT106011 Transmitter and FR106011 Receiver CONTACT CLOSURE LED AUDIO PRESENT LED DATA ACTIVITY LED VIDEO PRESENT LED OPTIC FAULT LED (optical signal
ページ11に含まれる内容の要旨
REAR PANEL All connections to the FT106011 transmitter and FR106011 receiver are made to the rear panel of the modules (refer to Figure 3). Figure 3. Rear Panel of FT106011 Transmitter and FR106011 Receiver RACK POWER/ALARM CONNECTOR, 4-pin connector for power/alarm connection of rack- mounted module STAND-ALONE POWER CONNECTOR, 2-pin connector for power connection of stand-alone module; removable mating connector with screw terminals (not shown) FIBER OPTIC CONNECTOR, ST or FC (dependent on
ページ12に含まれる内容の要旨
Installation PACKAGE CONTENTS The following items are supplied: 1 FT106011 transmitter or FR106011 receiver 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output 1 1 small flat-tip screwdriver 1 Wall clip with two 4-40 x 0.25-inch Phillips pan head screws with lock washers (for attachment of single module to wall) 1 FT106011/FR106011 Fiber Transmitter and Receiver Installation manua
ページ13に含まれる内容の要旨
AUDIO SELECT SWITCH AUDIO DATA SELECT SELECT 0. UNBAL 47K 0. RS-232 1. BAL 600 1. RS-422 2-9 NOT USED 2. RS-485 2W 3. RS-485 4W 4. Man/Bi-Phase 5. Coaxitron 6-9 NOT USED Figure 4. Audio Select Switch Table A. Audio Select Switch Settings Switch Setting Audio Mode 0 (default setting) UNBAL 47K Ω: Unbalanced audio signals, 47K-ohm input impedance BAL 600 Ω: Balanced audio signals, 600-ohm input 1 impedance NOTE: Switch settings 2-9 are not used. If switch setting 2-9 is selected, the Audio Pr
ページ14に含まれる内容の要旨
SETTING THE DATA COMMUNICATION MODE A Data Select switch, which is a 10-position rotary switch, is provided on the bottom of the FT106011 transmitter and the FR106011 receiver (refer to Figure 5). The Data Select switch allows you to set the data communication mode required for the transfer of data. With the FT106011 transmitter/FR106011 receiver powered off, set the Data Select switch to the required data communication mode using the supplied screwdriver. Table B lists Data Mode Select swi
ページ15に含まれる内容の要旨
DATA SELECT SWITCH AUDIO DATA SELECT SELECT 0. UNBAL 47K 0. RS-232 1. BAL 600 1. RS-422 2-9 NOT USED 2. RS-485 2W 3. RS-485 4W 4. Man/Bi-Phase 5. Coaxitron 6-9 NOT USED Figure 5. Data Select Switch Table B. Data Select Switch Settings Switch Setting Data Communication Mode 0 (default setting) RS-232 1 RS-422 2 RS-485 2-Wire 3 RS-485 4-Wire 4 Manchester/Bi-Phase 5 Coaxitron NOTE: Switch settings 6-9 are not used. If switch setting 6-9 is selected, the Data Activity LED lights red. C2649M (9/07
ページ16に含まれる内容の要旨
MOUNTING THE TRANSMITTER/RECEIVER The FT106011 transmitter/FR106011 receiver can be mounted into a rack or can be used as a stand- alone module. As a stand-alone module, the unit can be placed on a desktop or can be mounted to a wall. MOUNTING THE TRANSMITTER/RECEIVER INTO A RACK The FT106011 transmitter/FR106011 receiver can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount c
ページ17に含まれる内容の要旨
Mounting the Transmitter/Receiver Using the Wall Clip NOTE: Before mounting the FT106011 transmitter/FR106011 receiver to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for making the various rear-panel cable connections. To attach the FT106011 transmitter/FR106011 receiver to a wall using the supplied wall clip, refer to Figure 6 and do the following: 1. Using the two vertical or horizontal wall-mounting holes, attach the wall clip to a wall usi
ページ18に含まれる内容の要旨
CONNECTING THE TRANSMITTER/RECEIVER Connections to the FT106011 transmitter and the FR106011 receiver are made on the rear panel of the modules (refer to Figure 7) and consist of the following: • Power connection NOTES: – A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when used as a stand-alone module. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 2
ページ19に含まれる内容の要旨
POWER/ALARM CONNECTION FOR RACK-MOUNTED MODULE POWER CONNECTION FOR STANDALONE MODULE FIBER OPTIC CABLE CONTACT CLOSURE, DATA, AND AUDIO COMMUNICATIONS CABLES (REFER TO TABLES C, D, AND E FOR CONNECTOR PIN ASSIGNMENTS AND TO FIGURES 8-17 FOR WIRING DIAGRAMS) COAXIAL CABLE TO INSERT OR REMOVE A WIRE, PIN 2 DO THE FOLLOWING: PIN 1 1. USING THE SUPPLIED SCREWDRIVER, PRESS DOWN ON THE APPROPRIATE CLAMP UNTIL THE SCREWDRIVER IS FIRMLY SEATED IN THE SLOT. 2. INS
ページ20に含まれる内容の要旨
Table D. Data Connector Pin Assignments Pin RS-485 RS-485 Number RS-232 RS-422 2-Wire 4-Wire Manchester Bi-Phase 1 TX+ (Out+) T+/R+ (Out+/In+) TX+ (Out+) TX+ (Out+) (W) TX+ (Out+) 2 TX-(Out-) T-/R-(Out-/In-) TX- (Out-) TX- (Out-) (B) TX- (Out-) 3 — RX+ (In+) — RX+ (In+) RX+ (In+) (W) RX+ (In+) 4 — RX- (In-) — RX- (In-) RX- (In-) (B) RX- (In-) 5RX (In) — — — — — 6TX (Out) — — — — — 7 or 8 Ground —* —* —* Shield Shield *Ground may be required based on conditions of installation. Refer to the