Installation Gas Slide-In Range
Instructions JGSP28
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.GEAppliances.com
IN THE COMMONWEALTH OF PARTS INCLUDED
MASSACHUSETTS:
• This product must be installed by a
licensed plumber or gas fitter.
• When using ball-type gas shut-off valves,
Screws Anti-Tip Bracket
they shall be the T-handle type.
Rear Filler
2 Screws
• A flexible gas connector, when used, must
not exceed 3 feet.
MATERIALS YOU MAY NEED
BEFORE YOU BEGIN
Read thes
ページ2に含まれる内容の要旨
Installation Instructions IMPORTANT SAFETY INSTRUCTIONS This range has been design certified by FOR YOUR SAFETY: UNDERWRITERS LABORATORIES. You’ll find safety precautions in your Owner’s Manual. WARNING — If the information Read them carefully. in this manual is not followed exactly, a fire, explosion or gas leak may result, causing • Installation of this range must conform with property damage, personal injury or death. local codes or in the absence of local codes with the National Fuel Gas Co
ページ3に含まれる内容の要旨
Installation Instructions ELECTRICAL REQUIRMENTS ANTI-TIP DEVICE This appliance must be supplied with the WARNING — To reduce the risk proper voltage and frequency and connected of tipping, the appliance must be secured to an individual, properly grounded branch by properly installed Anti-Tip bracket packed circuit, protected by a circuit breaker or fuse with this appliance. having amperage as noted on the rating plate. (Rating plate is located above the To check if the bracket is installed an
ページ4に含まれる内容の要旨
Installation Instructions PRE-INSTALLATION CHECKLIST 1 INSPECT INSTALLATION 2 MOVE RANGE INDOORS IN LOCATION FRONT OF CABINET OPENING Refer to alternate construction section for Do not use hand trucks when moving the the following non-standard installations. unpackaged range. Cooktop enamel may be chipped. Counter opening extends to the wall: A Maintop Filler (supplied with the range) (see page 15 for Installation Instructions) or Backguard Kit (JXS32XX). 3 PROTECT THE KITCHEN Counter height gr
ページ5に含まれる内容の要旨
Installation Instructions 5 REMOVE THE DOOR IF 5 REMOVE THE DOOR IF NECESSARY NECESSARY (cont.) Door removal is not a requirement for C LIFT OFF DOOR installation of the product, but is an added Lift door up and out until the hinge arms convenience. To remove the door: clear the slots. DO NOT LIFT THE DOOR BY THE HANDLE. A UNLOCK HINGES NOTE: The oven door is very heavy. Be sure Push both hinge locks down toward the you have a firm grip before lifting the oven door frame, to the unlocked positi
ページ6に含まれる内容の要旨
Installation Instructions PRE-INSTALLATION CHECKLIST (CONT.) 8 PRE-INSTALLATION CUTOUT AND REQUIRED CLEARANCES If cabinets are placed less than 30″ above the range, see Alternate Construction, Step 19F, on page 16. NOTE: Product meets ANSI Z21.1 requirements for 0″ clearance to back and side walls below the cooktop. Wall coverings, counters and cabinets around range must withstand heat (up to 194°F) generated by the range. Follow instructions packaged with 30” min. alternate appliance 6” min.
ページ7に含まれる内容の要旨
Installation Instructions ELECTRICAL CONNECTIONS 10 INSTALLATION—ELECTRICAL CONNECTIONS A Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it is a UL listed 3-wire grounding-type appliance extension cord and that the current carrying rating of the cord in amperes is equivalent to or greater than the branch circuit rating. Such extension co
ページ8に含まれる内容の要旨
Installation Instructions GAS CONNECTIONS 11 MAKING THE CONNECTIONS 11 MAKING THE CONNECTIONS (cont.) F Install 1/2″ flare union adaptor to the 1/2″ NPT elbow on pressure regulator. 3″ 7″ Connect flexible appliance connector to G 15″ 1 flare union. 3 ⁄2″ 12″ Move range into approximate position H and connect flexible connector to gas supply line with proper flare union A Install a manual shut-off valve in the gas supply line in an easily accessible location. adaptor. Know how and where to shut
ページ9に含まれる内容の要旨
Installation Instructions INSTALL THE RANGE 12 INSTALL THE ANTI-TIP BRACKET 12 INSTALL THE ANTI-TIP BRACKET (cont.) A LOCATE THE BRACKET a. Decide whether the bracket will be B INSTALL THE BRACKET IN WOOD installed on the right or left side of the OR CONCRETE range opening. b.Place the bracket as shown in Fig. 1. INSTALLATION—WOOD CONSTRUCTIONS a. Locate the centers of the 4 holes identified in Fig. 1 as Floor–Wood and Wall. Fig. 1 b. Drill a 1/8″ pilot hole through the pre-marked areas. Note
ページ10に含まれる内容の要旨
Installation Instructions INSTALL THE RANGE (CONT.) 13 SLIDE RANGE INTO OPENING 13 SLIDE RANGE INTO OPENING (cont.) A Position the range in front of the cabinet opening. H Plug the range cord into the receptacle. Locate the cord in the back of the range Make sure that the cooktop edges that B in a manner that it will not touch or be overhang the countertop clear the moved by the drawer. countertop. If necessary, raise the unit by lowering the leveling legs. Position range cord Push while lifti
ページ11に含まれる内容の要旨
Installation Instructions 15 REPLACE THE OVEN DOOR 16 REPLACE THE STORAGE DRAWER NOTE: The oven door is heavy. You may need help lifting the door high enough to slide it A Place the drawer rail on the guides. into the hinge slots. Do not lift the door by Push the drawer in until it stops. B the handle. Lift the front of the drawer and push C Lift the oven door by placing one hand on A in until the stops clear the guides. each side. The door is heavy, so you may Lower the front of the drawer
ページ12に含まれる内容の要旨
Installation Instructions INSTALL THE RANGE (CONT.) 17 COOKTOP BURNERS 17 COOKTOP BURNERS (cont.) A ASSEMBLE THE BURNERS A ASSEMBLE THE BURNERS (cont.) c. Place the matching size caps onto the heads. Make sure that the heads and caps are CAUTION: The electrode of the spark igniter is exposed. Be careful not to placed in the correct locations. snag the electrode of the spark igniter with Place the vent grille, grates and air inlet a cleaning cloth. Damage to the igniter could cover onto the cook
ページ13に含まれる内容の要旨
Installation Instructions C PRESSURE TEST INFORMATION E BURNER IGNITION The maximum allowable supply pressure for Cooktop Spark Ignition—When you turn the regulator is 14″ W.C. The minimum supply the cooktop knob to LITE, the spark igniter pressure needed to check the regulator setting makes a series of electric sparks (ticking is 7″ W.C. for natural gas and 10″ W.C. for LP gas. sounds) which light the burner. During a power failure the burners will not light automatically. In an emergency, a c
ページ14に含まれる内容の要旨
Installation Instructions INSTALL THE RANGE (CONT.) B ADJUST THE AIR SHUTTER 18 BAKE AND BROIL BURNERS BAKE BURNER If the bake and/or broil burners have lifting or “lazy” (floating) flames or you have a yellow 1. Remove the orifice fitting cover. flame, perform the following procedures: 2. Use a screwdriver to loosen the air shutter screw. A CHECKING THE OVEN BURNERS 3. Adjust the air shutter to 11/32″. To check the bake burner flames with the oven door in the closed position: 4. Retighten the a
ページ15に含まれる内容の要旨
Installation Instructions When the trim is set in the proper position, 19 ALTERNATE CONSTRUCTION tighten the 2 mounting screws. The top of PREPARATION the trim should be located below the cooktop edge to prevent pots, pans and skillets from A OPTIONAL MAINTOP FILLER OR damaging the painted parts. BACKGUARD KIT Refer to the Standard Installation of the If counter opening extends to the wall, it will Range on page 6. require Maintop Filler Kit (supplied with the range) or Backguard Kit (JXS32XX)
ページ16に含まれる内容の要旨
Installation Instructions INSTALL THE RANGE (CONT.) Please see L.P. conversion instructions 19 ALTERNATE CONSTRUCTION supplied with this range when L.P. Gas PREPARATION (cont.) is used. D FOR CABINET OPENINGS NOTE: Instructions are mounted on APPROXIMATELY 30-3/8″ regulator bracket. If range is installed in cabinet opening approximately 30-3/8″, the Vertical Side Trim Kit (JXS86XX) should be used to cover gaps between range sides and cabinet. Refer to the kit IN SOME CASES instructions for inst