ページ1に含まれる内容の要旨
You can rely on
User Guide and Gold HE A
Important Warranty Information Range
Condensing
Combination Boiler
Please keep these instructions in a safe place.
If you move house, please hand them over to
the next occupier.
© Baxi Heating UK Ltd 2012
ページ2に含まれる内容の要旨
Natural Gas Contents Potterton Gold Combi 24 HE A o G.C.N 47 393 18 Section Page Potterton Gold Combi 28 HE A o G.C.N 47 393 19 1.0 Quick Reference Guide 3 Potterton Gold Combi 33 HE A o G.C.N 47 393 20 2.0 Troubleshooting 4 3.0 Repressurising System 6 4.0 Clearances 7 5.0 Care of the Boiler 8 6.0 Legislation 9 7.0 Setting the Timer 10 8.0 Emergency 11 9.0 Warranty & Service 12 The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standar
ページ3に含まれる内容の要旨
2 3 4 5 AM 7 8 9 10 11 12 1 1.0 Quick Reference Guide 2 Reset 1 3 0 4 0 bar ON/OFF/Reset Display Central Heating Domestic Hot Water System Pressure Gauge Integral Timer Selector Switch Temperature Control Temperature Control Reset Reset Reset Reset OFF Position Central Heating & Hot Water Domestic Hot Water Reset The boiler will not operate. Both Heating & Hot Water will operate. Hot Water will operate. Hold for approx 5 seconds and release. Central Heating Indicator - The indicator will illumin
ページ4に含まれる内容の要旨
Boiler not working 2.0 Troubleshooting START Make sure the gas supply is Is the ( ) or ( ) light on YES YES NO Is the ON/OFF/Reset turned ON and check if other and the ( ) on ? Select Switch in the gas appliances are operating ( ) position and (e.g. fire, cooker). Central Heating the display lit ? Domestic Hot Indicator Water Indicator NO If no gas, consult your supplier. Reset Burner On Indicator YES Display NO Boiler operating satisfactorily. Check electricity to the bo
ページ5に含まれる内容の要旨
2 3 4 5 AM 7 8 9 25 25 10 11 20 20 12 1 2.0 Troubleshooting Is the Integral Timer ON Is the Room Thermostat (if YES YES and calling for heat ? fitted) set high enough ? 15 0 NO Turn Room Thermostat to NO maximum setting (typical example shown). Ensure timer is set for Central Heating ON (see Section 7.0 of these instructions - ‘Setting the 15 Timer’) CONTACT YOUR INSTALLER OR SERVICE ENGINEER. If you don’t know what you need to do to get the boiler to light, or need help with the system and cont
ページ6に含まれる内容の要旨
3.0 Repressurising the System 3.1 Central Heating System Pressure 1. The water pressure in the central heating system is indicated by the pressure gauge. 2 1 3 2. With the system cold and the boiler not operating the pressure should be at least 0.5 bar. During operation the Fig. 1 0 4 pressure should not exceed 2.5 bar, and will normally be bar between 1.0 and 2.0 (Fig. 1). 2 Normal Pressure 3. A pressure of 3 or greater indicates a fault. The safety 1 3 pressure relief valve will operate, at a
ページ7に含まれる内容の要旨
4.0 Clearances 4.1 For your Safety 5mm Min 450mm 5mm Min 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 200mm Min (300mm Min if 2. Any modification that may interfere with the normal using 80/125mm flueing system) operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Re
ページ8に含まれる内容の要旨
2 3 4 5 AM 7 8 9 10 11 12 1 5.0 Care of the Boiler 5.1 Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 5.2 Protection & Precaution 1. The boiler incorporates an integral frost protection feature that will operate in both modes. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised. 2. If a system frost thermostat has been fitted (your install
ページ9に含まれる内容の要旨
6.0 Legislation 6.1 Installation, Commissioning, Service & Repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3. Definition of competence: A person who works for a Gas Safe registered company and holding current certificates in the relevant
ページ10に含まれる内容の要旨
2 2 3 3 4 4 5 5 AM AM 7 7 8 8 9 9 9 10 10 10 11 11 12 12 1 7.0 Setting the Timer 7.1 Setting the Timer Time Pointer The Electro-Mechanical Timer allows the central heating system to be set every 15 minutes. Constant Using the three position switch the timer will allow either constant operation, timed operation or central heating off. Timed Move the switch button by sliding to the desired position. Off Three position switch (Fig. 6) 0 Constant (Top position): The heating will be on constantly i
ページ11に含まれる内容の要旨
8.0 Emergency Warning ! If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and vacate the premises Telephone the National Gas Emergency Service on:- 0800 111 999 Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until th
ページ12に含まれる内容の要旨
Please complete the boxes below 9.0 Warranty & Service Serial Number Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 731 1644. It is also a requirement of the warranty that the boiler has an annual service (every 12 months) in accordance with the installation and servicing