ページ1に含まれる内容の要旨
246815-YTG-D-0108
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
TECHN
ページ2に含まれる内容の要旨
246815-YTG-D-0108 22-3/4 7/8 A T-STAT WIRING 7/8” K.O. 7/8 T-STAT WIRING 7/8” K.O. HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” 13-7/8 HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” HORIZONTAL CONDENSATE 40 HORIZONTAL DRAIN OPENING 2” CONDENSATE DRAIN OPENING 1-3/4” JUNCTION BOX 29 29 HOLE 7/8” JUNCTION BOX 22-3/4 22-3/4 HOLE 7/8” GAS PIPE ENTRY 1-1/2” 21-5/8 21-1/4 GAS PIPE CONDENSATE DRAIN 18-1/2 18-1/2 ENTRY 1-1/2” HOLE 7/8” 11-3/4 SIDE PIPING HOLE 3-3/8” 9-1/8 7-1/2 CONDENSATE DRAIN 8-1/2 HOLE 7/
ページ3に含まれる内容の要旨
246815-YTG-D-0108 AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM PC9B12N060DH11 PC9B12N080DH11 JUMPER SETTINGS CFM CFM High Low High Low COOL Tap ADJ Tap 1330 900 1310 890 A B 1130 800 1100 740 B B 1220 850 1220 830 A A 1040 730 1000 670 B A 1120 770 1090 720 A C 920 650 900 610 C B 950 660 880 610 B C 740 540 680 510 D B 860 610 810 580 C A 690 540 630 500 D A 790 570 730 530 C C 630 530 590 500 D C PC9C16N080DH11 PC9C20N100DH11 PC9C16N100DH11 JUMPER SETTINGS CFM CFM High Low High Low
ページ4に含まれる内容の要旨
246815-YTG-D-0108 FILTER PERFORMANCE FILTER SIZES The airflow capacity data published in the “Blower Perfor- Cabinet Top Return mance” table listed above represents blower performance CFM Size Filter in WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- 1200 B (2) 14 x 20 ter being used or select an appropriate value from the “Filter 1600 C (2) 14 x 20 Performance” table shown. 2000 C (2) 14 x 20 NOTE: The filter pressure
ページ5に含まれる内容の要旨
246815-YTG-D-0108 For additional connection diagrams for all UPG equipment refer to “Line Voltage System Wiring” document available on-line at www.upgnet.com in the Product Catalog Section. AC 26A Two Stage Air Conditioner – Variable Speed Modulating Furnace ID MODELS PC9 FC9C FL9C THERMOSTAT THERMOSTAT VARIABLE SPEED TWO STAGE *DN22U00124 *PP32U70124 MODULATING AIR FURNACE CONDITIONER VARIABLE SPEED 1 MODULATING FURNACE CONTROL C C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Vo
ページ6に含まれる内容の要旨
246815-YTG-D-0108 AC 26B Two Stage Air Conditioner – Variable Speed Modulating Furnace ID MODELS PC9 FC9C FL9C THERMOSTAT THERMOSTAT VARIABLE SPEED TWO STAGE *DN22C00124 *DP22U70124 MODULATING AIR FURNACE CONDITIONER VARIABLE SPEED 1 MODULATING FURNACE CONTROL C C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common Y Y1 Y1 Y1 First Stage Compressor First Stage Compressor Single Stage Compressor First Stage Compressor R R R R 24 – Volt Hot 24 – Volt Hot 24 – Volt Hot 24 – Vol
ページ7に含まれる内容の要旨
246815-YTG-D-0108 AC 26C Two Stage Air Conditioner – Variable Speed Modulating Furnace ID MODELS PC9 FC9C FL9C THERMOSTAT VARIABLE SPEED TWO STAGE *PP32U71124 MODULATING AIR *PP32U72124 FURNACE CONDITIONER VARIABLE SPEED 1 MODULATING FURNACE CONTROL C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common Y1 Y1 Y1 First Stage Compressor Single Stage Compressor First Stage Compressor R R R 24 – Volt Hot 24 – Volt Hot 24 – Volt Hot G G Comfort Alert Interface Fan Fan (two pin connector) E/W1 W Fi
ページ8に含まれる内容の要旨
246815-YTG-D-0108 HP 28A Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation) ID MODELS OD MODELS PC9 YZE FC9C YZH FL9C H*5 THERMOSTAT H*8 VARIABLE SPEED TWO STAGE *PP32U71124 MODULATING HEAT PUMP *PP32U72124 FURNACE VARIABLE SPEED 2 YORKGUARD VI 1 MODULATING CONTROL FURNACE CONTROL C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common Y1 Y1 Y1 First Stage Compressor Single Stage Compressor Single Stage Compressor R R R 24 – Volt Hot 24 – Volt Hot 24 –
ページ9に含まれる内容の要旨
246815-YTG-D-0108 HP 28C Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation) ID MODELS OD MODELS PC9 YZE FC9C YZH FL9C H*5 THERMOSTAT THERMOSTAT H*8 VARIABLE SPEED *DN22H00124 TWO STAGE *PP32U70124 MODULATING *DP22U70124 HEAT PUMP FURNACE VARIABLE SPEED 2 YORKGUARD VI 1 MODULATING CONTROL FURNACE CONTROL C C C C 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common Y Y1 Y1 Y1 First Stage Compressor First Stage Compressor Single Stage Compressor S
ページ10に含まれる内容の要旨
246815-YTG-D-0108 COMBUSTIBLE FLOOR BASE - ACCESSORIES 1CB0317 - 17 1/2” Cabinet PROPANE (LP) CONVERSION KIT - 1CB0321 - 21” Cabinet 1NP0680 - All units 1CB0324 - 24-1/2” Cabinet This accessory conversion kit may be used to convert natural COIL TRANSITION - gas (N) units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel. 1TK0917 - 17 1/2” Cabinet 1TK0921 - 21” Cabinet CONCENTRIC VENT TERMINATION - 1TK0924 - 24-1/2” Cabinet 1CT0302 (2") Required
ページ11に含まれる内容の要旨
246815-YTG-D-0108 NOTES Unitary Products Group 11
ページ12に含まれる内容の要旨
NOTES Subject to change without notice. Printed in U.S.A. 246815-YTG-D-0108 Copyright © by Unitary Products Group. 2008. All rights reserved. Supersedes: 246815-YTG-C-0606 Unitary 5005 Norman Products York OK Group Drive 73069