button. 3 You can select the sub-menu item. Unavailable items on the menu screen are grayed out and cannot be selected. 5
ページ6に含まれる内容の要旨
NETWORK menu (continued) Projector name You can change the projector name to be displayed on the network. Press ▲▼ to select [Projector name], and press button. 1 PT-EX16K Projector name Select characters with the ▲▼◄► buttons 2 and press the button to enter the projector name. Select [SET] with the ▲▼◄► buttons and press 3 the button. Select [CANCEL] to undo the changes and then press the button. Select [YES] or [No] with the ▲
ページ7に含まれる内容の要旨
NETWORK menu (continued) Network setup You can make detailed wired LAN settings. Press ▲▼ to select [Network setup], and press button. 1 The detailed [Network setup] screen will be displayed. Press ▲▼ to select an item, and change the setting according to the instructions. 2 On: If a DHCP server exists in the network to which the projector is connected, the IP address will automatically be acquired. DHCP (DHCP client function) Off: If a DHCP server does not exist in the network t
ページ8に含まれる内容の要旨
NETWORK menu (continued) Network control Set when you want to control the projector from a computer connected to the network. Press ▲▼ to select [Network control]. 1 Press button or the ► button to access the submenu. 2 Select [WEB control], [PJLink control], [Command control], [AMX D.D.] items with the ▲▼ buttons. For more details about AMX D.D., visit http://www.amx.com/. 8
ページ9に含まれる内容の要旨
NETWORK menu (continued) Network status This function shows the LAN setting environment of the currently selected projector. Press ▲▼ to select [Network status]. 1 Press button or the ► button to show the information of the current 2 projector status. 9
ページ10に含まれる内容の要旨
NETWORK menu (continued) Network factory default You can reset the network setting to the factory default of the projector. Press ▲▼ to select [Network factory default], and press button. 1 A confirmation box appears and select [Yes] and then press button. Another 2 confirmation box appears and select [Yes] and then press button. Connecting with Wired LAN Computer operation Connection can be made with wired LAN. However, confirm to your system admi
ページ11に含まれる内容の要旨
Using Web Browser Accessing from the Web browser Activate the Web browser in the personal computer. 1 Enter the IP address set by the projector into the URL input field of the Web 2 browser. Enter your “User name” and “Password”. 3 The factory default settings are user1 (user privileges) or admin1 (administrator privileges) for the use name and panasonic (lowercase letters) for the password. Click [OK] to display the Projector status 4 page. “Projector status” page is displayed. Avoid a
ページ12に含まれる内容の要旨
Using Web Browser (continued) Description of each item 1 2 3 4 5 6 1 4 Page selection tabs Detailed set up button Click this item to display the advanced settings page. Click these to switch pages. 5 Change password button 2 Monitor information button Click this item, and the status of the projector is Click this button to display the password change displayed. page. 3 6 Projector control button Language switch button Click this item to display the projector control Click
ページ13に含まれる内容の要旨
Using Web Browser (continued) Error information page If [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen, click the part to display the details of the error. • Depending on the nature of the error, the projector may be placed in the standby mode for its own protection. OK: Normal operation FAILED:Occurrence of trouble When [FAILED] has appeared for an item Parameter Description MAIN CPU BUS Trouble has occurred in the microcompute
ページ14に含まれる内容の要旨
Using Web Browser (continued) Network status page Displays the current configuration information of the network. Displays the configuration details of wired LAN. Basic control page To move from another page, click [Projector control], then [Basic control]. 1 2 3 4 1 3 Power On/Off control Switches image mode 2 4 Use these to select the input signals Turn on or off the Shutter function 14
ページ15に含まれる内容の要旨
Using Web Browser (continued) Detail control page Click [Projector control], then [Advanced control] to display the Detail control page. 1 2 3 4 1 2 Execute Auto setup function Operations on Image adjust 3 Operations on Screen mode 4 Operations on Rear/Ceiling 5 6 7 8 5 6 Operations on Keystone function Operations on Lens shift
ページ16に含まれる内容の要旨
Using Web Browser (continued) Change Password page Click [Change password]. 1 Administrator 2 User 1 2 Administrator mode 1 1 Account 2 2 Cur r e n t us e r na m e i np u t fi e l d 3 3 Cur r e n t pas s w o r d i np u t fi e l d 4 4 N e w us e r na m e i np u t fi e l d 5 5 N e w p as s w o r d i np u t fi e l d 6 6 N e w p as s w o r d i np u t fi e l d ( r e - e n t e r f o r c o n fi r m a t i o n ) 7 7 B u t t o n f o r e x e c u t i n g p as s w o r d c h a n g e User ac
ページ17に含まれる内容の要旨
Using Web Browser (continued) Network config page You can make detail network settings on projector, when connecting without the administrator authority or when connecting through an access point (infrastructure mode). LAN settings Click [Detailed set up] in the menu. 1 Select the items to change and click [Next]. 2 The settings window appears, showing the current settings. To change the LAN settings, click [Change]. To return to the previous window, click [Back]. Complete the detailed sett
ページ18に含まれる内容の要旨
Using Web Browser (continued) Ping test page This page makes it possible to check whether the network is connected to the e-mail server, POP server, DNS server, etc. Click [Detailed set up], then [Ping test] to display the Ping test page. Display which appears when the connection was successful. 1 2 Display which appears when the connection failed. 1 Enter the IP address of the server to be tested. 2 Button for conducting the test. 18
ページ19に含まれる内容の要旨
Using Web Browser (continued) E-mail setup page With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be sent to one or more preset e-mail addresses (maximum two addresses). Click [Detailed set up], then [E-mail set up] to display the E-mail setup page. 1 2 3 4 5 6 1 5 Select ENABLE to use the e-mail function. The user can modify the minimum time interval of temperature warning mail. The default value 2 Enter the IP address or server n
ページ20に含まれる内容の要旨
Using Web Browser (continued) E-mail setup page (continued) 1 2 1 Enter the E-mail Address2 of your desired recipient. 2 Select the conditions for sending e-mail. MAIL CONTENTS: Select [NORMAL] or [SIMPLE]. ERROR: An error is detected by self-diagnosis. LAMP 1-4 RUNTIME: Remaining lamp service time has reached the value set in the field. INTAKE AIR TEMPERATURE: Intake air temperature has reached the value set in the field. Authentication set up page The POP/SMTP server is set on this page