ページ1に含まれる内容の要旨
GEAppliances.com
Safety Instructions . . . . . . . . . . .2
Owner’s Manual and
Installation Instructions
Operating Instructions
Controls—Dip Switches . . . . . .3–5
Heat/Cool and
Controls—Terminal
Heat Pump Models
Connections . . . . . . . . . . . . . .6, 7
7500 Series
On/Off Switch . . . . . . . . . . . . . . .8
Ventilation Control . . . . . . . . . . .8
Care and Cleaning
Air Filters . . . . . . . . . . . . . . . . . . .9
Base Pan . . . . . . . . . . . . . . . . . . .9
Exhaust Coils . . . .
ページ2に含まれる内容の要旨
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock, or to prevent property damage, personal injury, or loss of life. SAFETY PRECAUTIONS n This Zoneline must be properly installed in accordance with the Installation Instructions before it is used. See the Installation Instructions in the back of this manual. n Immediately repair or replace all electric service cor
ページ3に含まれる内容の要旨
Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Customer Service Controls–dip switches. GEAppliances.com Controls–Dip Switches The dip switch controls are located behind the Dip front case panel, through an opening on the Switches front of the unit. To access the dip switches, remove the front case panel by removing the filter, taking out the four front screws, the upper two screws from the top of the panel and the shipping screws on each side, if present. (Di
ページ4に含まれる内容の要旨
ページ5に含まれる内容の要旨
ページ6に含まれる内容の要旨
ページ7に含まれる内容の要旨
ページ8に含まれる内容の要旨
Other features of your Zoneline. On/Off Switch The unit on/off switch is located on the front of the Zoneline. To turn the unit on, press the top of the switch in. To turn the unit off, press the bottom of the ON/OFF switch in. switch Ventilation Control The ventilation control lever is located on the left side of the Zoneline unit, behind the front case panel. To access the ventilation control lever, remove the front panel by removing the filter, taking out Open the four front screws, the upp
ページ9に含まれる内容の要旨
Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Care and cleaning. GEAppliances.com Turn the Zoneline off and disconnect the power supply before cleaning. Indoor/Outdoor Coils The exhaust coils on the Zoneline should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned by your GE service center. You will need to remove the unit from the case to inspect the coils because the dirt build-up occurs on
ページ10に含まれる内容の要旨
Installation Zoneline Air Instructions Conditioners Questions? Visit our Website at: GEAppliances.com or call 800.GE.CARES (800.432.2737). BEFORE YOU BEGIN IMPORTANT ELECTRICAL Read these instructions completely and carefully. SAFETY–READ CAREFULLY • IMPORTANT Save these – CAUTION: instructions for local inspector’s use. • All electrical connections and wiring MUST be • installed by a qualified electrician. IMPORTANT Observe all – governing codes and ordinances. • Follow the National Electrical
ページ11に含まれる内容の要旨
Installation Instructions ELECTRICAL REQUIREMENTS • Use ONLY the wiring size recommended for single FOR 230/208 VOLT POWER CORD outlet branch circuit. CONNECTIONS ONLY • Use ONLY the the type and size fuse or HACR 1. Remove the front panel by taking out the four circuit breaker indicated on the unit’s rating plate. front screws, the upper two screws from the top Proper current protection is the responsibility of of the panel and the shipping screws on each the owner. side, if present. (Discard
ページ12に含まれる内容の要旨
ページ13に含まれる内容の要旨
Installation Instructions DIRECT CONNECT APPLICATIONS 3 MAKE WIRE LEAD CONNECTIONS INSIDE THE JUNCTION BOX 1. Make all wire connections by using appropriate UL-listed electrical connectors and techniques. 4-Conductor Branch Circuit 3-Conductor Branch Circuit When connecting the Zoneline to a 4-conductor When connecting the Zoneline to a 3-conductor circuit: circuit: Connect the white and black leads of the Zoneline to Connect the white and black leads of the Zoneline to the branch circuit L1 an
ページ14に含まれる内容の要旨
Installation Instructions ZONELINE COMPONENTS Case Zoneline unit Front Case Panel REQUIRED ACCESSORIES (Check the “Essential Elements” label on the unit.) Cutout Dimensions: 1 20† W x 32 ⁄4† H Wall Plenum 3 RAVWP6 - 6† D x 19 ⁄4† W x 32† H 3 RAVWP8 - 8† D x 19 ⁄4† W x 32† H Architectural Louver 3 RAVWP12 - 12† D x 19 ⁄4† W x 32† H RAVAL1 3 RAVWP15 - 15† D x 19 ⁄4† W x 32† H 30† Cutout Cutout 1 Dimensions: 22 ⁄2† Dimensions: 3 3 20 ⁄8† W x 20 ⁄8† H 28† W x 48† H 50† Access Panel with Return Ai
ページ15に含まれる内容の要旨
ページ16に含まれる内容の要旨
Installation Instructions UTILITY CLOSET CONNECTION LOCATIONS IMPORTANT: Plan and locate plenum, wall plug, drain and thermostat carefully to avoid interference. Hard-to-reach locations will make installation and service difficult! Flex duct may be used Reference Dimensions for transitions only Use rigid duct for 90° 1 A Thermostat cable: 9 ⁄2¢ long bends and tees B Power cord: 60† long Outside wall 1 C Case width and depth: 23 ⁄8† D Case height: 31† E Condensate drain: 3/4† connector 1 (Cente
ページ17に含まれる内容の要旨
ページ18に含まれる内容の要旨
Installation Instructions WALL PLENUM AND ARCHITECTURAL LOUVER INSTALLATION • Install the appropriate wall plenum through the exterior wall in accordance with the Installation Instructions provided with the plenum. IMPORTANT: The wall plenum is not designed to carry structural loads. Proper wall header construction is required. The plenum requires proper flashing, shim and caulk for a weather resistant installation. Proper header for structural support. Apply proper caulking and flashing. Proper
ページ19に含まれる内容の要旨
ページ20に含まれる内容の要旨