Confidential CONFIDENTIALITY AGREEMENT BY USING THIS DOCUMENT, YOU AGREE TO ABIDE BY THE TERMS OF THIS AGREEMENT. PLEASE RETURN THIS DOCUMENT IMMEDIATELY IF YOU DO NOT AGREE TO THESE TERMS. 1. This document contains confidential, proprietary information of Seiko Epson Corporation or its affiliates. You must keep such information confidential. If the user is a business entity or organization, you must limit disclosure to those of your employees, agents and contractors who have a need to know a
ページ3に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential Revision Information Revision Page Altered Items and Contents Rev. A All Rev. B 1-6 Ethernet interface specification is added. 1-18~1-20 Ethernet interface specification is added. 2-2~2-4 Description of Waterproof is added. 3-1,3-3 The internal buzzer specification is added. 4-7~4-10 Description of DirectIO in OPOS is aded AppendixC Newly added. i
ページ4に含まれる内容の要旨
Confidential Key to Symbols The following symbols are used in the documentation for this product. See the specific warnings and cautions at appropriate points throughout this guide. WARNING: Warnings must be followed carefully to avoid serious bodily injury. CAUTION: Cautions must be observed to avoid minor injury to yourself, damage to your equipment, or loss of data. Note: Notes have important information and useful tips on the operation of the product. Safety Precautions This section prese
ページ5に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential Do not modify the power cord. Do not place heavy objects on the power cord. Do not bend, twist, or pull the power cord excessively. Do not route the power cord near heaters. Remove any dirt or dust from the power plug before plugging it in. Be sure to fully insert the power plug. CAUTION: ❏ All cables are to be connected only as described in the manual. Incorrect connection could cause damage or a fire hazard. ❏ Be sure to set this product on a
ページ6に含まれる内容の要旨
Confidential Moduler Connector Use the moduler connector specifically designed for the cash drawer for this product. Do not connect a telephone line to the drawer kick-out connector. About This Guide This guide is intended to provide all information necessary for system planning, design, installation and application of the TM-U230 for designers and developers of POS systems. Related Software and Documents Software/document name Description TM-U230 User’s Manual Provides instructions for oper
ページ7に含まれる内容の要旨
Developer’s Guide Confidential developer’s guide TM-U230 Revision Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Key to Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii Precautions in handling the fine coating of the case (only for
ページ8に含まれる内容の要旨
Confidential GS V (Function C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Notes on Using GS V Function C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 The usage of DirectIO in OPOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Contorol of The Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Appendix A Specifications
ページ9に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential Chapter 1 Installation Installation and Positioning of TM-U230 Precautions in Handling the Fine Coating Case (only for Fine Coating Case model) This printer is housed in a plastic case (*) with a fine coating; simple cleaning is enough to enable dirt to come off easily so that the exterior of the printer remains in good condition. Like plastic cases, handle the fine coating with care as described below. (*)Fine coating is not applied to the installation
ページ10に含まれる内容の要旨
Confidential External Dimensions See the External Appearance section in Appendix A. Vertical installation Horizontal installation Desk installation ❏ Wall mounting Use the optional wall mounting bracket (Model Name: WH-10) when the printer is to be wall mounted. When the printer is wall mounted, adjust the N.E. detector in the same way as for vertical installation. The power supply box can be attached below the printer if necessary. Wall-mounted installation 1-2 Installation
ページ11に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential Dip Switch Settings Make DIP switch settings according to the following procedures. 1. Remove the circuit board plate. circuit board plate 2. Set the DIP switches. Installation 1-3
ページ12に含まれる内容の要旨
Confidential Serial Interface DIP Switch 1 Switch No. Function On Off Default 1 Data receive error Print "?" Off Ignored 2 Receive buffer 1KB 16KB Off capacity 3 Handshaking XON/XOFF DTR/DSR Off 4 Word length 7 bit 8 bit Off 5 Parity check Yes No Off 6 Parity selection Even Odd Off 7 Baud rate selection 4800 bps 9600 bps Off 8 BUSY condition Receive buffer-full Offline Off Receive buffer-full DIP Switch 2 Switch No. Function On Off Default 1 Selects number of 42 cpl//35 cpl 40 cpl/33 cpl Off cha
ページ13に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential Parallel Interface DIP Switch 1 Switch No. Function On Off Default 1 Auto line feed Disabled Off Enabled 2 Receive buffer 1KB 16KB Off 3 - 7 Undefined -- -- Off 8 Busy condition Receive buffer-full Offline Off Receive buffer-full DIP Switch 2 Switch No. Function On Off Default 1 Selects number of 42 cpl//35 cpl 40 cpl/33 cpl Off characters per line (cpl) (7 × 9 font/9 × 9 font) 2 For internal use only (*1) Enabled Disabled On (autocutter) 3 Undefined -- --
ページ14に含まれる内容の要旨
Confidential Ethernet Interface DIP Switch 1 Switch No. Function On Off Default 1 Auto line feed Disabled Off Enabled 2 Receive buffer 1KB 16KB Off 3 - 7 Undefined -- -- Off 8 Busy condition Receive buffer-full Offline Off Receive buffer-full DIP Switch 2 Switch No. Function On Off Default 1 Selects number of 42 cpl//35 cpl 40 cpl/33 cpl Off characters per line (cpl) (7 × 9 font/9 × 9 font) 2 For internal use only (*1) Enabled Disabled On (autocutter) 3 Undefined -- -- Off 4 Pin 31 reset signal
ページ15に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential Settings for Horizontal Installation Perform the following procedures when the printer is to be used in a horizontal installation. Changing the Location of the Rubber Feet Remove the rubber feet from the bottom of the printer and attach them to the back of the printer. attach Remove Installation 1-7
ページ16に含まれる内容の要旨
Confidential Changing the Orientation of Near End Sensor Perform the following procedures to change the orientation of the near end sensor. 1. Place the printer horizontally and open the roll paper cover. 2. Use a coin to loosen the near end adjustment screw. 3. Turn the protrusion on the near end holder to change the position of the near end lever. 4. Tighten the near end adjustment screw, check that the near end sensor lever operates normally and close roll paper cover. Roll paper cover nea
ページ17に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential Attaching Switch Panel for Horizontal Installation 1. Clean the switch panel attached to roll paper cover. Note: Do not touch the switch panel surface after cleaning. Touching this surface may lower the strength of the adhesive. 2. Remove the seal covering the adhesive surface of the switch panel for horizontal installation. Note: Do not touch the adhesive surface of the switch panel for horizontal installation. Touching this surface may lower the strengt
ページ18に含まれる内容の要旨
Confidential Attaching the Power Supply Box (only for models with exclusive power supply unit) The location of the power supply box varies with the method of installation. WARNING: Use only AC adapter designated by EPSON. Using a non-standard power supply may cause a fire or shock hazard. When you are using an EPSON AC power supply or the equivalent, immediately turn off the printer and disconnect the power plug when you notice an abnormality. CAUTION: Always disconnect the power plug from the
ページ19に含まれる内容の要旨
TM-U230 Developer’s Guide Confidential 2. Put on the lower adapter cover with the cable through the notch in the lid and tighten the screws. In doing so, pull out the DC power supply cable from the DC power supply cable exit in the lower adapter cover so that around 15 cm of the cable protrudes from the cover. 3. Secure the covers with the screws packed with the printer (C.P.T-B Screw, 3 × 12, F/Zn). Pull out around 15 cm of the power cable Screws Lower adapter cover notch Power supply box a
ページ20に含まれる内容の要旨
Confidential 3. Attach the power supply box to the rear of the printer, aligning the box inside the rubber pads and secure with two screws packed with the printer (C.P.T-B Screw, 3 × 14, F/Ni). Holes 2 Holes 1 Screws Rubber pads Horizontal Installation and Wall Mounting 1. Check that the printer POWER switch is off and that the power supply cord of the AC adapter is not plugged into the wall outlet. 2. Connect DC power supply cable of the AC adapter to the DC connector on the printer. 1-12 I