Model Number: SU12000RT4U
SmartOnline 12kVA On-Line Double-Conversion UPS, 8U Rack/Tower, 208/120V or 240/120V Hardwire & NEMA
outputs, Split phase input
Highlights
12kVA / 12,000VA / 8400W on-line double-conversion UPS
208/120V or 240/120V +/-3% output at 60Hz
8U Rack / Tower compatible; Hot-swappable power and battery modules
USB, RS232 & EPO ports; support for SNMP/WEB card op
ページ2に含まれる内容の要旨
Supports connected equipment during blackouts for 20/7 minutes at half/full load levels, runtime is further expandable with optional external BP192V18-4U battery packs Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232 and dry contact messaging. HID-compliant USB interface enables integration with built
ページ3に含まれる内容の要旨
Output circuit breaker 20A branch rated double pole breakers (x3) protect 2 C19 and 1 5-15/20R outlets each, 30A branch rated double pole breakers (x2) protect 1 L6-30R outlet each, 20A single pole breakers (x2) protect one 5-15/20R outlet each Output AC waveform Sine wave (AC mode) Output AC waveform Pure Sine wave (battery mode) INPUT Rated input current (at 50A maximum load) Nominal Input 208V AC / 120V AC (4 wire split single phase); 240V AC /120V AC (4 wire split single phase) Voltage(s) Su
ページ4に含まれる内容の要旨
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement SURGE / NOISE SUPPRESSION UPS AC suppression Instantaneous response time EMI / RFI AC noise Yes suppression PHYSICAL Installation form 4 post 19 inch rackmount (mounting rail kit included) factors supported with included accessories Included mounting 2 sets of
ページ5に含まれる内容の要旨
Included battery pack 108.5 weight (kg) UPS Shipping 45.5 x 23.5 x 34.3 dimensions (height x width x depth / inches) UPS Shipping 115.6 x 59.7 x 87.1 dimensions (height x width x depth / cm) Shipping weight (lbs) 448.8 Shipping weight (kg) 203.8 Cooling method Fan UPS housing material Steel ENVIRONMENTAL Operating +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. Temperature Range Storage Temperature +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. Range Relative Humidity 0 t
ページ6に含まれる内容の要旨
High voltage transfer 140V (L1-N:L2-N) to battery power (setpoint) SPECIAL FEATURES Cold Start (startup in Cold-start operation supported battery mode during a power failure) High availability UPS Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; features Hot swappable batteries Green & high High efficiency economy mode operation; Schedulable daily hours of economy mode operation efficiency features CERTIFICATIONS UPS Certifications Tested
ページ7に含まれる内容の要旨
PDUMV30HVNET Single-Phase Switched PDU, 30A 208/240V, 0U Vertical Rackmount, C13 & C19 outlets, 1 NEMA L6-30P input plug AS400CABLE KIT Power Management Tools - UPS Communication Cable Kit for System i / AS400 / 1 iSeries Servers MODBUSCARD For remote monitoring and control via MODBUS protocol 1 P036-006 6-ft. 12AWG Heavy Duty Power cord (IEC-320-C19 to IEC-320-C20) 1 P041-001-2 1-ft. 10AWG Heavy Duty Power Splitter Cable (NEMA L6-30P to 2x NEMA L6-30R) 1 More information, including related pr