ページ1に含まれる内容の要旨
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU750RTXLCD2U
SmartOnline .75kVA On-Line Double-Conversion UPS, 2U Rack/Tower, Interactive LCD display,
100/110/120/127V NEMA outlets
Highlights
750VA / .75kVA / 675W on-line double-conversion 2U rack / tower UPS
100/110/120/127V 50/60Hz output; High efficiency economy mode option
Interactive LCD with 9 selectable screens of UPS and site power data
Expandable runtime, H
ページ2に含まれる内容の要旨
4 post installation hardware included, Optional 2POSTRMKITWM enables 2 post rack / wallmount installation, Optional 2-9USTAND enables tower placement Single line TEL / Network surge suppression Electronic bypass maintains utility output during a variety of UPS fault conditions Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement Frequency regulation / conversion mode offers generat
ページ3に含まれる内容の要旨
Built-in Two switchable single-outlet 5-15R load banks controllable switched load banks Output AC Pure Sine wave waveform (AC mode) Output AC Pure Sine wave waveform (battery mode) INPUT Rated input 8A current (at maximum load) Nominal Input 100V AC; 110V AC; 115V AC; 120V AC; 127V AC Voltage(s) Supported Nominal input 120V factory default voltage description UPS input 5-15P connection type Input circuit 15A breaker UPS Input cord 10 length (ft.) UPS Input cord 3 length (m) Recommended 15A 120V
ページ4に含まれる内容の要旨
Battery Hot-swappable, user replaceable batteries replacement description VOLTAGE REGULATION Voltage regulation Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and description overvoltages Overvoltage Corrects overvoltages to 150V (0-100% load) correction Undervoltage Corrects undervoltages to 100V at full load (90V at 100V nominal) correction Severe Corrects brownouts to 70V (70% load) & 55V (33% load) undervoltage correction LEDS ALARMS & SW
ページ5に含まれる内容の要旨
UPS / Power 8.9 x 44.4 x 31.8 Module dimensions in primary form factor (height x width x depth / cm) Installed whole 2U system total rack space height (rack spaces) Secondary form Tower (requires 2-9USTAND) factor UPS / Power 27.6 Module weight (lbs) UPS / Power 12.5 Module weight (kg) UPS Shipping 9.5 x 20 x 24 dimensions (height x width x depth / inches) UPS Shipping 24.1 x 50.8 x 61 dimensions (height x width x depth / cm) Shipping weight 40.1 (lbs) Shipping weight 18.2 (kg) UPS housing Steel
ページ6に含まれる内容の要旨
Communications USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface interface Network Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure monitoring port communications description PowerAlert Included software Communications USB and DB9 cabling included cable WatchDog Supports Watchdog application, OS and hard-reboot restart options for remote applications compatibility LINE / BATTERY TRANSFE
ページ7に含まれる内容の要旨
BP24V70-3U BP24V70-3U - External Battery Pack for UPS System 1 PDUB15 Single-Phase Hot-Swap PDU, 15A 120V, 2U Horizontal Rackmount, NEMA 5-15R 1 outlets, set of 2 NEMA 5-15P input plugs PDUMH15AT Single-Phase Auto Transfer Switch / Metered PDU, 15A 120V, 1U Horizontal 1 Rackmount, NEMA 5-15R outlets, 2 NEMA 5-15P inputs PDUMNV15 Single-Phase Monitored PDU, 15A 120V, 0U Vertical Rackmount, NEMA 5-15R outlets, 1 NEMA 5-15P input plug PDUMV15 Single-Phase Metered PDU, 15A 120V, 0U Vertical Rackm