SmartOnline 5kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 208/120V NEMA outlets
Highlights
5kVA / 5000VA / 4500 watt on-line double-conversion UPS; 0.9 power factor
208/120V 60Hz output; high efficiency economy mode option
6U Rack/Tower compatible; Hot swappable battery modules
USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card
optio
ページ2に含まれる内容の要旨
Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system in a 6U rack/tower configuration (4U UPS power module with internal batteries + 2U step-down transformer) Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions L6-30P input plug, plus 2 L6-30R, 2 L6-20R and 12 5-
ページ3に含まれる内容の要旨
Frequency 60 Hz compatibility Frequency Output frequency regulation +/- 0.05Hz (free running) compatibility details Output voltage +/- 2% regulation (line mode) Output voltage +/- 10% regulation (Economy line mode) Output voltage +/- 2% regulation (Battery mode) Built-in UPS output 12 5-15/20R outlet(s); 2 L6-20R outlet(s); 2 L6-30R outlet(s) receptacles Output circuit breaker High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 3 5-1
ページ4に含まれる内容の要旨
Replacement battery RBC5-192 (qty 1) cartridge (internal UPS battery replacement) Battery Access Front panel battery access door Battery replacement Hot-swappable, user replaceable batteries description VOLTAGE REGULATION Voltage regulation Online, double-conversion power conditioning description Overvoltage correction 2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less) Undervoltage 2% output voltage regulation during undervoltages to 156V (full load) /
ページ5に含まれる内容の要旨
Installed whole 20.75 system maximum rack depth (inches) Installed whole 52.7 system maximum rack depth (cm) Installed whole 6U system total rack space height (rack spaces) Secondary form factor Tower UPS / Power Module 113.6 weight (lbs) UPS / Power Module 51.6 weight (kg) Stepdown transformer 3.5 x 17.5 x 20.75 dimensions (height x width x depth / inches) Stepdown transformer 8.8 x 44.4 x 52.7 dimensions (height x width x depth / cm) Stepdown transformer 76 weight (lbs) Stepdown transformer 34
ページ6に含まれる内容の要旨
AC economy mode 96% efficiency rating (100% load) Operating Elevation (ft) 0 to 6560 ft. / 0 to 2000 m Audible Noise 65 dB at 1m front side Operating Elevation 0-2000 m (m) COMMUNICATIONS Communications USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface interface Network monitoring Two contact closure monitoring options available - RELAYIOCARD with six configurable contact closure outputs port description (uses UPS card slot) and RELAYIOMINI with 3 configurable
ページ7に含まれる内容の要旨
Related Model Description Qty. BP192V12-3U BP192V12-3U - External Battery Pack for UPS System 1 2-9USTAND Enables Tower Placement of Rackmount UPS Systems 1 SNMPWEBCARD For remote monitoring and control via SNMP, Web, or Telnet. 1 ENVIROSENSE Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD 1 or switched PDU.) RELAYIOMINI 3 Relay I/O Mini-module 1 RELAYIOCARD Programmable Relay I/O Card 1 AS400CABLEKIT2 Power Management Tools - UPS Communication Cable Kit for Sys