ページ1に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 1
Owner’s Manual
®
SmartPro Rackmount
Intelligent, Line-Interactive UPS Systems
SMX500RT1U SMX750RT1U SMX1000RT2U
SMX1500XLRT2U SMX3000XLRT2U
• 230V Sine-Wave Input/Output 500VA - 3000VA Capacities
Extended-Run Options*
* SMX1500XLRT2U and SMX3000XLRT2U models
Important Safety Instructions 2
Mounting 3
Quick Installation 5
Optional Installation 6
Basic Operation
7
Storage and Service 11
Battery Replace
ページ2に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 2 Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty. UPS Location Warnings • Use caution when lifting your UPS. Because of the considerable weight of all rackmount UPS systems, at least two people should assist in liftin
ページ3に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 3 Mounting (Rack) Mount your equipment in either a 4-post or 2-post rack or rack enclosure (see next page for 2-post mounting). The user must determine the fitness of hardware and procedures before mounting. If hardware and procedures are not suitable for your application, contact the manufacturer of your rack or rack enclosure. The procedures described in this manual are for common rack and rack enclosure types and may n
ページ4に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 4 Mounting (Rack) continued 2-Post (Telecom) Mounting Mount 1U UPS models in 2-post racks with user-supplied hardware following the procedure below. If you mount 2U UPS models in 2-post racks, they require the addition of a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTRMKIT, sold separately). See Installation Kit owner’s manual for installation procedure for 2U UPS models. A Attach mounting ears to the front
ページ5に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 5 Quick Installation 1 Unplug computer’s power cord from both AC outlet and computer’s AC input. 1 IEC320-C14 plug shown A Insert the female plug of com- 2 A puter’s cord into UPS’s AC input. Insert the male plug of computer’s cord into AC outlet.* NOTE! after you plug the UPS into a live AC outlet, the UPS (in “Standby” mode) will automatically charge its batteries,** but will not supply power to its outlets until it is
ページ6に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 6 Optional Installation These connections are optional. Your UPS will function properly without these connections. Note: SMX3000XLRT2U shown in all diagrams. 1 USB and RS-232 Serial Communications (all models) 1a Use the included USB cable (see ) and/or DB9 serial 1a 1b cable (see ) to connect the communication port on your computer to the communication port of your UPS. Install on your computer the Tripp Lite PowerAlert
ページ7に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 7 Basic Operation Buttons (Front Panel) “ON/OFF/STANDBY” Button • To turn the UPS ON: with the UPS plugged into a live AC wall outlet*, press and hold the “ON/OFF/STANDBY” button for one second.** Release the but- ton. If utility power is absent, you can “cold-start” the UPS (i.e.: turn it ON and supply power for a limited time from its batteries***) by pressing and holding the “ON/OFF/STANDBY” button for one second.** •
ページ8に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 8 Basic Operation continued Indicator Lights (Front Panel) All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON. “POWER” LED: this green LED lights continuously when the UPS is ON and supplying connected equipment with AC power from a utility source. The LED flashes and an alarm sounds (4 short beeps followed by a pause) to indicate the UPS is operating from its internal batterie
ページ9に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 9 Basic Operation continued Other UPS Features (Rear Panel) AC Receptacles: Your UPS features IEC320-C13 outlets, and select models also feature IEC320-C19 outlets. These output receptacles provide your con- nected equipment with AC line power during normal operation and battery power during blackouts and brownouts. The UPS protects equipment connected to these receptacles against damaging surges and line noise. If you ha
ページ10に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 10 Basic Operation continued Accessory Slot: Remove the small cover panel from this slot to install optional accessories to remotely monitor and control your UPS. Refer to your accessory’s manual for installation instructions. Contact Tripp Lite Customer Support at (773) 869-1234 for more information, including a list of available SNMP, network management and connectivity products. Power Sensitivity Adjustment (Select Mod
ページ11に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 11 Storage and Service Storage Before storing your UPS, turn it completely OFF: with the UPS ON and receiving utility power, press and hold the “ON/OFF/STANDBY” button for one second (an alarm will beep once briefly after the interval has passed); then, unplug the UPS from the wall outlet. If you store your UPS for an extended period of time, recharge the UPS batteries once every three months: plug the UPS into a wall out
ページ12に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 12 Battery Replacement Under normal conditions, the original batteries in your UPS will last many years. See Safety section before replacing batteries. The batteries are designed for hot-swap replacement (i.e. leaving the UPS in ON mode), but qualified service personnel may wish to put the UPS in the OFF mode before proceeding. 1U UPS Models 2U UPS Models Procedure 1 Remove Front Panel 2 Disconnect Batteries 1 6 1 6 3 Rem
ページ13に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 13 Manual del propietario ® SmartPro Rackmount Sistemas de UPS Inteligentes e Interactivos en Línea SMX500RT1U SMX750RT1U SMX1000RT2U SMX1500XLRT2U SMX3000XLRT2U 230V Onda Senoidal Entrada/Salida Capacidades de 500VA - 3000VA Opciones de Operación Extendidas* * Modelos SMX1500XLRT2U y SMX3000XLRT2U Instrucciones de seguridad importantes 14 Montaje 15 Instalación rápida 17 Instalación opcional 18 O
ページ14に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 14 Instrucciones de seguridad importantes GUARDE ESTAS INSTRUCCIONES Este manual contiene importantes instrucciones que deben seguirse durante la instalación, operación y el almacenamiento de todos los UPS de Tripp Lite. La no observancia de estas advertencias anulará su garantía. Advertencias sobre la ubicación del UPS • Tenga cuidado al levantar el UPS. Debido al gran peso de los UPS para montaje en bastidor, se requier
ページ15に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 15 Montaje (Bastidor) Monte su equipo en un bastidor de 2 o 4 postes (vea la siguiente página para información sobre el montaje de 2 postes). El usuario debe determinar la idoneidad de los materiales y accesorios, así como de los procedimientos antes del montaje. Si los materiales y procedimientos no son adecuados para su aplicación, contacte con el fabricante de su bastidor. Los procedimientos descritos en este manual so
ページ16に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 16 Montaje (en bastidor) continúa Montaje de 2 postes (Telecomunicaciones) Monte los modelos de UPS de 1U en bastidores de 2 postes usando los accesorios incluidos y siguiendo el pro- cedimiento indicado a continuación. Si monta un modelo de UPS de 2U en bastidores de 2 postes, necesitará agregar un kit de instalación para montaje en bastidor de 2 postes de Tripp Lite (modelo: 2POSTRMKIT, vendido por separado) Vea el manu
ページ17に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 17 Instalación rápida Desenchufe el cable eléctrico del 1 ordenador del enchufe de toma eléctrica C.A. y de la entrada C.A. del ordenador. A Inserte el enchufe hembra del cable 2 del ordenador en el dispositivo de entrada C.A. del UPS. Inserte el enchufe 1 macho del cable eléctrico del ordenador IEC320-C14 enchufe demostrado en el enchufe de toma eléctrica C.A.* NOTA Después de conectar el UPS en una toma de corriente
ページ18に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 18 Instalación opcional Estas conexiones son opcionales. Su UPS funcionará correcta- mente sin ellas. Nota: Modelo SMART3000RM2U mostrado en todos los diagramas. Comunicaciones USB y serie RS-232 1 (todos los modelos) 1a Use el cable USB incluido (vea ) y/o el cable serie DB9 1a 1b (vea ) para conectar el puerto de comunicaciones de su computadora al puerto de comunicaciones de su UPS. Instale en su computadora el softwar
ページ19に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 19 Operación básica Botones (Panel frontal) Botón “ON/OFF/STANDBY” (Encendido/Apagado/Reserva) • Para encender el UPS: Con el UPS conectado en una toma de CA con energía*, presione y mantenga presionado el botón “ON/OFF/STANDBY” (Encendido/Apagado/Reserva) por un segundo.** Suelte el botón. Si no hay energía de la red, puede “arrancar en frío”el UPS (es decir, encenderlo y suministrar energía de sus baterías por un tiemp
ページ20に含まれる内容の要旨
200407003 93-2259 SMARTPROINT Owners Manual.qxd 7/30/2004 11:56 AM Page 20 Operación básica (continúa) Luces indicadoras (Panel frontal) Todas las descripciones de luces indicadoras se aplican cuando el UPS está conectado en un tomacorriente y encendido. LED “POWER” (ALIMENTACIÓN): Este LED verde se enciende permanentemente cuando el UPS está encendido y proporcionando energía de CA al equipo conectado desde el suministro de red. El LED destella y una alarma suena (4 pitidos cortos seguidos d